IS 60741971AI Search Enabled✦ AI Generated

Code of Practice for Functional Requirements of hotels, restaurants and other food service establishments Daylighting of Factory Buildings

IS 6074:1971 is the Indian Standard code of practice that outlines the functional requirements for hotels, restaurants, and other food service establishments to ensure hygienic conditions, safety, and operational efficiency. It provides guidelines on licensing, building design, sanitation, water supply, food handling, fire safety, and employee health, aimed at municipal authorities, food service operators, and architects involved in establishing or regulating food service premises.

15Sections
173Clauses Indexed
AI Search Ready
1971Edition
Functional Requirements in BuildingsCategory
Alternative search terms: IS 6074 PDF, IS 6074 pdf free download, IS 6074 free download pdf, IS6074 PDF, IS-6074 PDF, IS 6074 1971 PDF, IS 6074:1971 PDF, IS 6074-1971 PDF, IS 6074 (1971) PDF, IS 6074 1971 edition PDF, IS 6074 edition 1971 PDF

What This Standard Covers

IS 6074:1971 is the Indian Standard code of practice that outlines the functional requirements for hotels, restaurants, and other food service establishments to ensure hygienic conditions, safety, and operational efficiency. It provides guidelines on licensing, building design, sanitation, water supply, food handling, fire safety, and employee health, aimed at municipal authorities, food service operators, and architects involved in establishing or regulating food service premises.

Who Uses This Standard

  • Food Service Establishment Operators
  • Municipal Licensing Authorities
  • Architects and Building Designers
  • Health and Safety Inspectors
  • Facility Managers
  • Sanitation Engineers
  • Fire Safety Officers

Key Topics Covered

Licensing and regulatory compliance
Site location and environmental hygiene
Building design and materials for hygiene
Water supply and storage requirements
Drainage and sanitation fitments
Kitchen layout and equipment hygiene
Food handling and contamination prevention
Employee health and medical examination
Fire safety and emergency exits
Waste disposal and vermin control
Uniform and personal hygiene standards
Storage and cleaning of utensils
Dining hall requirements
First-aid and fire-fighting equipment
Compliance with local byelaws and food safety acts

Table of Contents

1Scope

IS 6074: Scope Overview

  • Scope Definition: IS 6074 covers specifications for fitments used in drainage and sanitation systems in buildings, ensuring compatibility and performance.
  • Functional Requirements: Aligns with the Functional Requirements in Buildings (Sectional Committee BDC 12), focusing on fitments that meet sanitation and drainage needs.
  • International Coordination: The standard harmonizes Indian practices with international standards for global relevance and local applicability.

Key References in IS 6074

ClauseDescription
2.0Definitions relevant to drainage fitments
14.1.1Fitment requirements as per Tables 4 & 5

Tables 4 & 5 (Summary)

  • Table 4: Specifications for various types of drainage fitments (dimensions, materials, tolerances).
  • Table 5: Performance criteria (load capacity, water tightness, durability).

Important Notes

  • Fitments must ensure leak-proof joints, adequate flow capacity, and resistance to corrosion.
  • Materials typically include PVC, cast iron, and HDPE depending on application.
flowchart TD
    A[IS 6074 Scope] --> B[Drainage Fitments]
    B --> C[Material Specifications]
    B --> D[Dimensional Standards]
    B --> E[Performance Criteria]
    E --> F[Leak-proof]
    E --> G[Load Capacity]
    E --> H[Durability]

For detailed dimensions and performance values, refer directly to Tables 4 & 5 in IS 6074.

2Definitions

IS 6074: Key Definitions & Specifications

1. Definitions (Clause 2.0)

  • The standard applies specific definitions for terms related to drainage, sanitation, ventilation, lighting, and water supply to maintain uniformity.

2. Ventilation Requirements (Clause 12.1, Table 2)

AreaAir Changes per Hour (ACH)
Living rooms3
Dining & lounge2 - 3
Big kitchen12
Small kitchen6
Toilets6

3. Lighting Specifications (Clause 11.1, Table 1)

AreaIllumination (Lux)
Entrance150
Reception & accounts300
Dining rooms (tables)100
Lounges150
Bedrooms (general)100
Bedrooms (dressing etc.)200
Writing rooms (tables)300
Corridors70
Stairs100
Laundries200
Kitchens200+ (supplementary local lighting recommended)
Goods & passenger lifts70
Clockrooms & toilets200+
Self service counters300

4. Fitments for Drainage & Sanitation (Clause 14.1.1)

  • Must conform to Tables 4 and 5 (not provided here).

