IS 771 Part 61979AI Search Enabled✦ AI Generated

Glazed Fire-clay Sanitary Appliances, Part VI: Specific Requirements of Bed Pan Sinks

IS 771 Part 6 (1979) specifies the detailed requirements for glazed fire-clay bed pan sinks used in sanitary installations. It covers the construction, dimensions, tolerances, and functional features such as flushing mechanisms and waste outlets to ensure hygienic and durable bed pan sinks. This standard is essential for manufacturers, designers, and engineers involved in healthcare facility sanitation and plumbing systems.

10Sections
85Clauses Indexed
AI Search Ready
1979Edition
Sanitary Appliances and Water FittingsCategory
Alternative search terms: IS 771 Part 6 PDF, IS 771 Part 6 pdf free download, IS 771 Part 6 free download pdf, IS771Part6 PDF, IS-771-Part-6 PDF, IS 771 Part 6 1979 PDF, IS 771 Part 6:1979 PDF, IS 771 Part 6-1979 PDF, IS 771 Part 6 (1979) PDF, IS 771 Part 6 1979 edition PDF, IS 771 Part 6 edition 1979 PDF

What This Standard Covers

IS 771 Part 6 (1979) specifies the detailed requirements for glazed fire-clay bed pan sinks used in sanitary installations. It covers the construction, dimensions, tolerances, and functional features such as flushing mechanisms and waste outlets to ensure hygienic and durable bed pan sinks. This standard is essential for manufacturers, designers, and engineers involved in healthcare facility sanitation and plumbing systems.

Who Uses This Standard

  • Sanitaryware Manufacturers
  • Civil Engineers
  • Public Health Engineers
  • Plumbing System Designers
  • Healthcare Facility Architects
  • Quality Control Inspectors
  • Sanitation Equipment Suppliers

Key Topics Covered

Material specifications for glazed fire-clay
Construction requirements of bed pan sinks
Standardized dimensions and tolerances
Two-piece construction design
Flushing rim and water inlet design
Waste outlet configurations
Surface finish and smoothness
Connection to outlet traps
Marking and certification requirements
Inspection and quality control procedures
Sampling and testing methods
Compliance with IS 771 Part I general requirements

Table of Contents

0Introduction

IS 771 Part 6 (1979) - Introduction: Key Specifications

1. Dimensions and Tolerances (Clause 2.4.2)

  • For dimensions < 50 mm: ± 2 mm tolerance
  • For dimensions ≥ 50 mm: ± 4% tolerance

2. Rounding Off (Clause 0.3)

  • Final test or calculation results shall be rounded as per IS: 2-1960.
  • Retain the same number of significant figures as specified values in the standard.

Summary Table: Permissible Tolerances

Dimension SizePermissible Tolerance
< 50 mm± 2 mm
≥ 50 mm± 4% of the dimension

Notes:

  • These tolerances ensure dimensional accuracy for structural elements.
  • Rounding rules maintain consistency in reporting test/analysis results.
flowchart TD
    A[Dimension Size] -->|< 50 mm| B[Tolerance ± 2 mm]
    A -->|≥ 50 mm| C[Tolerance ± 4%]
    D[Final Value] --> E[Rounded as per IS:2-1960]
    E --> F[Same significant figures as specified]

This concise framework governs dimensional accuracy and reporting precision in IS 771 Part 6.

1Scope

IS 771 Part 6 - Scope: Dimensions and Tolerances

  • Scope: Specifies permissible dimensions and tolerances for components in reinforced concrete construction.

Key Specifications from Clause 2.4:

Dimension RangePermissible Tolerance
Less than 50 mm± 2 mm
50 mm and above± 4% of the dimension

Rounding of Test/Analysis Results (Clause 0.3):

  • Round off values per IS 2-1960.
  • Retain significant figures equal to those in the specified standard value.

Summary:

  • Use ±2 mm tolerance for small dimensions (<50 mm).
  • Use ±4% tolerance for larger dimensions (≥50 mm).
  • Ensure consistent rounding in test results as per IS 2.
flowchart LR
    A[Dimension] --> B{< 50 mm?}
    B -- Yes --> C[Tolerance ± 2 mm]
    B -- No --> D[Tolerance ± 4%]

This ensures compliance with IS 771 Part 6 dimensional accuracy requirements.

