Guide for construction of the brick kiln

IS 4805:1978 provides comprehensive guidelines for the design and construction of top-fed, coal-fired continuous brick kilns using natural draught. It covers specifications for kiln dimensions, chamber capacities, trench construction, flue and chimney design, and site selection criteria to ensure efficient brick firing and quality output. This standard is essential for engineers, manufacturers, and construction professionals involved in brick production and kiln construction in India.

14Sections
32Clauses Indexed
AI Search Ready
1978Edition
Clay and Stabilized Soil Products for ConstructionCategory
Alternative search terms: IS 4805 PDF, IS 4805 pdf free download, IS 4805 free download pdf, IS4805 PDF, IS-4805 PDF, IS 4805 1978 PDF, IS 4805:1978 PDF, IS 4805-1978 PDF, IS 4805 (1978) PDF, IS 4805 1978 edition PDF, IS 4805 edition 1978 PDF

What This Standard Covers

IS 4805:1978 provides comprehensive guidelines for the design and construction of top-fed, coal-fired continuous brick kilns using natural draught. It covers specifications for kiln dimensions, chamber capacities, trench construction, flue and chimney design, and site selection criteria to ensure efficient brick firing and quality output. This standard is essential for engineers, manufacturers, and construction professionals involved in brick production and kiln construction in India.

Who Uses This Standard

  • Civil Engineers
  • Brick Manufacturers
  • Construction Project Managers
  • Industrial Engineers
  • Architects specializing in masonry
  • Quality Control Inspectors
  • Environmental Health and Safety Officers

Key Topics Covered

Kiln capacity and chamber dimensions
Trench floor and wall construction
Flue and chimney design specifications
Site selection and sub-soil water considerations
Material recommendations for kiln walls and floors
Natural draught operation principles
Access provisions within kiln trenches
Thermal insulation techniques
Drainage and ground slope requirements
Maintenance and operational efficiency
Safety and environmental considerations
Standardized kiln shape and layout

Table of Contents

1Scope

IS 4805 - 1978 (Reaffirmed 2002): Scope Key Points

  • Chimney Shape & Attachments (Clause 4.10)

    • Must follow the shape shown in Fig. 3.
    • Two chimneys are required for the installation.
  • Flue Construction & Size (Clause 4.8)

    • Flues constructed as per Fig. 2.
    • Flue dimensions: 1.20 m × 0.90 m.
  • Material Specifications (Clause 2.5)

    • Mild Steel (MS) sheet thickness: 3 to 25 mm.
    • Base plate thickness: 25 mm or two plates of 12 mm welded.
    • Brass bush tread: 50 mm diameter.
    • Brass washer: 100 mm diameter, 12.5 mm thick.
    • Pin: 25 mm diameter, 225 mm long.

Summary Table of Key Dimensions

ComponentDimension/Thickness
Flue Size1.20 m × 0.90 m
MS Sheet Thickness3 to 25 mm
Base Plate25 mm thick or 2× 12 mm
Brass Bush Tread50 mm diameter
Brass Washer100 mm diameter, 12.5 mm thick
Pin25 mm dia, 225 mm length

If needed, refer to Fig. 2 and Fig. 3 of IS 4805 for detailed geometry and assembly.

2Necessary Information

IS 4805: Necessary Information for Top-Fed Coal Fired Continuous Brick Kilns

Key Information to be Furnished (Clause 2.1)

For efficient design and construction, provide:

  • Sub-soil water level at the kiln site
  • Ground slope and natural drainage pattern
  • Soil type, especially noting black cotton soil (expansive soil)
  • Climatic conditions (temperature, humidity, wind)
  • Proximity to inhabited areas and communication facilities

Specifications for Chimney Base Plate (Clause 2.5)

ComponentDimension/Thickness
MS Sheet Thickness3 to 25 mm
Chimney Base Plate25 mm thick or two 12 mm plates welded
Brass Bush Tread50 mm
Brass Washer Thickness12.5 mm (100 mm diameter)
Pin25 mm diameter, 225 mm long

All dimensions in centimeters unless specified.


Notes:

  • Soil and drainage data help in foundation design.
  • Climatic data influence kiln thermal performance.
  • Close proximity to habitation requires emission control.

flowchart TD
    A[Site Investigation] --> B[Sub-soil Water Level]
    A --> C[Ground Slope & Drainage]
    A --> D[Soil Type]
    A --> E[Climatic Conditions]
    A --> F[Vicinity to Habitation]
    B & C & D & E & F --> G[Design & Construction Inputs]

This ensures the kiln foundation and chimney are designed for durability and operational efficiency.