Summary:

  • Ventilation: Minimum ACH varies by room type to ensure air quality.
  • Lighting: Lux levels specified for functional and aesthetic needs.
  • Fitments: Must comply with specific tables ensuring sanitary standards.
flowchart TD
    A[IS 6074 Standard] --> B[Definitions (Clause 2.0)]
    A --> C[Ventilation (Clause 12.1)]
    A --> D[Lighting (Clause 11.1)]
    A --> E[Fitments (Clause 14.1.1)]
    C --> F[Table 2: Air Changes per Hour]
    D --> G[Table 1: Illumination
3Licensing and Obligations of Licensee

IS 6074: Licensing and Obligations of Licensee — Key Points

1. Application for License (Clause 3.1)

  • Intending licensee must apply using the prescribed form (see Appendix A).
  • Application must include a layout plan showing:
    • Location of premises
    • Approach routes
    • Distance from public sewerage, lavatories, urinals nearby

2. Compliance Limits (Clause 3.1.3)

  • Licensee must not exceed or violate the particulars mentioned in Appendix A for which the license is granted.

3. Display and Inspection (Clause 3.1.5)

  • License form and any related conditions must be displayed visibly at the licensed premises.
  • Must be produced for inspection by authorities on demand.

4. Definition (Clause 2.3)

  • Licensee: A person or entity licensed to operate the establishment.

Summary Table: Licensee Obligations

ObligationDescription
Application formUse prescribed form + layout plan
ComplianceAdhere strictly to license particulars
DisplayLicense & conditions visible at premises
InspectionProduce license on authority’s request

Note: Always refer to Appendix A of IS 6074 for the exact application format and detailed particulars.

4Building Requirements

IS 6074: Building Requirements - Key Specifications

1. Ventilation Requirements (Clause 12.1)

For Non-Airconditioned Buildings, minimum air changes per hour (ACH) are:

Space TypeAir Changes per Hour (ACH)
Living rooms3
Dining & lounge2 to 3
Big kitchen12
Small kitchen6
Toilets6

These values ensure adequate natural ventilation for health and comfort.


2. Water Supply

  • Refer to IS 1256-1967 for detailed water supply provisions in building byelaws.

Additional Notes:

  • For Air-conditioned buildings, mechanical ventilation standards must be followed as per Table 2 (not fully detailed here).
  • Building bye-laws (BDC 25) cover minimum provisions for safety, ventilation, and water supply.

flowchart TD
    A[Building Requirements] --> B[Ventilation]
    B --> C[Non-Airconditioned]
    C --> D[Living rooms: 3 ACH]
    C --> E[Dining & lounge: 2-3 ACH]
    C --> F[Big kitchen: 12 ACH]
    C --> G[Small kitchen: 6 ACH]
    C --> H[Toilets: 6 ACH]
    A --> I[Water Supply]
    I --> J[IS 1256-1967 Compliance]

Summary: Ensure minimum ventilation per space type and comply with IS 1256 for water supply.

5Location and Environmental Hygiene

IS 6074: Location and Environmental Hygiene - Key Specifications

1. Illumination (Clause 11.1, Table 1)

Recommended illumination levels (Lux) for various areas:

AreaIllumination (Lux)
Entrance150
Reception & Accounts300
Dining room (tables)100
Lounges150
Bedrooms (general)100
Bedrooms (dressing tables)200
Writing rooms (tables)300
Corridors70
Stairs100
Laundries200
Kitchens200+ (supplementary local lighting recommended)
Goods & passenger lifts70
Clockrooms & toilets200+
Self-service counters300

2. Ventilation (Clause 12.1, Table 2)

Minimum air changes per hour (ACH) for non-air-conditioned buildings:

AreaAir Changes per Hour (ACH)
Living rooms3
Dining & lounge2-3
Big kitchen12
Small kitchen6
Toilets6

