Code of Practice for Design Loads (Other than Earthquake) for Buildings and Structures, Part 3: Wind Loads
1987 Edition

The 1987 edition of IS 875 Part 3 outlines the methodology for assessing wind loads on buildings and structures across India, excluding seismic considerations. It details the procedure to compute design wind pressures by taking into account factors such as terrain, topography, building form, and structural components, including gust influences and internal pressure effects. This code is vital for engineers and designers to ensure structural integrity against wind forces using Indian climatic and geographical data.

13Sections
195Clauses Indexed
AI Search Ready
1987Edition
Structural SafetyCategory
Alternative search terms: wind-load-design-guidelines-for-buildings-and-structures-1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 pdf free download, wind-load-design-guidelines-for-buildings-and-structures-1987 free download pdf, wind-load-design-guidelines-for-buildings-and-structures-1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987:1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987-1987 PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 (1987) PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 1987 edition PDF, wind-load-design-guidelines-for-buildings-and-structures-1987 edition 1987 PDF

What This Standard Covers

The 1987 edition of IS 875 Part 3 outlines the methodology for assessing wind loads on buildings and structures across India, excluding seismic considerations. It details the procedure to compute design wind pressures by taking into account factors such as terrain, topography, building form, and structural components, including gust influences and internal pressure effects. This code is vital for engineers and designers to ensure structural integrity against wind forces using Indian climatic and geographical data.

Who Uses This Standard

  • Structural design engineers
  • Civil engineering professionals
  • Architectural planners
  • Building design specialists
  • Wind impact analysts
  • Construction project engineers
  • Regulatory compliance officials

Key Topics Covered

Determination of fundamental wind speeds and pressures
Classification of terrain and its impact on wind profiles
Influence of topographical features on wind loads
Coefficients for forces and pressures on diverse building geometries
Calculation methods for wind loads on specific structural components
Internal versus external pressure coefficients for structures
Wind load considerations on various roof configurations including monoslope, pitched, curved, and hybrid types
Gust factor application and dynamic behavior of slender structures
Wind load provisions for specialized structures like grandstands and silos
Impact of openings on internal pressure coefficients
Reduction factors applicable to members of limited length
Design wind load calculation using the gust energy approach

Table of Contents

1Introduction and Scope
2Fundamental Wind Speed Determination
3Factors Related to Terrain and Elevation
4Topographical Influences on Wind Loads
5Profiles of Wind Pressure and Velocity
6Force and Pressure Coefficient Guidelines
7Wind Load Calculations for Buildings and Structures
8Dynamic Effects and Gust Factor Considerations
9Wind Load Analysis on Individual Structural Elements
10Internal Pressure Coefficient Application
11Wind Load Provisions for Special Structures and Roof Designs
12Procedural Guidelines for Wind Load Calculations
13Supplementary Appendices on Topographical Impacts and Illustrative Examples

Popular Questions About IS 875 PART 3

?What methodology does IS 875 Part 3 use to establish basic wind speeds?

Detailed answer not available.

?Which terrain categories are identified and how do they influence wind load computations?

Detailed answer not available.

?How are the internal and external pressure coefficients applied when buildings have openings?

Detailed answer not available.

?What are the recommended force coefficients for various structural members and roof configurations?

Detailed answer not available.

?In what way does the standard address gust effects and dynamic responses for slender structures?

Detailed answer not available.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 875 PART 3. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required