IS 2556 PART 61995AI Search Enabled✦ AI Generated

Vitreous Sanitary Appliances (Vitreous China), Part 6: Specific Requirements of Urinals and Partition Plates
1995 Edition

This standard delineates precise specifications for vitreous china urinals and partition plates intended for sanitary applications. It includes details on design patterns, dimensions, construction quality, finishing, inspection protocols, marking, and cleanliness tests to guarantee hygienic and functional sanitary fixtures. This guideline is vital for manufacturers, architects, and engineers engaged in the fabrication, installation, and quality control of urinals and partition plates across India.

11Sections
71Clauses Indexed
AI Search Ready
1995Edition
Sanitary Appliances and Water FittingsCategory
Alternative search terms: requirements-for-vitreous-china-urinals-and-partitions-1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 pdf free download, requirements-for-vitreous-china-urinals-and-partitions-1995 free download pdf, requirements-for-vitreous-china-urinals-and-partitions-1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995:1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995-1995 PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 (1995) PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 1995 edition PDF, requirements-for-vitreous-china-urinals-and-partitions-1995 edition 1995 PDF

What This Standard Covers

This standard delineates precise specifications for vitreous china urinals and partition plates intended for sanitary applications. It includes details on design patterns, dimensions, construction quality, finishing, inspection protocols, marking, and cleanliness tests to guarantee hygienic and functional sanitary fixtures. This guideline is vital for manufacturers, architects, and engineers engaged in the fabrication, installation, and quality control of urinals and partition plates across India.

Who Uses This Standard

  • Manufacturers of sanitaryware
  • Civil engineering professionals
  • Plumbing system designers
  • Quality control inspectors
  • Public health engineering officers
  • Construction contractors
  • Facility upkeep supervisors

Key Topics Covered

Various urinal designs and dimensions
Size tolerances and measurements
Construction and surface finishing standards
Functional and connection-related dimensions
Procedures for cleanability testing
Labeling and certification guidelines
Types of urinals including flat-back, angle-back, and squatting plates
Specifications for partition plates
Installation and support methods
Material composition and glazing criteria
Sampling and inspection techniques
Compatibility with flushing cisterns

Table of Contents

1Scope

This section outlines the standard’s coverage of essential functional and connecting dimensions necessary for the design and interchangeability of vitreous china urinals and partition plates. It highlights critical clauses and corresponding tables and figures that define these dimensions, emphasizing adherence for optimal system performance.

2Reference Tables and Figures

Details key tables and figures, such as dimensional data for squatting plates (Table 3, Figure 6) and other fixtures (Tables 5 and 6, Figure 7). It stresses the significance of these references in ensuring ergonomic design and compatibility.

3General Specifications

Describes the general requirements including functional dimensions for various components, supported by tables and figures. It provides minimum size values and their locations on partition plates to guarantee proper fit and structural soundness.

4Design Patterns and Sizes

Covers the categorization of urinals by pattern and size, including flat back and angle back types with or without flushing rims. It provides detailed dimensional tables and explains fixing methods and hygienic preferences.

5Dimensions and Permissible Deviations

Specifies the tolerance limits for dimensions, referencing related parts of the standard for unspecified cases. It outlines the importance of following connecting and functional dimension tables for ensuring interchangeability and system integrity.

6Construction and Surface Finish

Details construction requirements and finishing standards for partition plates and bowl-pattern urinals, including dimensional specifications for different sizes and patterns to maintain quality and durability.

7Installation and Fixing Guidelines

Provides guidelines on fixing arrangements for urinals and partition plates, highlighting critical connecting dimensions and bracket placements that ensure structural stability and conformity with standard dimensions.

8Cleanability Testing Procedures

Describes the methodology for conducting cleanability tests using organic dye solutions and specified flushing volumes to verify the hygienic flushing performance of urinals and squatting plates, including acceptance criteria.

9Sampling and Quality Inspection

Outlines sampling plans and inspection procedures based on statistical methods from IS 9140:1995. It explains process and lot inspections to maintain quality consistency in production batches.

10Labeling and Certification Requirements

Explains marking obligations for manufacturers, including mandatory markings and the optional use of BIS certification marks under the Bureau of Indian Standards Act. It describes licensing and surveillance processes to ensure compliance.

Annex ACommittee Composition and Roles

Lists the members and their affiliations of the Sanitary Appliances and Water Fittings Sectional Committee responsible for this standard, emphasizing diverse representation from government, industry, research, and BIS.

Popular Questions About IS 2556 PART 6

?What are the standard dimensions and patterns for vitreous china urinals specified in this code?

The standard categorizes urinals by pattern—flat back or angle back—with options for flushing rims or rimless designs, across two main sizes. Heights range from 345 mm to 590 mm, with projections and widths varying accordingly; squatting plates are provided in two standard sizes as well. Rimless models are preferred for hygiene, and fixing can be side-mounted or top and bottom mounted. Detailed dimensions ensure compatibility and ease of cleaning as per the standard.

?How should the cleanability test for urinals be carried out according to the guidelines?

The cleanability test involves applying a 0.1% organic dye solution on the interior flushing surfaces of urinals mounted in their normal positions. For bowl urinals, a 2.5-litre flush is applied via an automatic cistern with a 12.5 mm bore spreader mounted at least 90 cm above. For squatting plates, the dye is applied below flush holes, followed by pouring 2.5 litres of water along these holes. The test passes only if no dye residue remains post-flushing, ensuring hygienic surfaces.

?What are the dimensional requirements and tolerances for urinal waste outlet holes?

Waste outlet holes for bowl pattern urinals without flushing rims must conform to specific dimensions: internal diameter of 45 ± 2 mm, outlet flange approximately 65 ± 5 mm, and depth not less than 20 mm. The distance from the back to the center of the outlet varies by urinal pattern, typically 100 mm for flat back and 150–225 mm for angle back models. Fixing holes of minimum 6.5 mm diameter are also specified to ensure secure installation and compatibility.

?What marking and certification practices are required for manufacturers under this standard?

Manufacturers are required to mark urinals and partition plates clearly and indelibly with their name or trademark and the batch or lot number. Additionally, use of the BIS Standard Mark is optional but regulated under the Bureau of Indian Standards Act, 1986. To use this mark, manufacturers must obtain a license from BIS, which includes ongoing surveillance and product conformity checks to uphold quality standards.

?Are there prescribed fixing arrangements for partition plates and urinals?

Yes, the standard specifies fixing methods for squatting plate urinals that include an integral longitudinal flushing pipe connected through three 13 mm diameter holes to the sump, ensuring that the installation height is maintained. Partition plates should be installed securely as illustrated in the relevant figures, guaranteeing stability and correct spacing. Deviations in patterns and sizes may be permitted with agreement, provided functional dimensions and other requirements are met.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 2556 PART 6. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required