IS 9492012AI Search Enabled✦ AI Generated

Emergency (Rescue) Tender - Functional Requirements

IS 949:2012 specifies the functional requirements for Emergency (Rescue) Tenders used by fire and rescue services. It covers detailed provisions on design, materials, construction, electrical systems, safety features, and equipment to ensure reliability and effectiveness during emergency operations. This standard is essential for manufacturers, engineers, and procurement professionals involved in the design, production, and evaluation of rescue vehicles tailored for fire and special service work.

15Sections
107Clauses Indexed
AI Search Ready
2012Edition
Fire FightingCategory
Alternative search terms: IS 949 PDF, IS 949 pdf free download, IS 949 free download pdf, IS949 PDF, IS-949 PDF, IS 949 2012 PDF, IS 949:2012 PDF, IS 949-2012 PDF, IS 949 (2012) PDF, IS 949 2012 edition PDF, IS 949 edition 2012 PDF

What This Standard Covers

IS 949:2012 specifies the functional requirements for Emergency (Rescue) Tenders used by fire and rescue services. It covers detailed provisions on design, materials, construction, electrical systems, safety features, and equipment to ensure reliability and effectiveness during emergency operations. This standard is essential for manufacturers, engineers, and procurement professionals involved in the design, production, and evaluation of rescue vehicles tailored for fire and special service work.

Who Uses This Standard

  • Fire Service Vehicle Manufacturers
  • Fire and Rescue Engineers
  • Procurement Officers in Fire Departments
  • Automotive Design Engineers
  • Safety Compliance Inspectors
  • Maintenance and Service Technicians
  • Emergency Response Planners

Key Topics Covered

Fuel system capacity and safety features
Electrical system design including alternators and battery charging
Structural design and materials for cab and superstructure
Stability and safety requirements under load and tilt conditions
Lockers and equipment storage with roller shutters
Cabin ergonomics and crew access
Lighting and signaling devices including fire signs and beacons
Corrosion protection and painting standards
Accessories such as ladders, grab rails, and sirens
Performance requirements including speed and acceleration
Wiring, fuses, and electrical circuit protection
Workmanship and finish quality
Instruction manuals and operational accessories

Table of Contents

1Scope

IS 949 Scope Summary: Schedule of Equipment for Fire Appliances

The scope defines the minimum equipment to be carried on fire appliances, adaptable to local conditions and chassis size.

Key Equipment & Quantities (Annex A Highlights)

ItemQuantity
Breathing apparatus (positive pressure, IS 10245 Part 2)6 sets
Protective suits (Proximity/chemical)4 Nos.
Ambu bags1 set
MFR Kit2 sets
Woolen blankets (IS 1681)6
Oxygen cylinder (spare, 5 litre)1
Leather gloves2 pairs
Chain lifting 5 t (6 m length)1 set
Chain tackle 2 t (pulley block)1 set
Tarpaulin (3.5 m × 3.5 m)2 Nos.
Hydraulic jacks (various capacities)Multiple Nos.
Fireman's axe (IS 703)2 Nos.
Hydraulic cutters and spreaders1 No. each
Wireless walkie-talkie sets6 sets
Thermal imaging camera1 No.

Referenced IS Standards for Equipment

  • IS 10245 (Part 2): Breathing apparatus
  • IS 1681: Woolen blankets
  • IS 274 (Parts 1 & 2): Shovels
  • IS 927: Fire hooks
  • IS 4770: Rubber gloves for electrical purposes
  • IS 5991: Rakes
  • IS 703, 704, 841: Axes, crowbars, hammers

Notes on Compliance

  • Equipment quantities and types can be adjusted based on local needs.
  • Rounding of numerical values per IS 2:1960.
  • Equipment must meet relevant IS specifications for quality and safety.

flowchart TD
    A[Fire Appliance] --> B[Breathing Apparatus (6 sets)]
    A --> C[Protective Suits (4 Nos.)]
    A --> D[Hydraulic Tools]
    A --> E[Rescue & Safety Equipment
2References