3Site Selection and Ground Conditions

IS 4805: Site Selection and Ground Conditions for Brick Kilns

Key Specifications from IS 4805:

  • Sub-soil Water Level:

    • Floor level of trenches must be ≥ 3 m above the water table during rainy season (Clause 3.2).
    • Floor level should not be more than 1 m below ground level.
  • Ground Slope & Drainage:

    • Natural slope and drainage must be assessed to avoid water accumulation (Clause 2.1b).
  • Soil Type:

    • Special attention to black cotton soil due to its expansive nature (Clause 2.1c).
  • Floor & Trench Dimensions:

    • Trench height: 2.25 m (Clause 4.2).
    • Side walls with flues for chimneys; two flues per chamber (Clause 4.3).

Checklist for Site Selection:

  • Sub-soil water level and seasonal variation
  • Ground slope and natural drainage
  • Soil type and bearing capacity
  • Climatic conditions (temperature, rainfall)
  • Proximity to inhabited areas and communication

Recommended Floor Level Criteria:

ParameterRequirement
Minimum height above water table≥ 3 m
Maximum depth below ground level≤ 1 m

Conceptual Diagram of Site Conditions:

flowchart LR
    A[Ground Level] --> B[Trench Floor Level]
    B -->|≥ 3 m above| C[Water Table (Rainy Season)]
    A -->|≤ 1 m below| B
    D[Soil Type] --> E{Black Cotton Soil?}
    E -->|Yes| F[Special Foundation Considerations]
    E -->|No| G[Standard Foundation]

Summary:
Ensure trench floors are well above the water table, assess soil type (especially black cotton soil), and verify natural drainage and slope for stable kiln construction.

4Construction

IS 4805: Guide for Construction of Brick Kiln – Key Points

Construction Specifications:

  • Flue Size:
    • Dimensions: 1.20 m x 0.90 m (Clause 4.8)
    • Flues should be constructed as per Fig. 2 (not provided here).

Important Considerations for Construction (Clause 2.1):

  • Sub-soil water level at site
  • Ground slope and natural drainage
  • Soil type, especially black cotton soil
  • Climatic conditions
  • Proximity to inhabited areas and communication facilities

General Notes:

  • The kiln is top-fed, coal-fired, and operates on natural draught.
  • Proper site evaluation is critical for structural stability and operational efficiency.

Typical Flue Section Dimensions (for reference):

ParameterDimension (m)
Flue Width1.20
Flue Height0.90

flowchart LR
    A[Site Selection] --> B[Soil & Water Table Analysis]
    B --> C[Ground Slope & Drainage]
    C --> D[Climate Considerations]
    D --> E[Kiln Construction]
    E --> F[Flue Construction (1.20 x 0.90 m)]

This ensures efficient airflow and combustion in the kiln.

4.1Kiln Size and Capacity

Kiln Size and Capacity as per IS 4805

  • Kiln Shape: Refer to Fig. 1 (Bull's Trench Kiln shape with earth embankment and enlarged section).

  • Trench Height:

    • Fixed at 2.25 m (Clause 4.2).
  • Large Capacity Kiln (Clause 4.1.1):

    • Number of chambers = 30
    • Length per chamber = 5.0 m
    • Width of trench = 9.0 m
    • Capacity per chamber = 28,000 standard bricks
  • Small Capacity Kiln (Clause 4.1.2):

    • Number of chambers = 30
    • Length per chamber = 5.0 m
    • Width of trench = 4.5 m
    • Capacity per chamber = 14,000 standard bricks
  • Flues (Clause 4.3):

    • Each chamber: 2 flues (inner & outer walls) for large capacity
    • Small capacity: 1 flue on outer wall per chamber

Summary Table

ParameterLarge Capacity KilnSmall Capacity Kiln
Chambers3030
Chamber Length (m)5.05.0
Trench Width (m)9.04.5
Trench Height (m)2.252.25
Capacity per Chamber28,000 bricks14,000 bricks
Flues per Chamber21

flowchart LR
    A[Trench Height = 2.25 m]
    B[Large Capacity Kiln]
    C[Small Capacity Kiln]
    A --> B
    A --> C
    B -->|30 Chambers| D[Each 5m length]
    B -->|Width 9m| E[Capacity 28000 bricks/chamber]
    B -->|2 flues per chamber| F[Inner & Outer walls]
    C -->|30 Chambers| G[Each 5m length]
    C -->|Width
4.2Trench Height

Key Specifications for Trench Height (IS 4805)

  • Trench Height:
    As per Clause 4.2, the trench height should be 2.25 m for both small and large capacity kilns.