2Requirements

IS 771 Part 6: Key Requirements Summary

  • Rounding Off (Clause 0.3):
    Final test or calculation values must be rounded per IS: 2-1960.

    • Retain the same number of significant figures as the specified value.
  • General Requirements (Clause 2.1):
    Material, manufacturing, testing, sampling, and inspection must comply with IS 771 Part 1 (1979).

  • Dimensions and Tolerances (Clause 2.4 & 2.4.2):
    Permissible tolerances on dimensions (see Fig. 1 in the code):

    Dimension SizeTolerance
    Less than 50 mm± 2 mm
    50 mm and over± 4% of dimension

Summary Table:

Dimension (mm)Tolerance
< 50± 2 mm
≥ 50± 4% (percentage)

This ensures dimensional accuracy and consistency for steel tubes as per IS 771 Part 6.

2.1General

IS 771 Part 6 – General: Key Specifications and Tolerances

1. General Requirements (Clause 2.1)

  • Material, manufacture, testing, sampling, and inspection must comply with IS 771 (Part 1)-1979.

2. Dimensions and Tolerances (Clause 2.4 & 2.4.2)

  • Permissible tolerances on dimensions (refer Fig. 1 in the code):
    • Dimensions < 50 mm: ± 2 mm
    • Dimensions ≥ 50 mm: ± 4% of the dimension

3. Rounding Off Results (Clause 0.3)

  • Final test or analysis values must be rounded per IS 2-1960.
  • Retain the same number of significant digits as the specified value.

Summary Table: Dimension Tolerances

Dimension SizeTolerance
Less than 50 mm± 2 mm
50 mm and above± 4% of size

This ensures uniformity in manufacturing and quality control for structural steel sections under IS 771 Part 6.

2.2Pattern and Size

IS 771 Part 6: Bed Pan Sink - Pattern and Size

  • Standard Size:
    Bed pan sink size is 600 mm × 450 mm (Clause 2.2, Fig. 1).

  • Tolerances on Dimensions (Clause 2.4.2):

    Dimension RangePermissible Tolerance
    < 50 mm± 2 mm
    ≥ 50 mm± 4% of the dimension
  • Material:
    Made of fire-clay as per Clause 1.1.

  • Additional Notes:

    • Dimensions are in millimeters.
    • Optional flange section shown in Fig. 1 (Section YY).
    • Numerical values rounded off as per IS rules.
flowchart LR
    A[Bed Pan Sink] --> B[Size: 600×450 mm]
    A --> C[Tolerances]
    C --> D{Dimension < 50 mm}
    C --> E{Dimension ≥ 50 mm}
    D --> F[± 2 mm]
    E --> G[± 4%]

This ensures dimensional accuracy and interchangeability in manufacturing bed pan sinks.

2.3Construction

IS 771 Part 6: Construction - Key Specifications

  • General Requirements (Clause 2.1):
    Materials, manufacturing, testing, sampling, and inspection must comply with IS 771 Part 1 (1979).

  • Dimensions and Tolerances (Clause 2.4 & 2.4.2):
    Permissible dimensional tolerances are:

    Dimension SizeTolerance
    Less than 50 mm± 2 mm
    50 mm and above± 4% of dimension
  • Construction (Clause 2.3):
    Construction methods should ensure compliance with the above tolerances and general quality requirements.


Summary Table of Tolerances

Dimension (mm)Permissible Tolerance
< 50± 2 mm
≥ 50± 4%

This ensures dimensional accuracy and quality control during construction as per IS 771 standards.

2.4Dimensions and Tolerances

IS 771 Part 6: Dimensions and Tolerances for Bed Pan Sink

1. Dimensions (Clause 2.4.1)

  • Bed pan sink dimensions must conform exactly to Fig. 1 of the code (refer to the standard for exact geometry).

