IS 4805:1978 provides comprehensive guidelines for the design and construction of top-fed, coal-fired continuous brick kilns using natural draught. It covers specifications for kiln dimensions, chamber capacities, trench construction, flue and chimney design, and site selection criteria to ensure efficient brick firing and quality output. This standard is essential for engineers, manufacturers, and construction professionals involved in brick production and kiln construction in India.
Overview
IS 4805:1978 provides comprehensive guidelines for the design and construction of top-fed, coal-fired continuous brick kilns using natural draught. It covers specifications for kiln dimensions, chamber capacities, trench construction, flue and chimney design, and site selection criteria to ensure efficient brick firing and quality output. This standard is essential for engineers, manufacturers, and construction professionals involved in brick production and kiln construction in India.
Audience
Contents
Structure
IS 4805 - 1978 (Reaffirmed 2002): Scope Key Points
Chimney Shape & Attachments (Clause 4.10)
Flue Construction & Size (Clause 4.8)
Material Specifications (Clause 2.5)
| Component | Dimension/Thickness |
|---|---|
| Flue Size | 1.20 m × 0.90 m |
| MS Sheet Thickness | 3 to 25 mm |
| Base Plate | 25 mm thick or 2× 12 mm |
| Brass Bush Tread | 50 mm diameter |
| Brass Washer | 100 mm diameter, 12.5 mm thick |
| Pin | 25 mm dia, 225 mm length |
If needed, refer to Fig. 2 and Fig. 3 of IS 4805 for detailed geometry and assembly.
IS 4805: Necessary Information for Top-Fed Coal Fired Continuous Brick Kilns
For efficient design and construction, provide:
| Component | Dimension/Thickness |
|---|---|
| MS Sheet Thickness | 3 to 25 mm |
| Chimney Base Plate | 25 mm thick or two 12 mm plates welded |
| Brass Bush Tread | 50 mm |
| Brass Washer Thickness | 12.5 mm (100 mm diameter) |
| Pin | 25 mm diameter, 225 mm long |
All dimensions in centimeters unless specified.
flowchart TD
A[Site Investigation] --> B[Sub-soil Water Level]
A --> C[Ground Slope & Drainage]
A --> D[Soil Type]
A --> E[Climatic Conditions]
A --> F[Vicinity to Habitation]
B & C & D & E & F --> G[Design & Construction Inputs]
This ensures the kiln foundation and chimney are designed for durability and operational efficiency.
IS 4805: Site Selection and Ground Conditions for Brick Kilns
Sub-soil Water Level:
Ground Slope & Drainage:
Soil Type:
Floor & Trench Dimensions:
| Parameter | Requirement |
|---|---|
| Minimum height above water table | ≥ 3 m |
| Maximum depth below ground level | ≤ 1 m |
flowchart LR
A[Ground Level] --> B[Trench Floor Level]
B -->|≥ 3 m above| C[Water Table (Rainy Season)]
A -->|≤ 1 m below| B
D[Soil Type] --> E{Black Cotton Soil?}
E -->|Yes| F[Special Foundation Considerations]
E -->|No| G[Standard Foundation]
Summary:
Ensure trench floors are well above the water table, assess soil type (especially black cotton soil), and verify natural drainage and slope for stable kiln construction.
IS 4805: Guide for Construction of Brick Kiln – Key Points
| Parameter | Dimension (m) |
|---|---|
| Flue Width | 1.20 |
| Flue Height | 0.90 |
flowchart LR
A[Site Selection] --> B[Soil & Water Table Analysis]
B --> C[Ground Slope & Drainage]
C --> D[Climate Considerations]
D --> E[Kiln Construction]
E --> F[Flue Construction (1.20 x 0.90 m)]
This ensures efficient airflow and combustion in the kiln.
Kiln Size and Capacity as per IS 4805
Kiln Shape: Refer to Fig. 1 (Bull's Trench Kiln shape with earth embankment and enlarged section).
Trench Height:
Large Capacity Kiln (Clause 4.1.1):
Small Capacity Kiln (Clause 4.1.2):
Flues (Clause 4.3):
| Parameter | Large Capacity Kiln | Small Capacity Kiln |
|---|---|---|
| Chambers | 30 | 30 |
| Chamber Length (m) | 5.0 | 5.0 |
| Trench Width (m) | 9.0 | 4.5 |
| Trench Height (m) | 2.25 | 2.25 |
| Capacity per Chamber | 28,000 bricks | 14,000 bricks |
| Flues per Chamber | 2 | 1 |
flowchart LR
A[Trench Height = 2.25 m]
B[Large Capacity Kiln]
C[Small Capacity Kiln]
A --> B
A --> C
B -->|30 Chambers| D[Each 5m length]
B -->|Width 9m| E[Capacity 28000 bricks/chamber]
B -->|2 flues per chamber| F[Inner & Outer walls]
C -->|30 Chambers| G[Each 5m length]
C -->|Width
Trench Height:
As per Clause 4.2, the trench height should be 2.25 m for both small and large capacity kilns.