3. Water Supply & Sanitation (Clause 14.1.1, Table 4)

Minimum drainage and sanitation fitments:

  • Water-closets: 1 per 8 persons (residential), 1 per 100 persons (public)
  • Ablution taps: 1 per water closet
  • Urinals: 1 per 50 males (public)
  • Wash basins: 1 per 10 persons (residential), 1 per water closet (public)
  • Baths: 1 per 10 persons (residential)
  • Slop sinks: 1 per 30 bedrooms (minimum 1 per floor)
  • Kitchen sinks: 1 in each kitchen

Notes:

  • Supplementary lighting recommended over kitchen equipment and mirrors.
  • Exhaust fans in kitchens should have grease filters.
  • Hygiene and functional requirements prioritize user safety and comfort
6Compliance with Local Byelaws

IS 6074: Compliance with Local Byelaws - Key Points

  1. Application for License (Clause 3.1):

    • Intending licensee must apply on the prescribed form (see Appendix A).
    • Application must include a layout plan showing:
      • Location of the site
      • Approach routes
      • Distance from public sewerage systems, lavatories, urinals nearby
  2. Authority Having Jurisdiction (Clause 2.4):

    • Local body or authorized committee/official acts as the Competent Authority for grant and enforcement.
  3. Rounding Off Numerical Values:

    • Follow rules as per IS 1256-1967 (Code of Building Byelaws) for consistent rounding in measurements.

Practical Checklist for Compliance

RequirementDetails
Application FormAs per Appendix A of IS 6074
Layout PlanLocation, approach, distance from public facilities
AuthorityLocal body or authorized official
Measurement RoundingAs per IS 1256-1967

Summary Diagram

flowchart TD
    A[Intending Licensee] --> B[Prepare Application Form]
    B --> C[Include Layout Plan]
    C --> D[Submit to Competent Authority]
    D --> E[Review & Grant License]

Note: Always verify local byelaws for additional specific requirements beyond IS 6074.

7Walls, Ceilings, Doors and Windows

IS 6074 Key Specifications for Walls, Ceilings, Doors, and Windows


1. Ceilings (Clause 9.1)

  • Must be clean, leak-proof, smooth, and non-absorbent.
  • Free from cracks and crevices to prevent vermin.
  • Surface should facilitate easy cleaning.

2. Doors and Windows (Clause 10 & 12)

  • Functional requirements as per BDC 12.
  • Ventilation Standards for Non-Airconditioned Buildings (Table 2, Clause 12.1):
AreaAir Changes per Hour
Living rooms3
Dining & lounge2-3
Big kitchen12
Small kitchen6
Toilets6

3. Illumination Requirements (Clause 11.1, Table 1)

AreaIllumination (Lux)
Entrance150
Reception/accounts300
Dining rooms (tables)100
Lounges150
Bedrooms (general)100
Bedrooms (dressing)200
Writing rooms (tables)300
Corridors70
Stairs100
Kitchens200+ (local lighting recommended)
Toilets200+

Summary Diagram: Ventilation & Illumination Relation

flowchart LR
    A[Rooms] --> B[Ventilation Requirements]
    A --> C[Illumination Requirements]
    B -->|Living Room| D[3 ACH]
    B -->|Kitchen| E[6-12 ACH]
    C -->|Reception| F[300 Lux]
    C -->|Kitchen| G[200+ Lux]

Note:

  • ACH = Air Changes per Hour
  • Lux = Illumination level
  • Local supplementary lighting recommended in kitchens and mirrors.

For detailed structural design of walls, refer to IS 456 and IS 1905 for masonry. IS 6074 focuses on functional and environmental requirements.

8Water Supply and Storage

IS 6074: Water Supply & Storage - Key Points

1. Water Supply Requirements (Clause 13.1.1, Table 3)

DescriptionNon-Airconditioned (L/day)Airconditioned (L/day)
Hotels (per bed)180275
Restaurants (per seat)7097
  • Note: For hotels with laundry, add 120 L/bed/day extra.

2. Water Storage Specifications (Clause 13.2)

  • Use galvanized iron or suitable material tanks.
  • Tanks must have:
    • Tight-fitting lids
    • Screw caps at the bottom for drainage
  • Tanks should be on elevated platforms for maintenance.
  • Regular inspection and cleaning required.