  • Floor Level (Clause 3.2):

    • Minimum 3 m above the water table during rainy season.
    • Not more than 1 m below ground level.
  • Trench Floor:

    • Should be paved with burnt bricks on edge (Clause 4.5).
  • Access:

    • Provide an adequate number of wickets for easy access (Clause 4.4).

Summary Table

ParameterValue/Specification
Trench Height2.25 m
Floor Level≥ 3 m above water table; ≤ 1 m below ground level
Floor MaterialBurnt bricks on edge
AccessAdequate wickets for access

flowchart TD
    A[Ground Level] -->|Max 1 m| B[Trench Floor Level]
    B -->|Min 3 m above water table| C[Water Table]
    A --> D[Trench Height = 2.25 m]
    D --> E[Side Walls with Flues]
    B --> F[Burnt Brick Paving]
    D --> G[Wickets for Access]

This ensures structural stability, water protection, and operational convenience.

4.3Side Walls and Flues

IS 4805: Side Walls and Flues - Key Specifications

  • Side Walls:

    • Thickness: 60 cm (Clause 4.6)
    • Material: Ordinary burnt bricks recommended for durability and maintenance.
    • Construction: Two flues per chamber, one on inner and one on outer wall. For small kilns, only one flue on the outer wall per chamber is needed (Clause 4.3).
  • Flues:

    • Size: 1.20 m x 0.90 m (Clause 4.8)
    • Construction details as per Fig. 2 (not shown here) (Clause 4.8).
    • Flues support chimneys placed on side walls (Clause 4.3).
  • Height:

    • Trenches height: 2.25 m (Clause 4.2)
  • Chimneys:

    • Two chimneys required per kiln (Clause 4.10).
    • Shape and attachments as shown in Fig. 3 (not shown here).

Summary Table

ElementDimension/SpecificationClause Reference
Side wall thickness60 cm (burnt bricks preferred)4.6
Flue size1.20 m x 0.90 m4.8
Trenches height2.25 m4.2
Number of flues per chamber2 (inner + outer wall) for large; 1 for small4.3
Number of chimneys per kiln24.10

flowchart TB
    A[Side Wall (60 cm thick)] --> B[Flue (1.20 x 0.90 m)]
    B --> C[Chimney (2 per kiln)]
    A --> D[Inner Flue]
    A --> E[Outer Flue]
4.4Access Wickets

IS 4805: Access Wickets Key Points

  • Clause 4.4: Provide an adequate number of access wickets for easy entry to different trench parts.

  • Material Specs (Clause 2.5):

    • Wickets made from 3-25 mm thick MS sheet.
    • Base plate of chimney: 25 mm thick or two plates of 12 mm thick welded.
    • Brass bush tread: 50 mm diameter.
    • Brass washer: 100 mm diameter, 12.5 mm thick.
    • Pin: 25 mm diameter, 225 mm long.
    • Base plate with wheels (3B type) for mobility.
  • Dimensions:

    • All dimensions in cm unless otherwise stated.
    • Flue size (Clause 4.8): 1.20 m x 0.90 m.

Typical Access Wicket Construction Summary

ComponentDimension/ThicknessMaterial
MS Sheet3 to 25 mm thicknessMild Steel
Base Plate25 mm thick or 2x12 mmMild Steel
Brass Bush Tread50 mm diameterBrass
Brass Washer100 mm diameter, 12.5 mm thickBrass
Pin25 mm diameter, 225 mm lengthSteel

Conceptual Diagram of Access Wicket Components

graph LR
    A[MS Sheet Wicket Door] --> B[Base Plate (25 mm thick)]
    B --> C[Brass Bush Tread (50 mm)]
    C --> D[Brass Washer (100 mm x 12.5 mm)]
    D --> E[Pin (25 mm x 225 mm)]
    B --> F[Wheels (3B Base Plate)]

Summary: Ensure wickets are robust, sized for easy access, and constructed per the specified thickness and materials for durability and functionality in coal-fired brick kiln trenches.

