IS 1200 PART 141984AI Search Enabled✦ AI Generated

Method of measurement of building and civil engineering works, Part 14: glazing
1984 Edition

The 1984 edition of IS 1200 Part 14 defines a uniform approach for quantifying glazing tasks in building and civil engineering projects throughout India. It outlines procedures for measuring various glazing types such as plain, wired, and frosted glass, ensuring consistent practices for professionals involved in estimation, invoicing, and contract management of glazing-related construction activities.

18Sections
37Clauses Indexed
AI Search Ready
1984Edition
Methods of Measurement of Works of Civil EngineeringCategory
Alternative search terms: standardized-method-for-measuring-glazing-works-1984 PDF, standardized-method-for-measuring-glazing-works-1984 pdf free download, standardized-method-for-measuring-glazing-works-1984 free download pdf, standardized-method-for-measuring-glazing-works-1984 PDF, standardized-method-for-measuring-glazing-works-1984 PDF, standardized-method-for-measuring-glazing-works-1984 1984 PDF, standardized-method-for-measuring-glazing-works-1984:1984 PDF, standardized-method-for-measuring-glazing-works-1984-1984 PDF, standardized-method-for-measuring-glazing-works-1984 (1984) PDF, standardized-method-for-measuring-glazing-works-1984 1984 edition PDF, standardized-method-for-measuring-glazing-works-1984 edition 1984 PDF

What This Standard Covers

The 1984 edition of IS 1200 Part 14 defines a uniform approach for quantifying glazing tasks in building and civil engineering projects throughout India. It outlines procedures for measuring various glazing types such as plain, wired, and frosted glass, ensuring consistent practices for professionals involved in estimation, invoicing, and contract management of glazing-related construction activities.

Who Uses This Standard

  • Quantity Surveyors
  • Civil Engineering Professionals
  • Architectural Designers
  • Construction Contractors
  • Project Coordinators
  • Building Inspectors
  • Cost Estimation Specialists

Key Topics Covered

Measurement techniques for glass panes and sheet louvres
Glazing classification and categorization
Details and measurement of putty and fixing systems
Procedures for dimension booking and rounding
Measurement methods for circular and curved cuts
Counting and specification of drilled holes
Measurement of grinding, polishing, and edge finishing
Separate measurement protocols for wood, metal, and concrete works
Inclusion of handling and transportation in item descriptions
Use of decimal units and rounding conventions
Grouping of items for billing purposes
Measurement specifics for wired and frosted glass

Table of Contents

0Overview and Key Specifications for Measuring Glazing

IS 1200 Part 14 introduces the standardized approach for measuring glazing in construction and civil engineering projects. It specifies scope, material descriptions—including plain, wired (with wire pattern details), and frosted glass (noting frosting sides)—and mandates rounding off measurements according to IS 2:1960 to maintain precision to two decimal places (nearest 0.01 m²). This section also includes a summary table of measurement units and rounding standards, supported by a flowchart illustrating the steps for identifying glazing types and applying measurement rules.

1Scope of Glazing Measurement

This section defines the measurement scope for glazing in buildings and civil engineering works, emphasizing area calculation to the nearest 0.01 m² and rounding rules per IS 2:1960. It highlights the necessity for detailed Bills of Quantities that describe measurement methods, rounding procedures, and material/workmanship specifics, ensuring uniformity and accuracy in quantity take-off and billing.

2General Measurement Guidelines

General principles covering measurement of glazing include adherence to net measurements in decimal units, distinct treatment of different glazing materials (plain, wired with specified reinforcement pattern, frosted with frosting side details), and rounding conventions per IS 2-1960. A summary table and accompanying flowchart provide clarity on these foundational measurement rules.

2.1Grouping of Items for Measurement

This section outlines the criteria for clubbing measurement items, permitting grouping only when detailed descriptions match exactly. It clarifies that conveyance, handling, storage, and waste are considered inclusive in item descriptions, and emphasizes the importance of separate measurement for different materials such as wood, metal, and concrete. A summary table and decision flowchart facilitate understanding of item grouping protocols.

2.2Booking of Dimensions

Describes the procedure for recording dimensions, specifying the order of Length, Breadth/Width, and Height/Depth/Thickness. It mandates measuring pane dimensions by adding clear opening size to the rebate widths, handling non-rectangular panes via enclosing rectangle methods, and recording measurements to the nearest 0.01 m using the decimal system. A flowchart illustrates the dimension booking workflow.

2.3Item Descriptions for Measurement

Details the requirements for item descriptions encompassing conveyance, handling, storage, and waste unless otherwise noted. Differentiates glazing sheets by type (plain, wired, frosted) with specific notes on reinforcement patterns and frosting sides. Also covers enumeration of glass and louvres and conditions for item grouping, supported by a descriptive flow diagram.

2.4Measurement Units and Precision

Specifies all measurements are in the decimal system with lengths recorded to the nearest 0.01 m and areas to the nearest 0.01 m². Emphasizes net measurements taken post-installation and recommends use of calibrated tools. Includes a process flowchart summarizing measurement procedures.