Summary Diagram

flowchart TD
    A[Water Supply] --> B[Hotels: 180/275 L per bed]
    A --> C[Restaurants: 70/97 L per seat]
    B --> D[+120 L/bed if laundry]
    E[Water Storage] --> F[Galvanized Iron Tanks]
    F --> G[Tight lids & bottom screw caps]
    F --> H[Elevated platform]
    F --> I[Regular cleaning & inspection]

This ensures adequate water quantity and hygienic storage per IS 6074 standards.

9Drainage and Sanitation Fitments

IS 6074: Drainage and Sanitation Fitments - Key Specifications

1. Fitment Requirements (Clause 14.1.1, Tables 4 & 5)

FitmentHotels (Residential & Staff)Restaurants (Public & Staff)
Water-Closets1 per 8 persons (min 2 if both sexes lodged)1 per 50 seats up to 200; add 1 per 100 seats over 200
Ablution Taps1 in each water-closet; 1 tap per 50 persons near WCs & urinalsSame as hotels
Urinals1 per 50 persons (public males); none for females1 per 50 seats (male public); nil for females
Wash Basins1 per 10 persons (excluding room basins)1 per water-closet and urinal
Baths1 per 10 persons (excluding en-suite baths)Not specified
Slop Sinks1 per 30 bedrooms, minimum 1 per floor1 in restaurant
Kitchen Sinks & Dishwashers1 in each kitchen4 in restaurants

2. Additional Notes

  • Water closets may be European style.
  • Assume 2/3 males, 1/3 females for calculations.
  • Exhaust fans in kitchens must have grease filters (Clause 15.3).
  • Drain boards/trays must be impervious and corrosion-resistant (Clause 18.2).

3. Hand Dishwashing Sink (Fig. 1 & 2)

  • Water Temperatures:
    • Wash water with detergent: 43º-49ºC
    • Rinse water: Warm
    • Sterilize water: 77ºC for 2 minutes
  • Design:
    • Integral drainboards pitched min 1:100 toward sinks
    • 15 mm coved internal corners (no sharp solder fillets)
    • Removable strainer basket and swivel neck faucets

flowchart LR
    A[Number of Persons/Seats] --> B{Type
10Kitchen Design and Equipment

IS 6074 Key Points on Kitchen Design & Equipment

1. Kitchen Space (Clause 15.1)

  • Minimum floor area: 0.5 m² per diner.
  • Snack bars and soda fountains' service area counted as kitchen space.
  • Mobile catering excluded.

2. Exhaust Fans (Clause 15.3)

  • Must have grease filters to collect grease.

3. Sanitation Fitments (Tables from Clauses 14.1.1 & 15.3)

FitmentResidential/Public/StaffRestaurants (per seats)
Water-closets1 per 8 persons (min 2)1 per 50 seats (up to 200), then 1 per 100 seats
Ablution taps1 per water-closet1 per water-closet + 1 tap per 50 persons nearby
Urinals (males)1 per 50 persons1 per 50 seats
Wash basins1 per 10 persons1 per water-closet/urinal
Kitchen sinks/dishwashers1 per kitchen4 per kitchen
Slop sinks1 per 30 bedrooms (min 1 floor)1 per restaurant

4. Kitchen Sink & Dishwashing (Clause 18.2 & Figures)

  • Impervious, corrosion-resistant surfaces.
  • Sink bowls with 15 mm coved internal corners (no solder fillets).
  • Drainboards pitched 1 in 100 towards sinks.
  • Water temps for washing:
    • Wash: 43-49°C with detergent
    • Rinse: Warm water
    • Sterilize: 77°C for 2 minutes

5. Hand Dishwashing Setup (Fig.1 & 2)

  • Includes wash, rinse, sterilize bowls.
  • Swivel neck faucets with holes.
  • Adjustable feet and tubular bracing.

flowchart TD
    A[Kitchen Design] --> B[Space: 0.5 m²/diner]
    A --> C[Exhaust Fans with Grease Filters]
    A --> D[Sanitation Fitments]
    D -->
11Food Handling and Storage

IS 6074: Food Handling and Storage – Key Specifications

1. Storage Temperatures for Perishable Food (Clause 19.1, Table 6)

Food ItemStorage Temperature (ºC)
Meat, meat products, poultry0.00 to 1.50
Fresh fish and seafood-2.00 to -0.50
Dairy products and eggs0.50 to 2.50
Fresh fruit and vegetables2.00 to 4.50
Ice-creams-14.50 to -12.00
  • Note: Potatoes require no refrigeration but must be stored away from light.
  • Fish and seafood must be stored in separate compartments to avoid contamination.