4.5Trench Floor Paving

IS 4805: Trench Floor Paving - Key Specifications

  • Floor Paving (Clause 4.5):
    The trench floor must be paved with burnt bricks laid on edge to provide a durable, heat-resistant surface.

  • Floor Level (Clause 3.2):

    • Minimum 3 m above the water table (measured during rainy season).
    • Maximum 1 m below ground level to avoid water seepage.
  • Trench Dimensions (Clause 4.2 & 4.1.1):

    • Height: 2.25 m
    • Width: 9.0 m
    • Length per chamber: 5.0 m
    • Number of chambers (large capacity): 30
    • Capacity per chamber: 28,000 standard bricks

Typical Trench Floor Paving Detail

ParameterSpecification
Paving MaterialBurnt bricks
Brick OrientationOn edge (vertical)
Floor Level≥ 3 m above water table, ≤ 1 m below ground
Trench Height2.25 m
Trench Width9.0 m
flowchart TB
    A[Subsoil Water Table] -->|≥3 m above| B[Trench Floor (Burnt bricks on edge)]
    B --> C[Trench Walls with Flues]
    C --> D[Chimney Placement]

This ensures durability, prevents water ingress, and supports kiln operation per IS 4805.

4.6Side Wall Thickness and Materials

IS 4805 Key Specifications for Side Wall Thickness and Materials

  • Side Wall Thickness:

    • Minimum 60 cm thick (Clause 4.6).
  • Materials:

    • Constructed with ordinary burnt bricks (recommended for durability and maintenance).
    • Un-burnt bricks are permissible but less efficient.
    • Side walls plastered with mud-mortar (Clause 4.7).
  • Optional Insulation:

    • Side walls may have a 25 cm cavity filled loosely with fine ash for better insulation (Clause 4.7 Note).
  • Additional Notes:

    • Trenches height: 2.25 m (Clause 4.2).
    • Flues provided on inner and outer walls for chimney placement (Clause 4.3).

Summary Table

ParameterValue/MaterialClause Reference
Side wall thickness60 cm4.6
Brick typeOrdinary burnt bricks (preferred)4.6
PlasteringMud-mortar4.7
Insulation cavity25 cm (optional, filled with fine ash)4.7 Note
Trenches height2.25 m4.2

flowchart TD
    A[Side Wall] --> B[Thickness: 60 cm]
    A --> C[Material: Burnt Bricks]
    A --> D[Plaster: Mud Mortar]
    A --> E{Optional Cavity}
    E --> F[25 cm cavity]
    F --> G[Filled with fine ash for insulation]

This ensures structural strength, thermal efficiency, and durability of kiln side walls per IS 4805.

4.7Wall Plastering and Insulation

IS 4805: Wall Plastering & Insulation Key Points

  • Wall Thickness:

    • Side walls should be 60 cm thick using ordinary burnt bricks (clause 4.6).
    • Un-burnt bricks allowed but burnt bricks recommended for durability and efficiency.
  • Plastering:

    • Side walls must be plastered with mud-mortar (clause 4.7).
  • Insulation:

    • For better insulation, construct walls with a 25 cm cavity.
    • The cavity may be loosely filled with fine ash to improve thermal resistance.

Summary Table

ParameterSpecification
Wall thickness60 cm
Wall materialBurnt bricks (preferred)
PlasteringMud-mortar
Insulation cavity25 cm (optional)
Cavity fill materialFine ash (loose filling)

Notes:

  • The cavity with fine ash reduces heat transfer, improving kiln efficiency.
  • Mud plastering provides a breathable surface, aiding moisture control.

flowchart TD
    A[Side Wall Construction] --> B[60 cm Thick Burnt Brick Wall]
    B --> C[Plastered with Mud Mortar]
    B --> D[Cavity of 25 cm (Optional)]
    D --> E[Loose Fine Ash Filling]
    E --> F[Improved Thermal Insulation]

This approach ensures structural stability, durability, and thermal efficiency as per IS 4805 guidelines.

4.8Flue Construction Details

IS 4805: Flue Construction Details for Top-Fed Coal Fired Brick Kilns

Key Specifications:

  • Flue Size: 120 cm (length) × 90 cm (width) (Clause 4.8)
  • Distance Between Flues: 5.0 m (centre-to-centre) (Clause 4.9)
  • Number of Chimneys: Two chimneys required (Clause 4.10)
  • Shape & Attachments: As per Fig. 3 (not provided here), typically rectangular with proper draft provisions.