Floor Level (Clause 3.2):
Trench Floor:
Access:
| Parameter | Value/Specification |
|---|---|
| Trench Height | 2.25 m |
| Floor Level | ≥ 3 m above water table; ≤ 1 m below ground level |
| Floor Material | Burnt bricks on edge |
| Access | Adequate wickets for access |
flowchart TD
A[Ground Level] -->|Max 1 m| B[Trench Floor Level]
B -->|Min 3 m above water table| C[Water Table]
A --> D[Trench Height = 2.25 m]
D --> E[Side Walls with Flues]
B --> F[Burnt Brick Paving]
D --> G[Wickets for Access]
This ensures structural stability, water protection, and operational convenience.
IS 4805: Side Walls and Flues - Key Specifications
Side Walls:
Flues:
Height:
Chimneys:
| Element | Dimension/Specification | Clause Reference |
|---|---|---|
| Side wall thickness | 60 cm (burnt bricks preferred) | 4.6 |
| Flue size | 1.20 m x 0.90 m | 4.8 |
| Trenches height | 2.25 m | 4.2 |
| Number of flues per chamber | 2 (inner + outer wall) for large; 1 for small | 4.3 |
| Number of chimneys per kiln | 2 | 4.10 |
flowchart TB
A[Side Wall (60 cm thick)] --> B[Flue (1.20 x 0.90 m)]
B --> C[Chimney (2 per kiln)]
A --> D[Inner Flue]
A --> E[Outer Flue]
IS 4805: Access Wickets Key Points
Clause 4.4: Provide an adequate number of access wickets for easy entry to different trench parts.
Material Specs (Clause 2.5):
Dimensions:
| Component | Dimension/Thickness | Material |
|---|---|---|
| MS Sheet | 3 to 25 mm thickness | Mild Steel |
| Base Plate | 25 mm thick or 2x12 mm | Mild Steel |
| Brass Bush Tread | 50 mm diameter | Brass |
| Brass Washer | 100 mm diameter, 12.5 mm thick | Brass |
| Pin | 25 mm diameter, 225 mm length | Steel |
graph LR
A[MS Sheet Wicket Door] --> B[Base Plate (25 mm thick)]
B --> C[Brass Bush Tread (50 mm)]
C --> D[Brass Washer (100 mm x 12.5 mm)]
D --> E[Pin (25 mm x 225 mm)]
B --> F[Wheels (3B Base Plate)]
Summary: Ensure wickets are robust, sized for easy access, and constructed per the specified thickness and materials for durability and functionality in coal-fired brick kiln trenches.
IS 4805: Trench Floor Paving - Key Specifications
Floor Paving (Clause 4.5):
The trench floor must be paved with burnt bricks laid on edge to provide a durable, heat-resistant surface.
Floor Level (Clause 3.2):
Trench Dimensions (Clause 4.2 & 4.1.1):
| Parameter | Specification |
|---|---|
| Paving Material | Burnt bricks |
| Brick Orientation | On edge (vertical) |
| Floor Level | ≥ 3 m above water table, ≤ 1 m below ground |
| Trench Height | 2.25 m |
| Trench Width | 9.0 m |
flowchart TB
A[Subsoil Water Table] -->|≥3 m above| B[Trench Floor (Burnt bricks on edge)]
B --> C[Trench Walls with Flues]
C --> D[Chimney Placement]
This ensures durability, prevents water ingress, and supports kiln operation per IS 4805.
IS 4805 Key Specifications for Side Wall Thickness and Materials
Side Wall Thickness:
Materials:
Optional Insulation:
Additional Notes:
| Parameter | Value/Material | Clause Reference |
|---|---|---|
| Side wall thickness | 60 cm | 4.6 |
| Brick type | Ordinary burnt bricks (preferred) | 4.6 |
| Plastering | Mud-mortar | 4.7 |
| Insulation cavity | 25 cm (optional, filled with fine ash) | 4.7 Note |
| Trenches height | 2.25 m | 4.2 |
flowchart TD
A[Side Wall] --> B[Thickness: 60 cm]
A --> C[Material: Burnt Bricks]
A --> D[Plaster: Mud Mortar]
A --> E{Optional Cavity}
E --> F[25 cm cavity]
F --> G[Filled with fine ash for insulation]
This ensures structural strength, thermal efficiency, and durability of kiln side walls per IS 4805.
IS 4805: Wall Plastering & Insulation Key Points
Wall Thickness:
Plastering:
Insulation:
| Parameter | Specification |
|---|---|
| Wall thickness | 60 cm |
| Wall material | Burnt bricks (preferred) |
| Plastering | Mud-mortar |
| Insulation cavity | 25 cm (optional) |
| Cavity fill material | Fine ash (loose filling) |
flowchart TD
A[Side Wall Construction] --> B[60 cm Thick Burnt Brick Wall]
B --> C[Plastered with Mud Mortar]
B --> D[Cavity of 25 cm (Optional)]
D --> E[Loose Fine Ash Filling]
E --> F[Improved Thermal Insulation]
This approach ensures structural stability, durability, and thermal efficiency as per IS 4805 guidelines.