IS 949 - References Summary

IS 949 references several Indian Standards (IS) and equipment specifications essential for compliance and design. Key points:

Important Referenced IS Codes (Annex B)

IS No.Title
IS 5:2007Colours for ready mixed paints and enamels
IS 704:1984Specification for crow-bars and claw-bars
IS 273:1990Picks and beaters - Specification
IS 841:1983Specification for steel hammers
IS 274 (Pt 1 & 2)Specification for shovels (general & heat-treated)
IS 927:1981Specification for fire hooks
IS 1681:1998Textiles - Hospital blankets, woolen, dyed
IS 4770:1991Rubber gloves - Electrical purposes
IS 10245 (Pt 2)Respiratory protective devices - Breathing apparatus

Equipment Schedule (Annex A)

  • Breathing apparatus: 6 sets (IS 10245 Pt 2)
  • Protective suits: 4 Nos.
  • Blankets: 6 woolen (IS 1681)
  • Oxygen cylinder: 1 spare (5 litres)
  • Chain lifting equipment: Various capacities (2t, 5t)
  • Goggles, gloves, tarpaulins, and other rescue tools

Rounding Off (IS 2:1960)

  • Numerical values must be rounded to the same significant figures as specified.

Summary Diagram: Reference Flow

graph LR
A[IS 949 Standard] --> B[Annex B: Indian Standards]
B --> C[IS 5:2007, IS 704:1984, IS 273:1990, ...]
A --> D[Annex A: Equipment List]
D --> E[Breathing Apparatus (IS 10245)]
D --> F[Protective Suits, Blankets (IS 1681)]
D --> G[Chains, Gloves, Goggles]

Use the latest editions of referenced IS codes for compliance and safety.

3General Requirements

IS 949: General Requirements Summary

Key Specifications (Clause 5.6.7.1 - Superstructure details):

Member TypeSize (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members (even side)45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20

Rounding Off (IS 2:1960):

  • Final test/analysis values must be rounded to the same number of significant digits as the specified values.
  • Follow IS 2 rules strictly for consistency.

Additional Notes:

  • Refer to Annex B for related IS standards on tools, materials, and safety equipment.
  • Ensure compliance with referenced IS codes for materials and accessories.
flowchart TD
    A[General Requirements] --> B[Superstructure Dimensions]
    B --> C[Under frame cross members: 100x50x5 mm]
    B --> D[Floor longitudinal members: 50x50x6 mm]
    B --> E[Vertical members: 45x45x20 mm]
    B --> F[Skirt, Waist, Top deck: 45x45x20 mm]
    A --> G[Rounding off per IS 2:1960]

This concise summary aids in quick verification of structural member sizes and rounding rules per IS 949.

4Materials

IS 949 - Materials: Key Specifications & Dimensions (Clause 5.6.7.1)

Structural ElementSize (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members (even side)45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20
  • Dimensions are width × height × thickness in mm.
  • These sizes ensure adequate strength and rigidity for superstructure components.

Additional Notes:

  • Materials should comply with relevant IS standards for steel quality.
  • Rounding off of values must follow IS 2:1960.
  • Refer to IS 10245 (Part 2) for breathing apparatus materials and IS 1681 for woolen blankets.

Quick Reference Table for Structural Members

Member TypeWidth (mm)Height (mm)Thickness (mm)
Under frame cross members100505
Floor longitudinal members50506
Vertical members454520
Skirt/Waist/Top deck454520

If you need formulas for structural design (e.g., bending, shear), please specify.

