IS 8758 Part B (1993) provides comprehensive recommendations for fire precautionary measures in the construction, maintenance, and use of temporary structures and pandals used for public and private outdoor assemblies in India. It covers material selection, structural design, electrical safety, fire fighting arrangements, and evacuation protocols to ensure minimum fire resistance and safe occupancy. This standard is essential for engineers, architects, and safety officials involved in planning and managing temporary event structures to mitigate fire risks effectively.
Overview
IS 8758 Part B (1993) provides comprehensive recommendations for fire precautionary measures in the construction, maintenance, and use of temporary structures and pandals used for public and private outdoor assemblies in India. It covers material selection, structural design, electrical safety, fire fighting arrangements, and evacuation protocols to ensure minimum fire resistance and safe occupancy. This standard is essential for engineers, architects, and safety officials involved in planning and managing temporary event structures to mitigate fire risks effectively.
Audience
Contents
Structure
IS 8758 Part B – Scope Summary
Scope (Clause 3.1):
Covers materials, design, construction, and fabrication of fire-resistant structures/devices.
Key Specification:
Fire resistance time ≥ max(10 minutes, total evacuation time)
| Parameter | Requirement |
|---|---|
| Fire resistance duration | Minimum 10 minutes or evacuation time |
| Materials & design | Must comply with fire resistance criteria |
flowchart TD
A[Start: Design Fire-Resistant Structure] --> B{Determine Evacuation Time}
B -->|Evacuation Time < 10 mins| C[Set Fire Resistance = 10 mins]
B -->|Evacuation Time ≥ 10 mins| D[Set Fire Resistance = Evacuation Time]
C --> E[Select Materials & Design Accordingly]
D --> E
E --> F[Construct & Fabricate as per IS 8758]
F --> G[Achieve Fire Resistance Compliance]
For detailed design and material specifications, refer to full IS 8758 Part B text and related fire safety codes.
Referenced Standards are essential adjuncts to IS 8758 Part B, ensuring comprehensive fire safety and structural integrity.
| Clause | Description | Key Requirement |
|---|---|---|
| 2.1 | Referenced Indian Standards | IS 1646:1982 (Fire safety in electrical installations) |
| 3.1 | Fire Resistance Requirements | Min. 10 minutes or evacuation time |
For detailed fire safety design, refer to IS 1646 for electrical installations and related fire precautionary measures.
flowchart LR
A[IS 8758 Part B] --> B[Fire Resistance: Min 10 min]
A --> C[Referenced Standards]
C --> D[IS 1646:1982 - Electrical Fire Safety]
B --> E[Material & Design Compliance]
D --> E
Contact BIS or consult the full standards for detailed tables and formulas on fire resistance ratings.
IS 8758 Part B: General Requirements Summary
| Location/Type | Minimum Fire Resistance (minutes) |
|---|---|
| Exit routes | 10 |
| Assembly areas | 15 |
| Electrical rooms | 30 |
(Note: Exact values to be confirmed from full Table 4 in Clause 3.2)
flowchart LR
A[Design & Materials] --> B{Fire Resistance Time}
B -->|≥ 10 min| C[Meets IS 8758 Part B]
B -->|< 10 min| D[Revise Design]
C --> E[Safe for Evacuation]
Use IS 1646 and IS 8758 together for comprehensive fire safety design in temporary structures.
IS 8758 Part B: Location and Safety Distances - Key Points
| Hazard/Feature | Minimum Safety Distance (m) |
|---|---|
| Furnace | 15 |
| Railway line | 15 |
| Electrical sub-station | 15 |
| Chimney | 15 |
| High tension wires | 15 |
| Clearing zone around structure | 4.5 outside perimeter |
flowchart LR
A[Temporary Structure] -->|15 m| B[Furnace/Railway/Electrical Sub-station/Chimney/HT Wire]
A -->|4.5 m clearance| C[Combustible Material Free Zone]
A --> D[Access & Exits per Capacity]
Ensure compliance with these distances to maintain safety and regulatory adherence.
IS 8758 Part B: Means of Access - Key Points
| Parameter | Minimum Dimension/Requirement |
|---|---|
| Safety distance from hazards | 15 m |
| Gate clear opening width | 5 m |
| Archway height | 5 m |
| Capacity control | As per Clause 6.1 (area-based) |
| Escape routes | Unobstructed, visible equipment |
flowchart LR
A[Temporary Structure] --> B[Maintain 15m Safety Distance]
A --> C[Gate Opening ≥ 5m]
A --> D[Archway Height ≥ 5m]
A --> E[Capacity ≤ Clause 6.1]
A --> F[Unobstructed Exits & Visible Fire Equipment]
This ensures safe, easy access and egress for temporary structures per IS 8758 Part B.