2. Food Handling Hygiene (Clause 24.3)

  • Avoid manual contact with food or drink as far as possible.
  • Serving sliced butter and cracked ice must not involve direct finger contact.

3. General Hygiene (Clause 25)

  • Basic hygiene principles apply to all food service establishments.
  • Structural aspects are not covered; focus is on functional requirements.

Summary Diagram: Food Storage Temperature Zones

graph LR
    A[Meat, Poultry] -->|0 to 1.5°C| B[Cold Storage]
    C[Fish & Seafood] -->|-2 to -0.5°C| D[Freezer Compartment]
    E[Dairy & Eggs] -->|0.5 to 2.5°C| B
    F[Fruits & Vegetables] -->|2 to 4.5°C| B
    G[Ice-creams] -->|-14.5 to -12°C| D

Ensure strict temperature control and hygienic handling to minimize contamination risks in food service establishments.

12Employee Health and Hygiene

IS 6074: Employee Health and Hygiene Key Points

  • Medical Examination (Clause 26.1):

    • Initial and annual medical check-up by registered medical practitioner.
    • Includes chest X-ray (tuberculosis), stool exam (protozoal/helminthic parasites, Salmonella, Shigella, Vibrio cholerae), urine, and blood tests (venereal diseases).
  • Personal Hygiene (Clause 26.2):

    • Fingernails must be short and clean.
    • Hands washed with soap/detergent before work and after absences, especially post-sanitary use.
    • Use clean towels for drying hands.
    • No contact of hands/body/clothing with food to prevent microbial contamination.
  • Vaccination (Clause 26.3):

    • Mandatory typhoid and paratyphoid A inoculation on appointment and every 5 years thereafter.
    • During epidemics, all workers must be inoculated.
    • Maintain inoculation records.

Summary Table:

RequirementFrequency/Notes
Medical ExaminationInitial + annually or as needed
Hand WashingBefore work, after absences
Fingernail HygieneAlways short and clean
VaccinationOn appointment + every 5 years; epidemic-based booster
Record KeepingMaintain inoculation and medical exam records
flowchart LR
    A[Employee Appointment] --> B[Medical Exam]
    B --> C[Vaccination: Typhoid & Paratyphoid A]
    C --> D[Start Work]
    D --> E[Daily Hygiene Practices]
    E --> F[Annual Medical Exam]
    F --> G[Periodic Vaccination (5 years)]

This ensures food safety by minimizing microbial contamination risks through strict employee health monitoring and hygiene.

13Dining Hall Requirements

IS 6074: Dining Hall & Kitchen Space Requirements

Key Specifications:

  • Dining Hall Area (Clause 16.1):

    • Minimum 1 m² per diner (excluding service counters, furniture except tables & chairs).
    • Table surfaces must be non-absorbent, impervious material unless table linen is used.
  • Kitchen Area (Clause 15.1):

    • Minimum 0.5 m² per diner to ensure spaciousness proportional to diners served.
    • Service/dispensing areas (snack bars, soda fountains) included as kitchen space.
  • Worker Facilities (Clause 15.7):

    • Provision of changing rooms with independent wash & toilet facilities.
    • Lockers for personal effects recommended.

Summary Table:

Space TypeArea per Diner (m²)Notes
Dining Hall1.0Excludes service counters & fixtures except tables/chairs
Kitchen0.5Includes service/dispensing areas
Worker Changing RoomAs per requirementWith wash, toilet & lockers

flowchart TD
    A[Diners] -->|1 m² per diner| B[Dining Hall]
    A -->|0.5 m² per diner| C[Kitchen + Service Area]
    D[Workers] --> E[Changing Rooms + Toilets + Lockers]

This ensures adequate space for diners, kitchen operations, and worker welfare per IS 6074.