2.5Preparation of Bills of Quantities

Explains the comprehensive detailing required in Bills of Quantities, including accurate material and workmanship descriptions, net decimal measurements, separate quantification for different materials, and adherence to rounding rules. Provides formulas for calculating quantities and a flow diagram illustrating the preparation process for planning and tendering.

2.6Measurement of Different Glazing Sheet Types

Focuses on separately measuring various glazing materials—plain, wired (with reinforcement details), frosted (noting single or double-sided frosting). Measurement is based on the visible area, calculated as length multiplied by breadth, rounded per IS 2:1960. A flowchart outlines the measurement steps.

2.7Separate Measurement for Different Material Types

Mandates distinct measurement for works involving wood, metal, concrete, etc., with area measurements recorded in square meters including specified thickness, rounded to 0.01 m². A tabular summary and flowchart highlight the measurement protocol to avoid mixing quantities.

2.8Classification of Glazing Types

Although IS 1200 Part 14 primarily addresses measurement methods, it implies classification based on glazing material types: clear glass, wired glass (with reinforcement patterns), frosted glass (specifying frosting side), and other sheets like acrylic or polycarbonate. Each type requires separate measurement and description, with rounding adherence. A classification table and diagram illustrate this categorization.

3Detailed Method of Measurement for Glazing

Outlines the step-by-step measurement procedures for glazing works, including measurement of glass areas, frames, beading, and putty. Emphasizes net measurements in decimal units, full descriptions in Bills of Quantities, and rounding rules. Includes formulas and a flowchart summarizing the measurement process from site installation to final quantification.

3.1Measurement Procedure for Glass Panes

Specifies measurement of glass panes by combining the clear opening dimensions with the width of rebates. For non-rectangular panes, the smallest enclosing rectangle is measured. Different glass types (plain, wired with wire pattern, frosted with frosting sides) must be distinctly described. Straight cutting is included in the measurement. A formula and flowchart provide calculation and recording guidance.

3.2Measurement of Circular and Curved Cuts

Circular and curved cuts in glazing are measured as additional quantities in running meters, calculated by the arc length formula (radius multiplied by central angle in radians). Dimensions are recorded to the nearest 0.01 m, with a flowchart illustrating the measurement steps for curved edges.

3.3Counting and Measurement of Glass and Sheet Louvres

Glass and sheet louvres must be separately enumerated and measured by their net visible glazed area. Descriptions include type of glass or sheet material, thickness, wire patterns, and frosting sides as applicable. Measurements are rounded according to IS 2:1960. A flow diagram clarifies the process.

3.4Measurement for Removal of Existing Glass

Removal of old or broken glass is measured in square meters. The type of glass must be specified, including wired or frosted details. Different glazing fixing methods (putty with sprigs or pins, putty with beads, rubber or velvet with beads) are to be described and measured separately. A tabular summary and flowchart outline the approach.

3.5Measurement and Enumeration of Drilled Holes

Each drilled hole in glazing is enumerated with details including hole diameter, glass type and thickness, and pane size. Measurements are recorded with precision to 0.01 m for linear dimensions and 0.01 m² for areas. The area of circular holes is calculated using the formula π × (diameter/2)². This ensures accurate billing and quality control.

3.6Measurement of Edge Finishing: Grinding, Polishing, and Rounding

Grinding, polishing, and rounding of glass edges are measured in running meters along the treated edges. Each finishing type must be clearly described before measurement. Separate descriptions are required for different glass types, including wired and frosted glasses with relevant details. A flowchart depicts the measurement process.

Popular Questions About IS 1200 PART 14

?What are the prescribed methods for measuring various glazing types under this standard?

IS 1200 Part 14 outlines measurement methods for glazing works by quantifying the visible glass surface area for each glazing type separately, including plain, wired, laminated, and toughened glass. Dimensions are recorded in square meters, and thickness and glass type must be documented. The standard mandates adherence to IS 2-1960 rounding rules to ensure precision.

?How should circular or curved cuts in glass be quantified according to the standard?

Circular and curved glass cuts are measured as additional quantities in running meters, calculated by determining the arc length along the curve using the radius and central angle. These lengths are recorded to the nearest 0.01 meter and treated as extras beyond straight cuts, ensuring accurate representation of curved glazing work.

?Does the standard provide instructions for measuring putty and fixing techniques used in glazing?

Yes, IS 1200 Part 14 specifies that measurement should account for different putty and fixing methods including front and back putty with sprigging or glazing pins, putty bedded with beads, and rubber or velvet bedded with beads. Each method and putty type must be described and measured separately, allowing clear classification and billing.

?How are drilled holes in glazing components enumerated and measured?

Each drilled hole must be individually counted and recorded with its diameter, type, and thickness of the glass or sheet, as well as the size of the pane containing it. Linear dimensions are measured to 0.01 meters, and areas to 0.01 square meters. This detailed enumeration ensures precise measurement and proper billing.

?What rounding conventions are followed when documenting measurements for glazing work?

Measurements must be rounded off in accordance with IS 2:1960 rules, maintaining the same number of significant figures as specified by the standard. This involves rounding down when the last digit is less than 5, rounding up when greater than 5, and rounding to the nearest even number when exactly 5, ensuring consistency and accuracy in measurement records.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 1200 PART 14. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required