5Design and Construction

IS 949: Design and Construction Key Specifications

1. Structural Member Dimensions (Clause 5.6.7.1)

Member TypeSize (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members (even side)45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20

2. Chassis Design (Clause 5.1)

ParameterSmall TenderLarge Tender
Gross Vehicle Weight≥ 16,000 kg≥ 25,000 kg
Wheel Base≤ 4.50 m≤ 5.00 m
Turning Circle≤ 20 m≤ 20 m
Road Clearance≥ 0.23 m≥ 0.23 m
Overall Width≤ 2.50 m≤ 2.50 m
Height≤ 3.60 m (from ground)≤ 3.60 m (from ground)

3. Material Specification (Clause 4.5)

  • No ferrous metal for nickel or chromium plated fittings.
  • Plating must be of extra heavy quality.

Additional Notes:

  • Use steel sections as per sizes above for superstructure.
  • Design must consider loadings per vehicle weight and operational conditions.
  • Refer to IS 949 for detailed welding, jointing, and corrosion protection guidelines.

graph TD
A[Chassis] --> B[Under Frame Cross Members: 100x50x5 mm]
A --> C[Floor Longitudinal Members: 50x50x6 mm]
A --> D[Vertical Members: 45x45x20 mm]
A --> E[Skirt, Waist & Top Deck Members: 45x45x20 mm]

This summarizes the key design and construction parameters per IS 949.

5.3Fuel System

IS 949 - Fuel System Key Points

Fuel Tank Capacity (Clause 5.3.1)

  • Small tender: Minimum 140 litres
  • Large tender: Minimum 250 litres
  • A fuel tank contents gauge must be fitted on the instrument panel.

Fuel Fitting Orifice (Clause 5.3.2)

  • Must be ample size for easy refueling.
  • Positioned for easy accessibility.
  • Fuel cap must be clearly marked "Fuel".
  • For petrol engines, an anti-flash device is mandatory on the cap to prevent flashback.

Equipment Related to Fuel System (Annex A & Clause 3.1)

  • Includes oxygen cylinders, gauges for cutting plants, and protective gear listed for operational safety but not directly part of the fuel system.

Summary Table: Fuel Tank Capacity

Tender TypeMinimum Fuel Tank Capacity (litres)
Small140
Large250

Diagram: Fuel System Essentials

flowchart LR
    FuelTank[Fuel Tank (140/250 L)]
    Orifice[Fuel Fitting Orifice]
    Cap[Fuel Cap with Anti-flash Device]
    Gauge[Fuel Contents Gauge]
    DriverPanel[Instrument Panel]

    FuelTank --> Orifice --> Cap
    FuelTank --> Gauge --> DriverPanel

Note: Ensure fuel system components comply with accessibility, safety (anti-flash for petrol), and capacity requirements per IS 949.

5.4Electrical System

IS 949: Electrical System Key Points (Clause 5.4 & 5.4.1)

  • Electrical System Voltage: Vehicle electrical system must be either 12 V or 24 V DC.
  • Alternator/Generator: A heavy-duty alternator/generator is mandatory, fitted to the engine.
  • Control Unit: Alternator/generator must include the necessary control unit for regulation and protection.

Typical Specifications for Vehicle Electrical System (per IS 949):

ParameterSpecification
Voltage12 V or 24 V DC
Alternator TypeHeavy duty, engine-driven
Control UnitVoltage regulator & protective

Additional Notes:

  • The alternator must be capable of supplying all electrical loads reliably.
  • Control unit ensures voltage stability and prevents overcharging.
  • For working voltages beyond vehicle systems (up to 33 kV), refer to IS 3.3 and related standards for cables and apparatus.

Simplified Electrical System Flow:

flowchart LR
    Engine --> Alternator[Heavy Duty Alternator/Generator]
    Alternator --> ControlUnit[Control Unit (Voltage Regulator)]
    ControlUnit --> VehicleElectricalSystem[12V or 24V DC System]

This ensures a stable DC supply for vehicle operations as per IS 949 requirements.