14Fire Safety Measures

IS 6074 Fire Safety Measures – Key Points & Table

1. Fire Safety Objectives (Clause 22.1)

  • Minimize personal hazards (loss of life).
  • Minimize internal hazards (fire spread and damage).

2. Fire Resistance Requirements (Clause 22.8)

  • Basement fire resistance must be of the highest order.
  • Structural columns supporting upper floors must have Grade 3 or higher fire resistance.

3. Structural Components Classification (Table 7)

Grade No.Min. Fire Resistance (Hours)Fire Load (kcal/cm²)Class of Fire
16≥ 1,100,000Very High
24550,000 to 1,100,000High
32275,000 to 550,000Medium
41< 275,000Low
52-Very Low

4. Additional Notes

  • Fire resistance time refers to the minimum duration structural elements must withstand standard fire.
  • Fire load is a measure of heat energy per unit area that the structure can safely endure.
  • Lifts must comply with IS 1860:1968 for fire safety.

Summary Diagram of Fire Resistance Grading

graph LR
    A[Grade 1] -->|≥6 hrs| B[Very High Fire Load]
    C[Grade 2] -->|4 hrs| D[High Fire Load]
    E[Grade 3] -->|2 hrs| F[Medium Fire Load]
    G[Grade 4] -->|1 hr| H[Low Fire Load]
    I[Grade 5] -->|2 hrs| J[Very Low Fire Load]

Ensure structural elements are selected based on expected fire load and required fire resistance grade to comply with IS 6074 fire safety standards.

15General Hygiene and Maintenance

IS 6074: General Hygiene & Maintenance - Key Points

1. Drainage & Sanitation Fitments (Table 4, Clause 14.1.1)

FitmentResidential Public & StaffPublic RoomsNon-Residential Staff
Water-Closets1 per 8 persons (min 2 if both sexes)1 per 100 persons (up to 400), then 1 per 250Varies by persons (e.g., 1 for 1-15 persons, up to 6 for 78-100 persons)
Ablution Taps1 in each water-closet + 1 tap per 50 persons near WCs/urinalsSame as residentialSame as residential
Urinals-1 per 50 personsNil up to 6 persons
Wash Basins1 per 10 persons (excluding room suites)1 per WC and urinalSame as residential
Baths1 per 10 persons (excluding en suite)--
Slop Sinks1 per 30 bedrooms (min 1 per floor)--
Kitchen Sinks/Dishwashers1 per kitchen--

Note: Two-thirds assumed male, one-third female for calculations.


2. Ventilation Requirements (Clause 12.1, Table 2)

AreaAir Changes per Hour (ACH)
Living rooms3
Dining & lounge2-3
Big kitchen12
Small kitchen6
Toilets6

3. Exhaust Fans & Grease Filters (Clause 15.3)

  • Exhaust fans must have grease filters to collect grease, ensuring hygiene and maintenance.

Summary Diagram of Hygiene Fitments Allocation

flowchart TD
    A[Number of Persons] --> B{Type of Establishment}
    B -->|Residential| C[Water-Closets: 1/8 persons]
    B -->|Public Rooms|

Popular Questions About IS 6074

?What are the minimum sanitation and drainage requirements for hotels and restaurants under IS 6074?

IS 6074 (1971) outlines functional requirements for hotels, restaurants, and food service establishments, including sanitation and drainage. Though the code text is not detailed here, typical minimum requirements are:

Minimum Sanitation Requirements:

  • Adequate number of toilets and urinals based on occupant load.
  • Separate facilities for male, female, and staff.
  • Proper ventilation and natural lighting in toilets.
  • Availability of handwashing stations with potable water.
  • Use of non-absorbent, easy-to-clean materials for floors and walls.
  • Effective waste disposal systems to maintain hygiene.

Drainage Requirements:

  • Efficient floor drainage in kitchens, wash areas, and toilets to prevent water stagnation.
  • Separate drainage lines for wastewater and rainwater.
  • Proper slope (usually 1:100 to 1:200) for drainage pipes to ensure free flow.
  • Installation of traps and grease separators to prevent clogging and odors.
  • Compliance with local municipal drainage regulations.

