IS 6932 Part 111983AI Search Enabled✦ AI Generated

Methods of Tests for Building Limes, Part 11: Determination of Setting Time of Hydrated Lime

IS 6932 Part 11:1983 specifies the standardized method for determining the initial and final setting times of hydrated lime used in building construction. This standard is essential for quality control and ensures that hydrated lime meets performance criteria for setting behavior under controlled temperature and humidity conditions. It applies primarily to engineers, quality inspectors, and manufacturers involved in the production and testing of building limes.

8Sections
25Clauses Indexed
AI Search Ready
1983Edition
Building Limes and Gypsum ProductsCategory
Alternative search terms: IS 6932 Part 11 PDF, IS 6932 Part 11 pdf free download, IS 6932 Part 11 free download pdf, IS6932Part11 PDF, IS-6932-Part-11 PDF, IS 6932 Part 11 1983 PDF, IS 6932 Part 11:1983 PDF, IS 6932 Part 11-1983 PDF, IS 6932 Part 11 (1983) PDF, IS 6932 Part 11 1983 edition PDF, IS 6932 Part 11 edition 1983 PDF

What This Standard Covers

IS 6932 Part 11:1983 specifies the standardized method for determining the initial and final setting times of hydrated lime used in building construction. This standard is essential for quality control and ensures that hydrated lime meets performance criteria for setting behavior under controlled temperature and humidity conditions. It applies primarily to engineers, quality inspectors, and manufacturers involved in the production and testing of building limes.

Who Uses This Standard

  • Civil Engineers
  • Materials Testing Laboratory Technicians
  • Quality Control Engineers
  • Construction Project Managers
  • Lime Manufacturers
  • Building Material Researchers
  • Standards Compliance Officers

Key Topics Covered

Preparation of hydrated lime test samples
Use of Vicat apparatus for setting time measurement
Determination of initial setting time
Determination of final setting time
Test conditions including temperature and humidity requirements
Sample gauging and handling procedures
Measurement techniques for needle penetration
Handling of surface scum during testing
Reference to related IS standards for apparatus and rounding rules
Reporting and rounding off test results
Quality assurance in building lime testing

Table of Contents

1Scope

IS 6932 Part 11: Scope & Key Specifications for Setting Time of Hydrated Lime

Scope:
This part covers the determination of the setting time of hydrated lime using the Vicat apparatus.


Key Specifications & Procedures:

  • Apparatus:

    • Use Vicat apparatus with a needle (C) replaced by a needle with annular attachment (F) for final setting time (Clause 3.3).
  • Final Setting Time:

    • Defined as the time when the needle makes an impression on the lime surface, but the annular attachment does not.
    • If scum forms, test the underside of the block.
  • Environmental Conditions (Clause 3.1.2):

    • Temperature of lime, water, and test room: 27 ± 2°C
    • Relative humidity: ≥ 90%
    • Avoid draughts.

Summary Table:

ParameterValue/Condition
Test temperature27 ± 2°C
Relative humidity≥ 90%
Apparatus needleNeedle with annular attachment (for final setting)
Final setting time criteriaNeedle impression without annular attachment impression

This ensures standardized and reliable measurement of hydrated lime setting time per IS 6932 Part 11.

2References

IS 6932 (Part 11) - 1983: Determination of Setting Time of Hydrated Lime

Key Specification (Clause 3.3 - Final Setting Time)

  • Use Vicat apparatus with annular needle attachment (F) replacing standard needle (C).
  • Final setting time is when:
    • The needle makes an impression on the lime surface.
    • The annular attachment fails to make an impression.
  • If scum forms on the surface, test on the underside of the test block.

References & Amendments

  • Vicat apparatus specification: IS 5513:1996 (updated from IS 4031-1968).
  • Methods align with IS 4031 (Part 5): 1988 for initial/final setting times of hydraulic cement.
  • Results rounding as per IS 2-1960.