5.5Alternator and Generator Controls

IS 949: Alternator and Generator Controls - Key Specifications & Formulas

Controls (Clause 5.5.5)

  • Sockets & Switches:
    • 3-phase: 3 sockets with switches
    • Single-phase: 4 sockets @ 20 A MCB + 4 sockets @ 10 A MCB
  • Meters:
    • RPM Meter (digital) - 1 No.
    • kW Meter - 1 No.
    • Ampere Meter (per phase) - 3 Nos.
    • Frequency Meter - 1 No.
  • Protection & Control:
    • 32 A TPN MCB - 1 No.
    • Hand throttle control
    • Engine cooling water temperature gauge (if water cooled)

Alternator Specifications (Clauses 5.5, 5.5.2, 5.5.3)

  • Rating: Minimum 25 kVA, 0.8 power factor (4 kW), 220 V, 3-phase, 50 Hz
  • Type: Screen protected, self-regulating, self-excited, Class 'E' insulation
  • Exciter: Direct coupled flange mounted exciter with automatic voltage regulation maintaining voltage within ±5% over all loads at power factors between 0.8 and 1.

Voltage Regulation Formula (approximate):

[ V = V_{no-load} - I \times Z_{eq} ] Where:

  • (V) = terminal voltage at load
  • (V_{no-load}) = voltage at no load
  • (I) = load current
  • (Z_{eq}) = equivalent impedance of alternator

Typical Metering Connections (simplified):

graph LR
    A[Alternator Output] --> B[3-Phase Ampere Meters (3 Nos.)]
    A --> C[kW Meter]
    A --> D[Frequency Meter]
    A --> E[RPM Meter]
    A --> F[Sockets & Switches]

Summary: IS 949 mandates specific control components near the generator for safety, monitoring, and regulation, with an alternator designed for stable voltage output and rated minimum 25 kVA at 220 V, 50 Hz.

5.6Body Work

IS 949 - Body Work Key Specifications and Dimensions

1. Structural Member Sizes (Clause 5.6.7.1)

Member TypeSize (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members (even side)45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20

2. Design Requirements (Clauses 5.9.7, 5.1, 5.13)

  • Enclosure: Bodywork should enclose the appliance fully without restricting access, maintaining clean lines.
  • Chassis Dimensions:
ParameterSmall TenderLarge Tender
Gross Vehicle Weight≥ 16,000 kg≥ 25,000 kg
Wheel Base≤ 4.50 m≤ 5.00 m
Turning Circle≤ 20 m≤ 20 m
Road Clearance≥ 0.23 m≥ 0.23 m
Overall Width≤ 2.50 m≤ 2.50 m
Height≤ 3.60 m (from ground)≤ 3.60 m (from ground)
  • Stability: Overturning angle ≥ 27.5° under fully loaded conditions (excluding crew).

Summary

  • Use steel sections as per sizes above for body framework.
  • Ensure design enclosure balances protection and accessibility.
  • Maintain chassis and body dimensions within specified limits.
  • Verify stability with a minimum overturning angle of 27.5°.
graph TD
  A[Body Work] --> B[Under Frame Cross Members: 100x50x5]
  A --> C[Floor Longitudinal Members: 50x50x6]
  A --> D[Vertical Members: 45x45x20]
  A --> E[Skirt, Waist, Top Deck
5.9Miscellaneous Features

IS 949 - Miscellaneous Features: Key Specifications & Equipment Schedule

1. Equipment Schedule (Clause 3.1, Annex A)

  • Breathing apparatus (positive pressure): 6 sets (per IS 10245 Part 2)
  • Protective suits (Proximity/Chemical): 4 Nos.
  • Ambu bags: 1 set
  • MFR Kit: 2 sets
  • Blankets (Woolen, IS 1681): 6 Nos.
  • Oxygen cylinder (spare 5 litre): 1 No.
  • Leather gloves: 2 pairs
  • Goggles/Dark glasses: 4 pairs
  • Chains & lifting equipment:
    • Lifting chain 5 t: 6 m
    • Chain-sling double leg: 1
    • Chain tackle 2 t: 1 set
  • Tarpaulin: 2 Nos. (3.5 m × 3.5 m)
  • Pulling/lifting machine: 2 sets (lifting 3 t or pulling 5 t)