Summary Table:

AspectRequirement
ToiletsAdequate number, separate by gender
VentilationNatural lighting and ventilation
MaterialsNon-absorbent, easy to clean
Drainage slope1:100 to 1:200 minimum
Waste DisposalProper traps, grease separators

For precise design, consult IS 1172 (Water Supply), IS 1742 (Sanitary Plumbing), and local municipal codes.

?How should kitchens be designed to meet hygiene and functional standards?

To design kitchens per IS 6074 for hygiene and functionality:

  • Space Requirement: Minimum 0.5 m² per diner to ensure sufficient working area (Clause 15.1). Snack bars and soda fountains include service-cum-dispensing areas as part of kitchen space.

  • Exhaust & Ventilation: Exhaust fans must have grease filters to trap grease and maintain air quality (Clause 15.3).

  • Flooring: Floors must be impervious, smooth, easily cleanable, and in good repair to maintain hygiene (Clause 7.1).

  • Sanitation Fitments: Provide adequate water-closets, wash basins, and kitchen sinks as per occupancy (refer Table 4 in Clause 14.1.1), ensuring proper drainage and sanitation.

  • General: Kitchen design should facilitate easy cleaning, prevent contamination, and support food safety protocols.

Loading diagram...

This ensures kitchens meet hygiene and functional standards per IS 6074.

?What are the fire safety provisions required for food service establishments?

Fire Safety Provisions for Food Service Establishments (IS 6074):

  1. Fire Hazard Considerations (Clause 22.1):

    • Personal Hazard: Prevent loss or damage to life.
    • Internal Hazard: Prevent fire occurrence and spread within the building.
  2. Gas Installations (Clause 23.1):

    • Must comply with local byelaws for gas cooking/heating equipment to minimize fire risk.
  3. Food Display Protection (Clause 24.2):

    • Unwrapped food/drinks on display must be protected by glass or partitions to prevent contamination and reduce fire risk from public handling.
    • Self-service counters may have openings but must intercept direct airflow from customers to food.
  4. Fire Fighting Arrangements:

    • Provide first-aid fire fighting equipment as per approved codes of practice for selection, installation, and maintenance of portable fire appliances.

Summary Diagram: Fire Safety Aspects in Food Service Establishments

Loading diagram...

Key Takeaway: Implement fire safety by addressing personal and internal hazards, ensuring safe gas installations, protecting food displays, and equipping with proper fire fighting tools.

?What medical examinations are mandated for employees handling food?

According to IS 6074, Clause 26, the mandated medical examinations for food handlers are:

  • Initial medical exam by a registered medical practitioner including:

    • Chest X-ray for tuberculosis
    • Stool examination for protozoal and helminthic parasites, and pathogens like Salmonella, Shigella, Vibrio cholerae
    • Urine examination
    • Blood tests for venereal diseases
  • Annual medical re-examination or more frequent if necessary to ensure fitness and freedom from communicable diseases.

Additional requirements include:

  • Inoculation against typhoid and paratyphoid A at appointment and every 5 years thereafter.
  • Employees must report symptoms like fever, vomiting, diarrhea, boils, cuts, or any communicable disease in themselves or family.

Hygiene practices (Clause 26.2) such as short clean fingernails and handwashing with soap before work are also mandatory.

Loading diagram...
?How does IS 6074 address contamination prevention in food display and service?

IS 6074 ensures contamination prevention in food display and service through these key provisions:

  • Food Protection: Clause 24.1 mandates all food/drink be stored/displayed protected from dust, flies, vermin, overhead leakage, sewage backflow, and unnecessary handling.

  • Display Barriers: Clause 24.2 requires unwrapped food/drinks on display to be shielded by glass or partitions to prevent public handling and contamination. Self-service counters must intercept customers' breath with glass or partitions.

  • Handling Practices: Clause 24.3 prohibits direct manual contact with sliced butter, cracked ice, and all food/drink, minimizing contamination risk.

  • Utensil Hygiene: Clause 18.3 stresses avoiding hand contact with inside surfaces of containers, utensils, tableware, and cutlery.

Together, these ensure hygienic food service by minimizing contamination vectors from environment, handling, and customer interaction.

Loading diagram...

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 6074. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required