Construction Guidelines:

  • Flues must be constructed as per Fig. 2 (rectangular cross-section)
  • Use fire-resistant bricks and mortar
  • Ensure smooth internal surfaces to minimize resistance to gas flow

Additional Notes:

  • Flue dimensions ensure adequate natural draught for combustion
  • Centre-to-centre spacing avoids thermal interference between flues

Summary Table:

ParameterValueUnit
Flue Size (L × W)120 × 90cm
Distance Between Flues5.0m
Number of Chimneys2-

flowchart LR
    A[Flue 1] ---|5 m| B[Flue 2]
    A & B --> C[Chimneys]
    C --> D[Natural Draught]

This ensures efficient combustion and heat flow in brick kiln operation as per IS 4805.

4.9Flue Spacing

IS 4805 Key Specifications for Flue Spacing and Construction

  • Flue Size (Clause 4.8):

    • 1.20 m x 0.90 m (120 cm x 90 cm)
  • Flue Spacing (Clause 4.9):

    • 5.0 m centre-to-centre distance between flues
  • Chimney Details (Clause 4.10):

    • Two chimneys required
    • Shape and attachments as per Fig. 3 (not shown here)
  • Materials (Clause 2.5):

    • Flue sheet thickness: 3 to 25 mm MS sheet
    • Base plate: 25 mm thick or two 12 mm thick welded plates
    • Brass bush tread: 50 mm diameter
    • Brass washer: 12.5 mm thick, 100 mm diameter
    • Pin: 25 mm diameter, 225 mm long

Summary Table

ParameterSpecification
Flue Size1.20 m × 0.90 m
Flue Spacing5.0 m (centre-to-centre)
Sheet Thickness3 to 25 mm MS sheet
Base Plate Thickness25 mm or 2 × 12 mm welded
Brass Bush Diameter50 mm
Brass Washer12.5 mm thick, 100 mm dia
Pin Size25 mm dia, 225 mm long
flowchart LR
    A[Flue Size: 1.20 x 0.90 m] --> B[Spacing: 5.0 m C-C]
    B --> C[Two Chimneys Required]
    C --> D[Base Plate: 25 mm thick or 2x12 mm welded]
    D --> E[Brass Bush: 50 mm dia]
    E --> F[Brass Washer: 12.5 mm thick, 100 mm dia]
    F --> G[Pin: 25 mm dia, 225 mm long]

This ensures proper structural integrity and spacing for flue and chimney assemblies as per IS 4805.

4.10Chimney Shape and Attachments

IS 4805: Chimney Shape and Attachments - Key Points

Chimney Shape (Clause 4.10 & Fig. 3)

  • Chimneys must follow the shape shown in Fig. 3 of the code.
  • Two chimneys are required for each chamber.
  • Chimney attachments include base plates, brass bushes, washers, and pins as detailed below.

Dimensions & Specifications

  • Flue size: 1.20 m x 0.90 m (Clause 4.8, Fig. 2)
  • Height of trenches: 2.25 m (Clause 4.2)
  • Base plate thickness: 25 mm or two plates of 12 mm each (Clause 2.5)
  • MS sheet thickness: 3–25 mm (Clause 2.5)
  • Brass bush tread: 50 mm
  • Brass washer thickness: 12.5 mm, diameter 100 mm
  • Pin: 25 mm diameter, 225 mm long

Attachments Summary (Clause 2.5)

ComponentDimension/Thickness
MS Sheet3 to 25 mm
Base Plate25 mm thick or 2x12 mm
Brass Bush Tread50 mm
Brass Washer100 mm dia, 12.5 mm thick
Pin25 mm dia, 225 mm long

Flue & Chimney Arrangement (Clause 4.3)

  • Two flues per chamber: one inner wall, one outer wall.
  • Small kilns: only one outer wall flue per chamber.

flowchart TD
    A[Chimney] --> B[Base Plate (25 mm thick)]
    B --> C[Brass Bush (50 mm tread)]
    C --> D[Brass Washer (100 mm dia, 12.5 mm thick)]
    D --> E[Pin (25 mm dia, 225 mm long)]
    A --> F[Flue (1.20 m x 0.90 m)]
    F --> G[Inner Wall Flue]
    F --> H[Outer Wall Flue]

This ensures chimney stability and proper flue gas flow as per IS 4805.

Popular Questions About IS 4805

?What are the recommended dimensions for large and small capacity brick kilns?