IS 8758 Part B: Capacity and Occupancy Key Points
| Parameter | Value/Formula |
|---|---|
| Standing space per person | 0.50 m² |
| Bench seat length per person | 450 mm (0.45 m) |
| Minimum exit width | 1.5 m |
| Capacity formula | Fixed seats + (Floor area for standing ÷ 0.5) |
flowchart TD
A[Floor Area] --> B{Designated for?}
B -->|Fixed seats| C[Count seats]
B -->|Standing/movable seats| D[Area ÷ 0.5 m² per person]
C --> E[Sum seats]
D --> E
E --> F[Total Capacity]
F --> G[Check Occupancy ≤ Capacity]
G --> H[Provide exits ≥ 1.5 m width]
This ensures safe, code-compliant assembly occupancy and egress design.
IS 8758 Part B: Enclosure and Exits Key Points
| Parameter | Requirement |
|---|---|
| Number of exits | Minimum 2 |
| Width of each exit | ≥ 2.5 m (preferred), ≥ 1.5 m minimum |
| Location of exits | At extremities, separately located |
graph LR
A[Temporary Structure] --> B(Exit 1: ≥ 2.5 m width)
A --> C(Exit 2: ≥ 2.5 m width)
B --- C
Note: Ensure exits are unrestricted, well-marked, and located at opposite ends for safe evacuation.
IS 8758 Part B — Electrical Arrangements Key Points
Clause 8.1:
Clause 8.2:
| Parameter | Specification |
|---|---|
| Minimum clearance (seating) | 55 cm (general), 30 cm (self-folding seats) |
| Wiring type | PVC sheathed or vulcanized rubber cables |
| Joints | Porcelain insulated connectors only |
| Installation standard | IS 1646:1982 |
flowchart TD
A[Temporary Lighting Installation] --> B[Licensed Electrical Engineer]
B --> C[Load per Circuit & Insulation Test]
C --> D[Compliance with IS 1646:1982]
D --> E[Use PVC Sheathed or Vulcanized Rubber Cables]
E --> F[Joints with Porcelain Insulated Connectors]
F --> G[No Twisted & Taped Joints Allowed]
This ensures safe, fire-resistant electrical arrangements in temporary pandal structures.
Fire Protection Measures as per IS 8758 Part B
| Item | Requirement |
|---|---|
| Fire Buckets | 2 per 50 m² floor area |
| Water Extinguishers | 1 (9 L) per 100 m² floor area |
| CO₂/BCF Extinguishers | 1 per electrical installation area |
| Water Supply | 0.75 L/m² floor area |
| Fire Resistance of Materials | ≥ 10 minutes or evacuation time |
| Halogen Lamps | Not allowed inside structures |
flowchart LR
A[Temporary Structure] --> B[Fire Buckets (2 per 50 m²)]
A --> C[Water Extinguishers (1 per 100 m²)]
A --> D[Water Supply (0.75 L/m²)]
A --> E[Electrical Fire Extinguishers (CO₂/BCF)]
A --> F[Materials Fire Resistance ≥ 10 mins]
A --> G[No Halogen Lamps Allowed]
This ensures compliance with
IS 8758 Part B – Fire Fighting Arrangements: Key Points
| Item | Quantity per Floor Area |
|---|---|
| Fire buckets | 2 buckets per 50 m² |
| Water-type extinguisher (9L) | 1 extinguisher per 100 m² |
| CO₂ or BCF extinguisher | 1 for each switchgear, main meter, and stage area (for electrical protection) |
| Aspect | Requirement |
|---|---|
| Water supply | 0.75 l/m² |
| Fire buckets | 2 per 50 m² |
| Water extinguisher | 9L, 1 per 100 m² |
| CO₂/BCF extinguisher | 1 per switchgear/main meter/stage |
| Kitchen segregation | Separate, GI sheets preferred |
| Standby fire service | As per local authority |
flowchart LR
A[Temporary Structure] --> B[Water Supply: 0.75 l/m²]
B --> C[Buckets: 2 per 50 m²]
B --> D[Water Extinguisher: 9L per 100 m²]
A --> E[Electrical Installations]
E --> F[CO₂/BCF Extinguisher per switchgear/meter/stage]
A --> G[Kitchen Area]
G --> H[Segregated, GI Sheets]
A
IS 8758 Part B: Maintenance and Inspection Key Points
| Activity | Frequency | Action Required |
|---|---|---|
| Visual Inspection | Daily/Weekly | Check for visible defects/damage |
| Functional Testing of Devices | Monthly | Ensure all safety devices operate |
| Structural Integrity Check | Quarterly/After Event | Check for corrosion, cracks, etc. |
| Fire Resistance Verification | Annually | Confirm compliance with fire rating |
[ t_{fire} \geq \max(10 \text{ minutes}, t_{evacuation}) ]
Where:
flowchart TD
A[Temporary Structure] --> B[Periodic Inspection]
B --> C{Defects Found?}
C -- Yes --> D[Report to Authority]
C -- No --> E[Continue Operation]
D --> F[Remedial Action]
F --> E
E --> G[Maintain Fire Resistance ≥ 10 min]
Note: Always refer to the latest IS 8758 Part B for detailed inspection checklists and maintenance procedures.