Summary Table for Setting Time Test Apparatus

Apparatus ComponentDescription
Needle (C)Standard penetration needle
Annular Attachment (F)Ring-shaped attachment for final set

Practical Notes:

  • Final setting time indicates the lime's transition from plastic to solid state.
  • Use gentle application to avoid false impressions.
  • Testing underside avoids surface anomalies like scum.
flowchart TD
    A[Vicat Apparatus] --> B[Needle (C)]
    A --> C[Annular Attachment (F)]
    B --> D{Impression on surface?}
    D -- Yes --> E[Check annular attachment]
    E --> F{Annular makes impression?}
    F -- No --> G[Final Setting Time reached]
    F -- Yes --> H[Not final set]
    D -- No --> H

This method ensures consistent determination of hydrated lime's final setting time as per IS 6932 (Part 11).

3Apparatus

Apparatus as per IS 6932 Part 11

1. Vicat Apparatus (IS: 5513-1976)

  • Used for determining setting times of lime.
  • For final setting time, replace the standard needle (C) with a needle having an annular attachment (F).

2. Environmental Conditions for Testing (Clause 3.1.2)

  • Temperature: 27 ± 2℃
  • Relative Humidity: ≥ 90%
  • Avoid draughts during testing.

3. Determination of Final Setting Time (Clause 3.3)

  • Apply the annular needle gently on the test block surface.
  • Final set when the needle makes an impression but the annular attachment does not.
  • If scum forms, test the underside of the block.

Summary Table: Vicat Needle Types

Needle TypeUse
Needle CInitial setting time
Needle FFinal setting time (annular)

flowchart LR
    A[Lime Test Block] --> B[Vicat Apparatus]
    B --> C{Needle Type}
    C -->|C| D[Initial Setting Time]
    C -->|F (Annular)| E[Final Setting Time]
    E --> F{Impression on surface?}
    F -->|Yes| G[Final set reached]
    F -->|No| H[Not set yet]

Note: Use clean appliances and maintain specified temperature and humidity for accurate results.

4Preparation of Test Sample

IS 6932 Part 11: Preparation of Test Sample for Building Limes

Key Specifications & Conditions:

  • Sample Form: Putty, prepared as per Clause 3.2.4 of IS 6932 (Part 8) - 1973.
  • Appliances: Must be clean for gauging.
  • Temperature Control: Lime, water, and test room temperature at 27 ± 2°C.
  • Humidity: At least 90% relative humidity.
  • Environment: Away from drafts.

Preparation Summary:

  1. Mix lime and water to form putty (refer IS 6932 Part 8 for workability method).
  2. Maintain temperature and humidity conditions strictly during preparation and testing.
  3. Use clean tools to avoid contamination.

Final Setting Time (Clause 3.3):

  • Use Vicat apparatus with annular needle attachment.
  • Final setting time is when the needle makes an impression but the annular attachment does not.
  • If scum forms, test on the underside of the block.

Quick Reference Table: Vicat Apparatus Needles

Needle TypePurpose
Needle (C)Initial setting time
Needle with annular (F)Final setting time

flowchart TD
    A[Prepare Lime Putty] --> B[Maintain 27 ± 2°C & 90% RH]
    B --> C[Use Clean Appliances]
    C --> D[Fill Vicat Mould]
    D --> E{Test Setting Time}
    E -->|Initial| F[Needle (C)]
    E -->|Final| G[Needle with Annular (F)]
    G --> H[Final Setting Time Determined]

For detailed mixing ratios and workability, refer IS 6932 Part 8 (Clause 3.2.4).

5Determination of Initial Setting Time

IS 6932 Part 11: Determination of Initial Setting Time of Hydrated Lime

Key Specification (Clause 3.2)

  • Prepare test block as per Clause 3.1.
  • Place block under needle-bearing rod (needle C).
  • Lower needle gently to touch surface, then release quickly.
  • Initially, needle fully pierces block.
  • Repeat until needle fails to pierce block by 5 ± 0.5 mm from mould bottom.
  • Initial Setting Time = Time from water addition to needle failing to pierce by 5 ± 0.5 mm.

Summary Table for Needle Penetration

Penetration Depth (mm)Interpretation
> 5 ± 0.5Lime not set yet
≤ 5 ± 0.5Initial setting reached

Notes:

  • The test is manual; repeat measurements at intervals.
  • Time recorded in minutes from mixing water with lime.
  • Ensures consistency in lime setting behavior for construction use.
flowchart TD
    A[Add water to lime] --> B[Prepare test block]
    B --> C[Lower needle on block surface]
    C --> D{Needle penetration > 5 ± 0.5 mm?}
    D -- Yes --> E[Repeat test after interval]
    D -- No --> F[Record elapsed time as Initial Setting Time]

This method ensures reliable determination of hydrated lime's initial setting time per IS 6932-11.