Recommended Dimensions for Brick Kilns (IS 4805):

  • Large Capacity Kiln:

    • Number of chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 9.0 m
    • Chamber capacity: 28,000 standard bricks
    • Trench height: 2.25 m
    • Flues: Two per chamber (one inner, one outer wall)
  • Small Capacity Kiln:

    • Number of chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 4.5 m
    • Chamber capacity: 14,000 standard bricks
    • Trench height: 2.25 m
    • Flues: One per chamber (outer wall only)

These dimensions ensure efficient firing and structural stability. The kiln shape and earth embankment details are illustrated in Fig. 1 of IS 4805.

Loading diagram...
?How should the kiln site be selected considering sub-soil water and drainage?

Kiln Site Selection per IS 4805 (Clauses 2.1, 3.1 & 3.2):

  • High Ground Preference: Select a site on elevated land so rainwater naturally drains away from the kiln, preventing water logging (Clause 3.1).

  • Sub-soil Water Level:

    • Determine the sub-soil water table during the rainy season.
    • The kiln trench floor must be at least 3 m above this water table to avoid seepage and structural issues (Clause 3.2).
    • The trench floor should not be more than 1 m below ground level to maintain stability.
  • Natural Drainage & Slope: Ensure the ground slope facilitates drainage away from the kiln (Clause 2.1b).

  • Soil Type Considerations: Avoid black cotton soil or take special precautions due to its swelling nature (Clause 2.1c).


Summary Table:

ParameterRequirement
Ground ElevationHigh ground with natural drainage
Trench Floor Level≥ 3 m above sub-soil water table
Trench Floor Max Depth≤ 1 m below ground level
Soil TypeAvoid or treat black cotton soil

Loading diagram...

This ensures kiln stability, longevity, and operational efficiency.

?What materials are specified for constructing the kiln walls and floors?

According to IS 4805, the materials specified for constructing the kiln walls and floors are:

  • Side Walls:

    • Thickness: 60 cm
    • Material: Ordinary burnt bricks are recommended for better efficiency and lower maintenance.
    • Note: Unburnt bricks may be used but are less efficient.
  • Floor of Trenches:

    • No specific material mentioned, but the floor level must be above the water table (minimum 3 m above sub-soil water during rainy season) and not more than 1 m below ground level.

Summary:

PartThicknessMaterialRemarks
Side Walls60 cmBurnt bricksRecommended for durability
Trenches FloorN/ANot specifiedMust be above water table level

This ensures structural stability and kiln efficiency.

?How are the flues and chimneys designed to optimize natural draught?

Design of Flues and Chimneys for Optimizing Natural Draught (IS 4805)

  • Flue Size: As per Clause 4.8, flues are rectangular with dimensions 120 cm x 90 cm (1.20 m x 0.90 m).
  • Flue Construction: Detailed in Fig. 2 (not shown here), ensuring smooth airflow and minimal resistance.
  • Flue Spacing: Clause 4.9 mandates a 5.0 m center-to-center distance between flues to prevent airflow interference.
  • Chimney Shape and Attachments: Clause 4.10 specifies the chimney shape (Fig. 3) designed to enhance stack effect, increasing natural draught.
  • Number of Chimneys: Two chimneys are required to maintain adequate ventilation and draught.

Natural Draught Principle:

Natural draught depends on the height difference and temperature difference between flue gases and ambient air, creating pressure difference driving airflow.

[ \Delta P = C \cdot h \cdot (T_i - T_o) / T_o ]

Where:

  • (\Delta P) = draught pressure
  • (h) = chimney height
  • (T_i), (T_o) = absolute temperatures inside and outside chimney
  • (C) = constant related to air density

Summary: The IS 4805 ensures optimal natural draught by specifying flue size, spacing, chimney shape, and number, maximizing airflow efficiency in brick kilns.

?What provisions are made for access within the kiln trenches?

Access Provisions in Kiln Trenches (IS 4805)

  • Trench Height: 2.25 m (Clause 4.2)
  • Access Wickets: Adequate number of wickets must be provided for easy access to different parts of trenches (Clause 4.4).
  • Floor Level: Not less than 3 m above water table during rainy season and not more than 1 m below ground level (Clause 3.2).
  • Floor Surface: Paved with burnt bricks on edge for durability and ease of movement (Clause 4.5).

Summary:
Kiln trenches should be 2.25 m high with multiple wickets (access doors) for movement. The floor is brick-paved and elevated properly above water table to ensure stability and accessibility.

Loading diagram...