2. Tolerances (Clause 2.4.2)

Dimension RangePermissible Tolerance
Less than 50 mm± 2 mm
50 mm and above± 4% of the dimension

3. Rounding Off (Clause 0.3)

  • Final measured or calculated values should be rounded as per IS 2-1960.
  • Retain the same number of significant digits as specified in the standard.

Summary Table for Quick Reference

Dimension (mm)Tolerance
< 50± 2 mm
≥ 50± 4% of length

This ensures manufacturing and quality control maintain proper fit and function of bed pan sinks as per IS 771 Part 6.

3Marking

IS 771 Part 6 – Marking: Key Points on Dimensions and Tolerances

  • Rounding Off (Clause 0.3):
    Final test or calculation values must be rounded per IS 2-1960.

    • Retain the same number of significant digits as specified in the standard.
  • Tolerances on Dimensions (Clause 2.4.2):
    For dimensions shown in Fig. 1:

    Dimension RangePermissible Tolerance
    Less than 50 mm± 2 mm
    50 mm and above± 4% of the dimension
  • Purpose:
    Ensures uniformity and accuracy in marking dimensions on structural elements per IS 771 Part 6 (1979).

flowchart LR
    A[Measured Dimension] --> B{Dimension < 50 mm?}
    B -- Yes --> C[Tolerance ± 2 mm]
    B -- No --> D[Tolerance ± 4% of dimension]
    C & D --> E[Apply rounding as per IS 2-1960]

Use these tolerances to verify compliance in marking dimensions on structural steel sections.

4Sampling and Inspection

IS 771 Part 6: Sampling and Inspection - Key Points

1. General Requirements (Clause 2.1)

  • Sampling and inspection must comply with IS 771 Part 1 (1979).
  • Material, manufacturing, and test methods follow the general guidelines in Part 1.

2. Dimensions and Tolerances (Clause 2.4)

  • Tolerances on dimensions (Fig. 1 reference):
Dimension RangePermissible Tolerance
Less than 50 mm± 2 mm
50 mm and above± 4% of the dimension

3. Rounding Off Results (Clause 0.3)

  • Final test values must be rounded as per IS 2:1960.
  • Retain the same number of significant digits as specified in the standard.

Summary Table for Tolerances:

Dimension (mm)Tolerance
< 50± 2 mm
≥ 50± 4% of dimension

This ensures inspection results are consistent and within acceptable limits for quality control.

flowchart TD
    A[Sampling & Inspection] --> B[Material & Manufacture per IS 771 Part 1]
    B --> C[Measure Dimensions]
    C --> D{Dimension < 50 mm?}
    D -- Yes --> E[Tolerance ± 2 mm]
    D -- No --> F[Tolerance ± 4%]
    E & F --> G[Check compliance]
    G --> H[Round off results as per IS 2:1960]
5Methods of Test

IS 771 Part 6 (1979) - Methods of Test: Key Points

  • General Reference: Testing methods conform to IS 771 Part I (1979), which outlines material, manufacture, sampling, inspection, and test procedures.

  • Rounding Off Results:
    Follow IS 2:1960 for rounding test results:

    • Round final values to the same number of significant figures as the specified standard value.
    • Ensures consistency and comparability of test data.
  • Typical Test Methods Covered (per IS 771 Part I):

    • Tensile strength
    • Bending tests
    • Hardness measurement
    • Chemical composition analysis
    • Dimensional checks
  • Sampling:
    Sampling must be representative as per IS 771 Part I guidelines to ensure test validity.


Summary Table: Rounding Off Test Results (IS 2:1960)

Specified ValueExample Test ResultRounded Result
12.0 mm12.034 mm12.0 mm
5.25 MPa5.246 MPa5.25 MPa
100.0 N99.87 N100.0 N

If you need detailed test procedures or specific formulas, refer to IS 771 Part I and IS 2:1960 for rounding rules.

Popular Questions About IS 771 Part 6

?What are the specified dimensions for bed pan sinks under IS 771 Part 6?

According to IS 771 Part 6 (1979) for bed pan sinks:

  • Size: The bed pan sink shall have overall dimensions of 600 mm × 450 mm (Clause 2.2).
  • Dimensions: These dimensions conform to the detailed layout shown in Fig. 1 of the standard (Clause 2.4.1).
  • Material: Made of glazed fire-clay (Clause 1.1).
  • Optional Feature: Flange section (marked as FLANGE in Fig. 1) may be included.