2. Additional Tools & Equipment (Clause 3.5, Annex A)

  • Hydraulic jacks: Various capacities (min 15 t to 50 t)
  • Hydraulic cutters, spreaders, pumps
  • Hand tools: Axes, crow bars, shovels, hammers (per IS 703, IS 704, IS 841)
  • Safety equipment: Rubber gloves (IS 4770), high safety boots, goggles
  • Electrical tools: Portable drills, circular saws, chain saws
  • Rescue & safety: Jumping cushions, evacuation systems, inflatable boats, thermal imaging cameras

3. Referenced IS Standards for Equipment

IS No.Title
IS 10245 (Part 2)Breathing apparatus
IS 1681Woolen blankets
IS 927Fire hooks
IS 274 (Part 1 & 2)Shovels
IS 273Picks and beaters
IS 703Axes
IS 704Crow bars
IS 841Steel hammers
IS 4770Rubber gloves (
5.10Lockers and Equipment Storage

IS 949 - Lockers and Equipment Storage: Key Specifications & Tables

1. Locker Design (Clause 5.10.1, 5.10.5, 5.10.6)

  • Lockers must store all equipment from Annex A, with roll-in/roll-out drawers in a tapered opening for quick access.
  • Each equipment has a designated labeled location for easy identification.
  • Lockers covered with push-pull type aluminium roller shutters:
    • Made of anodized extruded aluminium sections.
    • Shutters roll inwards under the roof for unobstructed access.
  • Internal lighting inside lockers:
    • Automatically switches ON/OFF with shutter operation.
    • Includes a master isolating switch.

2. Stretcher-Ladders (Clause 5.12.1)

ParameterSpecification
Overall length≥ 2.0 m
Overall width≥ 600 mm
Centre of rungs≈ 210 mm spacing
MaterialAluminium alloy
MountingSeparate, quick removable

Summary Diagram of Locker Components

graph LR
A[Locker Frame] --> B[Roll-in/Roll-out Drawers]
B --> C[Designated Equipment Slots with Labels]
A --> D[Aluminium Roller Shutter]
D --> E[Rolls Inwards Under Roof]
A --> F[Internal Lighting]
F --> G[Auto ON/OFF with Shutter]
F --> H[Master Isolating Switch]

This ensures efficient, rapid access to firefighting equipment during emergencies per IS 949 standards.

6Workmanship and Finish

IS 949: Workmanship and Finish - Key Points

1. Stability (Clause 5.13)

  • Appliance must resist overturning up to a tilt angle of 27.5° under fully equipped and loaded conditions (excluding crew).

2. Workmanship (Clause 6.1)

  • Mechanical parts must be manufactured for easy replacement and proper fit.
  • High-quality finish ensuring durability and serviceability.

3. Structural Member Specifications (Clause 5.6.7.1 - Table)

Member TypeDimensions (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members on even side45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20

4. Finishing (Clause 4.5)

  • No ferrous metals for nickel/chromium plated fittings.
  • Plating must be extra heavy quality for corrosion resistance.

Summary Diagram of Member Placement

graph TB
  A[Under Frame Cross Members<br>100x50x5] --> B[Floor Longitudinal Members<br>50x50x6]
  B --> C[Vertical Members on Even Side<br>45x45x20]
  C --> D[Skirt Member<br>45x45x20]
  D --> E[Waist Member<br>45x45x20]
  E --> F[Top Deck Longitudinal<br>45x45x20]

This ensures structural integrity, ease of maintenance, and aesthetic finish per IS 949 standards.

7Instruction Book and Accessories

IS 949: Instruction Book and Accessories - Key Points

Instruction Book (Clause 7.1)

  • Must provide operating and maintenance procedures.
  • Include an itemized, illustrated spare parts list referencing all wearing parts.
  • Essential for user guidance and equipment upkeep.