IS 4805: Flue Construction Details for Top-Fed Coal Fired Brick Kilns
| Parameter | Value | Unit |
|---|---|---|
| Flue Size (L × W) | 120 × 90 | cm |
| Distance Between Flues | 5.0 | m |
| Number of Chimneys | 2 | - |
flowchart LR
A[Flue 1] ---|5 m| B[Flue 2]
A & B --> C[Chimneys]
C --> D[Natural Draught]
This ensures efficient combustion and heat flow in brick kiln operation as per IS 4805.
IS 4805 Key Specifications for Flue Spacing and Construction
Flue Size (Clause 4.8):
Flue Spacing (Clause 4.9):
Chimney Details (Clause 4.10):
Materials (Clause 2.5):
| Parameter | Specification |
|---|---|
| Flue Size | 1.20 m × 0.90 m |
| Flue Spacing | 5.0 m (centre-to-centre) |
| Sheet Thickness | 3 to 25 mm MS sheet |
| Base Plate Thickness | 25 mm or 2 × 12 mm welded |
| Brass Bush Diameter | 50 mm |
| Brass Washer | 12.5 mm thick, 100 mm dia |
| Pin Size | 25 mm dia, 225 mm long |
flowchart LR
A[Flue Size: 1.20 x 0.90 m] --> B[Spacing: 5.0 m C-C]
B --> C[Two Chimneys Required]
C --> D[Base Plate: 25 mm thick or 2x12 mm welded]
D --> E[Brass Bush: 50 mm dia]
E --> F[Brass Washer: 12.5 mm thick, 100 mm dia]
F --> G[Pin: 25 mm dia, 225 mm long]
This ensures proper structural integrity and spacing for flue and chimney assemblies as per IS 4805.
IS 4805: Chimney Shape and Attachments - Key Points
| Component | Dimension/Thickness |
|---|---|
| MS Sheet | 3 to 25 mm |
| Base Plate | 25 mm thick or 2x12 mm |
| Brass Bush Tread | 50 mm |
| Brass Washer | 100 mm dia, 12.5 mm thick |
| Pin | 25 mm dia, 225 mm long |
flowchart TD
A[Chimney] --> B[Base Plate (25 mm thick)]
B --> C[Brass Bush (50 mm tread)]
C --> D[Brass Washer (100 mm dia, 12.5 mm thick)]
D --> E[Pin (25 mm dia, 225 mm long)]
A --> F[Flue (1.20 m x 0.90 m)]
F --> G[Inner Wall Flue]
F --> H[Outer Wall Flue]
This ensures chimney stability and proper flue gas flow as per IS 4805.
Frequently Asked
Recommended Dimensions for Brick Kilns (IS 4805):
Large Capacity Kiln:
Small Capacity Kiln:
These dimensions ensure efficient firing and structural stability. The kiln shape and earth embankment details are illustrated in Fig. 1 of IS 4805.
Loading diagram...
Kiln Site Selection per IS 4805 (Clauses 2.1, 3.1 & 3.2):
High Ground Preference: Select a site on elevated land so rainwater naturally drains away from the kiln, preventing water logging (Clause 3.1).
Sub-soil Water Level:
Natural Drainage & Slope: Ensure the ground slope facilitates drainage away from the kiln (Clause 2.1b).
Soil Type Considerations: Avoid black cotton soil or take special precautions due to its swelling nature (Clause 2.1c).
| Parameter | Requirement |
|---|---|
| Ground Elevation | High ground with natural drainage |
| Trench Floor Level | ≥ 3 m above sub-soil water table |
| Trench Floor Max Depth | ≤ 1 m below ground level |
| Soil Type | Avoid or treat black cotton soil |
Loading diagram...
This ensures kiln stability, longevity, and operational efficiency.
According to IS 4805, the materials specified for constructing the kiln walls and floors are:
Side Walls:
Floor of Trenches:
| Part | Thickness | Material | Remarks |
|---|---|---|---|
| Side Walls | 60 cm | Burnt bricks | Recommended for durability |
| Trenches Floor | N/A | Not specified | Must be above water table level |
This ensures structural stability and kiln efficiency.
Design of Flues and Chimneys for Optimizing Natural Draught (IS 4805)
Natural draught depends on the height difference and temperature difference between flue gases and ambient air, creating pressure difference driving airflow.
[ \Delta P = C \cdot h \cdot (T_i - T_o) / T_o ]
Where:
Summary: The IS 4805 ensures optimal natural draught by specifying flue size, spacing, chimney shape, and number, maximizing airflow efficiency in brick kilns.
Access Provisions in Kiln Trenches (IS 4805)
Summary:
Kiln trenches should be 2.25 m high with multiple wickets (access doors) for movement. The floor is brick-paved and elevated properly above water table to ensure stability and accessibility.