Summary:

ParameterDimension (mm)
Length600
Width450

All dimensions are in millimeters and follow the tolerances specified in the standard.

Loading diagram...

This ensures uniformity and interchangeability in healthcare settings.

?What construction features must a glazed fire-clay bed pan sink include?

According to IS 771 Part 6 (1979) for glazed fire-clay bed pan sinks, the construction features must include:

  • Material: Made of high-quality fire-clay with a smooth, durable glaze to ensure hygiene and ease of cleaning.
  • Pattern and Size: Specific patterns and sizes are prescribed to accommodate standard bed pans comfortably.
  • Dimensions & Tolerances: Precise dimensional tolerances are mandated to ensure interchangeability and proper fit.
  • Surface Finish: The glazed surface must be smooth, free from cracks, blisters, or imperfections to prevent bacterial growth.
  • Strength: The sink must withstand typical hospital use without chipping or breaking.
  • Design: Should facilitate easy drainage and cleaning, with rounded edges to avoid injury and accumulation of dirt.

Summary Table:

FeatureRequirement
MaterialFire-clay with glaze
Size & PatternStandardized for bed pan compatibility
Surface FinishSmooth, impervious glaze
Dimensional ToleranceStrict adherence as per IS specifications
DurabilityResistant to chipping and cracking
DesignRounded edges, easy drainage and cleaning

These features ensure safety, hygiene, and functionality in hospital settings.

?How should the flushing rim and water inlets be designed according to this standard?

According to IS 771 Part 6 (Clause 2.3.2) for glazed fire-clay sanitary appliances (bed pan sinks):

  • The flushing rim must have adequate holes to ensure flushing covers the entire interior surface of the bowl.
  • A water inlet socket should be located centrally on the top face of the rim.
  • Additionally, there must be a water inlet hole on the top side wall of the pan for connection to a water sprayer.

Key Design Points:

  • Flushing rim holes: distributed to cover the whole bowl interior.
  • Water inlet socket: central on rim top face.
  • Secondary water inlet hole: on the top side wall for sprayer connection.

This ensures efficient and hygienic flushing of the pan interior.

Loading diagram...

This layout guarantees thorough flushing and easy water sprayer connection.

?What are the requirements for waste outlet connections in bed pan sinks?

According to IS 771 Part 6, the requirements for waste outlet connections in bed pan sinks are:

  • The inside surface of the pan must be uniform and smooth with a circular waste hole at one end for drainage.
  • The main waste outlet must have a flanged connection with four holes to connect securely to the trap.
  • There must be a second waste outlet of 30 mm diameter, connected to a waste pipe for additional drainage.
  • The bed pan sink is of two-piece construction: the sink and the outlet trap.
  • Dimensions should conform to Fig. 1 of the code (not provided here).

Summary Table:

FeatureRequirement
Main waste outletCircular hole with flange & 4 holes
Secondary waste outlet30 mm diameter, connected to waste pipe
ConstructionTwo-piece (sink + outlet trap)
SurfaceUniform, smooth inside surface

This ensures efficient drainage and easy trap connection for hygiene and maintenance.

?How does IS 771 Part 6 ensure the quality and hygiene of bed pan sinks?

IS 771 Part 6 ensures quality and hygiene of bed pan sinks by specifying:

  • Material: Use of glazed fire-clay, which is non-porous and resistant to staining and bacterial growth.
  • Construction & Dimensions: Detailed patterns, sizes, and dimensional tolerances to ensure proper fit and usability.
  • Surface Finish: Smooth glazed surfaces facilitate easy cleaning and prevent contamination.
  • Durability: Fire-clay offers thermal resistance and mechanical strength, enhancing longevity and hygiene.
  • Standardization: Uniform requirements reduce variability, ensuring consistent quality across manufacturers.

These criteria collectively ensure bed pan sinks are hygienic, easy to clean, and durable, minimizing infection risks in healthcare settings.

Loading diagram...

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 771 Part 6. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required