Painting & Phosphating (Clause 6.6)

  • Chassis painting/phosphating must withstand tropical climatic conditions.

Accessories & Equipment Schedule (Clause 3.1 & Annex A)

  • Equipment list varies by local conditions; chassis size may adjust accordingly.
  • Typical accessories include:
Item DescriptionQuantity
Breathing apparatus (IS 10245 Part 2)6 sets
Protective suits (Proximity/chemical)4 Nos.
Woolen blankets (IS 1681)6 Nos.
Oxygen cylinder (5 litre)1 No.
Gauges for oxy-acetylene cutting plant2 Nos.
Leather gloves2 pairs
Goggles/dark glasses4 pairs
Chain lifting 5t (with shackles)6 m
Chain sling, double leg1 No.
Chain tackle 2t (pulley block)1 set
Tarpaulin (3.5m × 3.5m)2 Nos.
Pulling/lifting machine (3t lift or 5t pull)2 sets

Referenced IS Standards (Annex B)

  • Paints: IS 5:2007
  • Protective gloves: IS 4770:1991
  • Breathing apparatus: IS 10245 (Part 2)
  • Woolen blankets: IS 1681:1998
  • Others for tools and accessories (axes, shovels, hammers, etc.)

Summary Diagram: Instruction Book & Accessories Flow

flowchart TD
    A[Instruction Book] --> B[Operating Procedures]
    A --> C[Maintenance Procedures]
    A --> D[Spare Parts List]
    E[Accessories] --> F[Breathing Apparatus]
    E --> G[Protective Suits]
    E --> H[Gloves & Goggles]
    E --> I[Chains & Lifting Equipment]
    E --> J[Miscellaneous Tools]
Annex ACommittee Composition

IS 949 - Committee Composition & Key Specifications

  • Committee Composition:
    The detailed composition of the Fire Fighting Sectional Committee (CED 22) responsible for IS 949 is provided in Annex C of the standard. This includes experts from various stakeholder groups ensuring comprehensive standard formulation.

  • Key Structural Specifications (Clause 5.6.7.1 - Body Work):

Member TypeDimension (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members (even side)45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20
  • Note: Dimensions are width × depth × thickness (mm).

This ensures uniformity in fire fighting vehicle body construction per IS 949 requirements.

graph TD
    A[Committee CED 22] --> B[Experts from Industry]
    A --> C[Government Representatives]
    A --> D[Academia]
    A --> E[Testing Agencies]
    F[Annex C] --> A

For detailed committee member names and roles, refer to Annex C of IS 949.

Annex BReferenced Standards

IS 949 - Referenced Standards Summary

Annex B lists Indian Standards referenced in IS 949, which form integral provisions. Key IS codes include:

IS No.Title
5 : 2007Colours for ready mixed paints and enamels
273 : 1990Picks and beaters - Specification
274 (Part 1 & 2) : 1981Specification for shovels (General & Heat-treated)
704 : 1984Specification for crow-bars and claw-bars
841 : 1983Specification for steel hammers
927 : 1981Specification for fire hooks
4770 : 1991Rubber gloves - Electrical purposes
5991 : 1971Specification for ballast rakes
10245Respiratory protective devices
9968 (Part 1 & 2)Elastomer insulated cables for various voltages

Important Notes:

  • Rounding off: Follow IS 2:1960 for numerical rounding.
  • Refer to the latest editions of these standards for compliance.
  • These referenced standards cover tools, protective equipment, cables, and fire-fighting accessories.

Visual: Reference Flow

graph LR
A[IS 949] --> B(Annex B: Referenced IS Codes)
B --> C[Tools: Picks, Shovels, Hammers]
B --> D[Protective Equipment: Gloves, Respiratory Devices]
B --> E[Electrical: Cables, Insulation]
B --> F[Fire Fighting Accessories]

For detailed specifications, refer directly to the respective IS codes listed in Annex B.

Popular Questions About IS 949

?What are the minimum fuel tank capacities specified for emergency tenders?