From Annex A (Foreword):
Key Points:
Capacity Calculation (Clause 6.1): [ \text{Capacity} = \text{Number of fixed seats} + \frac{\text{Standing area (m}^2)}{0.5} ]
Admission Limit (Clause 6.2):
Seating Clearance (Clause 7.9):
flowchart TD
A[Committee Composition] --> B[Government Agencies]
A --> C[Industry Experts]
A --> D[Research Institutes]
A --> E[Fire Safety Authorities]
B --> F[Ministry of Defence, BIS, CEA]
C --> G[Tata Consulting Engineers, Hindustan Construction]
D --> H[CSIR, Metallurgical Engg. Consultants]
E --> I[Institution of Fire Engineers, Fire Advisers]
Summary:
IS 8758 Part b’s committee is a multidisciplinary panel ensuring comprehensive fire safety standards, with clear capacity and seating guidelines for outdoor assembly structures.
Frequently Asked
According to IS 8758 Part b for temporary structures:
| Requirement | Detail |
|---|---|
| Fire resistance duration | Minimum 10 minutes or total evacuation time |
| Applicable materials | Straw, hay, grass, canvas, etc. |
| Fabric treatment | Fire retardant solution or Class I flame spread |
This ensures safe evacuation and reduces fire hazards in temporary public assembly structures.
Loading diagram...
According to IS 8758 Part B, decorative fabrics used in construction must be treated to reduce fire hazards as follows:
Pre-treatment: All fabrics and decorative cloths must be dipped in a fire retardant solution or treated with other suitable materials to achieve a Class I flame spread factor (Clause 3.6).
Fire retardant solution composition (Clause 3.2):
| Material | Parts by Mass |
|---|---|
| Ammonium sulphate | 4 |
| Ammonium carbonate | 2 |
| Borax | 1 |
| Boric acid | 1 |
| Alum | 2 |
| Water | 35 |
Additional precautions (Clause 8.5): Avoid using halogen lamps inside temporary structures to minimize ignition risk.
This treatment significantly lowers fabric combustibility, ensuring safer temporary structures and pandals.
Minimum Requirements for Exits and Gangways in Pandals (IS 8758 Part B):
Exits:
Gangways:
Ceiling height: Minimum 3 m from ground level (Clause 3.4).
Safety clearance: Clear combustible materials within 4.5 m outside the structure (Clause 9.1).
Loading diagram...
This ensures safe, unobstructed evacuation and orderly seating in temporary pandal structures.
According to IS 8758 Part B, the minimum fire fighting equipment requirements for temporary structures are:
Fire Buckets:
Water-type Fire Extinguishers:
CO₂ or BCF Extinguishers:
Location:
Additional Measures:
| Equipment Type | Quantity | Notes |
|---|---|---|
| Fire Buckets | 2 per 50 m² | Filled with water |
| Water Extinguishers | 1 per 100 m² (9 liters) | |
| CO₂/BCF Extinguishers | 1 per electric installation (switchgear, etc.) | For electrical fires |
| Water Supply | 0.75 liters/m² total | Half inside, half outside |
Loading diagram...
Ensure compliance with local fire authority for additional requirements.
Safe Arrangement of Electrical Installations in Temporary Structures (IS 8758 Part B)
| Parameter | Requirement |
|---|---|
| Installer | Licensed electrical engineer |
| Load per circuit | As per IS 1646 |
| Insulation resistance | Minimum as per IS 1646 standards |
| Maintenance | Continuous, safe, and sanitary |
Loading diagram...
Summary: Follow IS 1646 for wiring and load, ensure licensed installation, test insulation, and maintain devices for fire-safe electrical setups in temporary structures.