6Determination of Final Setting Time

IS 6932 Part 11: Determination of Final Setting Time of Hydrated Lime

Key Specification (Clause 3.3):

  • Use Vicat apparatus with needle having annular attachment (F) replacing the standard needle (C).
  • Final setting time is the time elapsed from mixing water with lime until:
    • The needle makes an impression on the test block surface,
    • While the annular attachment fails to make an impression.
  • If a scum forms on the surface, test on the underside of the test block.

Summary of Procedure:

StepDescription
Prepare test blockAs per Clause 3.1
Use Vicat apparatusReplace needle with annular attachment
Apply needle gentlyNeedle should make impression
Check annular attachmentShould not make impression
Record timeTime at which above condition is met = Final Setting Time

Important Notes:

  • Final setting time indicates the lime has hardened sufficiently to resist penetration by the annular ring.
  • This test complements initial setting time (needle penetration of 5 ± 0.5 mm).

Diagram of Vicat Needle Setup:

graph LR
A[Vicat Apparatus] --> B[Standard Needle (C)]
A --> C[Annular Attachment (F)]
B --> D[Penetrates test block surface]
C --> E[No impression on surface at final set]

This method ensures accurate determination of the final setting time critical for quality control of hydrated lime in construction.

7Test Conditions

IS 6932 Part 11 - Test Conditions Summary

Key Test Conditions (Clause 3.1.2)

  • Temperature: 27 ± 2°C for lime, water, and test room.
  • Relative Humidity: Minimum 90%.
  • Environment: Away from draughts.
  • Appliances: Must be clean for gauging.

Apparatus for Final Setting Time (Clause 3.3)

  • Use Vicat apparatus with an annular attachment on the needle.
  • Final Setting Time: When needle makes an impression but annular attachment does not.
  • If scum forms, test underside of block.

Preparation (Clause 3.1)

  • Sample in putty form as per IS 6932 Part 8 (workability determination).

Summary Table: Test Environment Parameters

ParameterValue
Temperature27 ± 2 °C
Relative Humidity≥ 90%
Air MovementNo draughts
Sample FormPutty (IS 6932 Pt.8)

flowchart TD
    A[Test Preparation] --> B[Maintain Temp 27±2°C]
    B --> C[Maintain RH ≥ 90%]
    C --> D[Use Clean Appliances]
    D --> E[Perform Test with Vicat Needle + Annular Attachment]
    E --> F{Needle impression?}
    F -- Yes, Attachment no impression --> G[Final Setting Time Recorded]
    F -- No --> H[Continue Testing]

This ensures consistent, reliable lime setting time measurements per IS 6932 Part 11.

8Reporting of Results

IS 6932 (Part 11) - Reporting of Results for Setting Time of Hydrated Lime

Key Specifications for Reporting:

  • Final Setting Time is determined using the Vicat apparatus with an annular needle attachment.
  • The lime is considered finally set when:
    • The needle makes an impression on the test block surface,
    • While the annular attachment fails to do so.
  • If a scum forms on the surface, use the underside of the test block for determination.
  • Testing conditions:
    • Temperature of lime, water, and test room: 27 ± 2°C
    • Relative humidity: ≥ 90%
    • Avoid draughts during testing.
  • Use clean appliances for gauging.
  • Results should be rounded off as per IS 2-1960.

Summary Table for Final Setting Time Determination:

ParameterSpecification
Temperature27 ± 2°C
Relative Humidity≥ 90%
Apparatus NeedleNeedle with annular attachment (Vicat)
Impression CriterionNeedle makes impression; annular attachment does not
Surface for TestTop surface or underside if scum forms
Rounding OffAs per IS 2-1960

flowchart TD
    A[Test Block Preparation] --> B[Apply Needle with Annular Attachment]
    B --> C{Does Needle Make Impression?}
    C -- Yes --> D{Does Annular Attachment Make Impression?}
    D -- No --> E[Record Final Setting Time]
    D -- Yes --> F[Continue Testing]
    C -- No --> F
    F --> B

This ensures standardized and reproducible reporting of setting time results per IS 6932 (Part 11).