According to IS 949 (2012), Clause 5.3.1, the minimum fuel tank capacities for emergency tenders are:

  • Small Tender: Minimum 140 litres
  • Large Tender: Minimum 250 litres

Additional requirement:

  • A fuel tank contents gauge must be fitted on the instrument panel in the driving compartment for monitoring fuel levels.

This ensures adequate operational range during emergency response without frequent refueling.


Summary Table

Tender TypeMinimum Fuel Tank Capacity
Small Tender140 litres
Large Tender250 litres

If you need further details on chassis specs or dimensions, refer to Clause 5.1 of IS 949.

?What materials and construction methods are mandated for the vehicle superstructure?

According to IS 949, the vehicle superstructure must follow these material and construction requirements:

  • Material:

    • Use 2 mm mild steel pressed 'TOP HAT' sections (45 mm × 45 mm × 20 mm) for the superstructure frame.
    • Strengthen members, especially where locker door frames fit, with 2 mm mild steel plate brackets and gussets, securely welded.
    • Timber is prohibited in body construction (Clause 4.2).
  • Section Sizes (Clause 5.6.7.1):

ComponentSection Size (mm)
Under frame cross members100 × 50 × 5
Floor longitudinal members50 × 50 × 6
Vertical members45 × 45 × 20
Skirt member45 × 45 × 20
Waist member45 × 45 × 20
Top deck longitudinal45 × 45 × 20
  • Construction:
    • Cab and lockers should be composite construction with adequate rigidity and reinforcement, designed to be as light as possible.

This ensures a strong, lightweight, and durable superstructure without timber components.

?How does the standard address electrical system safety and battery charging?

According to IS 949 Clause 5.4.2 on Electrical System safety and battery charging:

  • A trickle charger must be installed inside the cab.
  • It should have a socket for connection to 230 V AC supply.
  • A red pilot lamp must indicate when the battery is charging from an external source.

This ensures continuous battery maintenance without overcharging, enhancing safety and reliability.

Key points:

  • Trickle charger: Provides low current to keep battery charged.
  • 230 V AC socket: Standard mains connection.
  • Red pilot lamp: Visual charging status indicator.

This setup prevents battery damage, electrical hazards, and ensures operational readiness.

Loading diagram...

This simple electrical safety provision aligns with best practices for vehicle battery management.

?What stability requirements must the tender meet under fully loaded conditions?

According to IS 949 Clause 5.13, the stability requirement for a fully equipped and loaded tender (excluding crew) is:

  • The appliance must not overturn when the surface it stands on is tilted up to 27.5° from the horizontal in either direction.

This means:

  • The overturning angle ≥ 27.5° under fully loaded conditions.
  • Stability is assessed by tilting the vehicle sideways and ensuring it does not tip before this angle.

Key points:

  • Applies to fully equipped and loaded condition (crew excluded).
  • Ensures safe operation on inclined surfaces.
  • Critical for emergency tenders to maintain stability during deployment.

Visual summary:

Loading diagram...

This stability criterion ensures safe operation on slopes and uneven terrain during emergency response.

?What types of lockers and access mechanisms are required for equipment storage?

According to IS 949, equipment storage lockers must have the following features:

  • Locker Type: Roll-in, roll-out drawers with tapered opening for easy, immediate access (Clause 5.10.1).
  • Access Mechanism: Push-pull type aluminium roller shutters made from anodized extruded aluminium sections, rolling inward under the roof for unobstructed access (Clause 5.10.5).
  • Lighting: Internal lighting automatically controlled by shutter opening/closing, plus a master isolating switch (Clause 5.10.6).
  • Organization: Each equipment piece must have a designated, labeled location for quick identification and retrieval (Clause 5.10.1).
  • Additional Lockers: Below crew seats, two lockers—one for batteries and one for accessories—must be provided (Clause 5.6.6.3).

This design ensures fast, smooth rescue operations and systematic equipment storage.

Loading diagram...

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 949. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required