Popular Questions About IS 6932 Part 11

?What apparatus is specified for determining the setting time of hydrated lime?

Apparatus for Determining Setting Time of Hydrated Lime (IS 6932 Part 11):

  • Penetration Needle and Rod Assembly:
    A needle mounted on a rod (referred to as the "needle (C)" in the code) is used to test the setting time by penetration.

  • Mould:
    To prepare the test block of hydrated lime paste.

Test Principle:

  • The needle is gently lowered onto the surface of the lime test block and released to penetrate it.
  • Initially, the needle fully pierces the block.
  • The initial setting time is recorded when the needle fails to penetrate 5 ± 0.5 mm into the block.

Summary of Procedure:

StepDescription
Prepare test blockAccording to IS 6932-11 Clause 3.1
Use needle on rod assemblyLower gently, release to penetrate lime block
Measure penetration depthInitial setting time = time when penetration ≤ 5 ± 0.5 mm

Loading diagram...

This apparatus and method ensure consistent, repeatable determination of hydrated lime setting time as per IS 6932 Part 11.

?How is the initial setting time of hydrated lime defined and measured?

Initial Setting Time of Hydrated Lime (IS 6932 Part 11)

  • Definition: The initial setting time is the duration from the moment water is added to hydrated lime until the test needle fails to penetrate the test block by 5 ± 0.5 mm.

  • Measurement Procedure (Clause 3.2):

    1. Prepare the test block as per Clause 3.1.
    2. Place the test block under the needle rod.
    3. Gently lower the needle to touch the block surface and quickly release it, allowing penetration.
    4. Initially, the needle fully pierces the block.
    5. Repeat until the needle no longer penetrates beyond 5 ± 0.5 mm from the bottom of the mould.
    6. The elapsed time from mixing water with lime to this point is recorded as the initial setting time.

This method ensures a consistent, reproducible measure of setting behavior for hydrated lime.

?What are the environmental conditions required during testing?

According to IS 6932 Part 11 (Clause 3.1.2), the environmental conditions during testing of building lime are:

  • Temperature: 27 ± 2°C for lime, water, and test room
  • Relative Humidity: At least 90%
  • Atmosphere: Away from drafts to prevent drying or cooling effects
  • Clean Appliances: Must be used for gauging

These conditions ensure consistency and reliability in test results, especially for setting time and workability tests.


Summary Table

ParameterRequired Value
Temperature27 ± 2°C
Relative Humidity≥ 90%
Air MovementNo drafts (still air)
EquipmentClean appliances

Maintaining these conditions is critical for accurate determination of lime properties as per IS 6932 Part 11.

?How is the final setting time determined using the Vicat apparatus?

According to IS 6932 Part 11, the final setting time using the Vicat apparatus is determined as follows:

  • Replace the standard needle (C) with the needle having an annular attachment (F).
  • Gently apply this needle to the surface of the lime test block.
  • The lime is considered finally set when:
    • The needle (without attachment) makes an impression on the surface,
    • But the needle with the annular attachment fails to make an impression.
  • If a scum forms on the surface, test the underside of the block.

Summary:

StepAction
Use Vicat apparatusNeedle with annular attachment (F)
Test surfaceApply needle gently
Final set criteriaNeedle makes impression; annular attachment does not

This method ensures precise detection of the final setting stage of lime.

Loading diagram...
?What procedures should be followed if a scum forms on the lime test sample surface?

IS 6932 Part 11 does not explicitly mention procedures for scum formation on the lime test sample surface during setting time tests.

Recommended procedure (engineering practice):

  • Remove scum gently with a clean spatula or brush without disturbing the underlying test block.
  • Ensure test block surface is smooth and uniform before needle penetration.
  • Maintain test conditions strictly: temperature 27 ± 2℃, humidity ≥ 90%, no drafts (Clause 3.1.2).
  • If scum persists, prepare a fresh test sample to avoid erroneous initial setting time results.
  • Document any scum occurrence and corrective action for test validity.

This ensures accurate needle penetration readings and reliable initial setting time per Clause 3.2.

Loading diagram...

Summary: Remove scum carefully or redo the sample to maintain test accuracy.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 6932 Part 11. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required