IS 364:1993 specifies the requirements for fanlight catches used primarily in ventilators and fanlights in buildings. It covers materials, dimensions, manufacturing quality, finishes, marking, and sampling inspection criteria for mild steel, aluminium alloy, and cast brass fanlight catches. This standard is essential for manufacturers, suppliers, and engineers involved in the design, production, and quality assurance of fanlight hardware to ensure durability, functionality, and compliance with Indian construction practices.
Overview
IS 364:1993 specifies the requirements for fanlight catches used primarily in ventilators and fanlights in buildings. It covers materials, dimensions, manufacturing quality, finishes, marking, and sampling inspection criteria for mild steel, aluminium alloy, and cast brass fanlight catches. This standard is essential for manufacturers, suppliers, and engineers involved in the design, production, and quality assurance of fanlight hardware to ensure durability, functionality, and compliance with Indian construction practices.
Audience
Contents
Structure
IS 364 - Scope Summary
| Lot Size | Sample Size | Permissible Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
This scope ensures quality control via sampling and testing, referencing relevant material standards and rounding rules for precise compliance.
IS 364: References - Key Points
Clause 10.4: Defines criterion for conformity based on acceptance sampling.
Annex A (Clause 2.1): Lists referred Indian Standards (IS) essential for materials and methods, e.g.:
| IS No. | Title |
|---|---|
| 280:1978 | Mild steel wire for general engineering purposes |
| 292:1983 | Leaded brass ingots and castings |
| 617:1975 | Aluminium and aluminium alloys ingots and castings |
| 733:1983 | Wrought aluminium and aluminium alloy bars, rods, sections |
| 1079:1988 | Hot rolled carbon steel sheet and strip |
| 4454 (Part 1):1981 | Steel wires for cold formed springs |
| 4905:1968 | Methods for random sampling |
Rounding off rules: As per IS 2:1960, final test values must be rounded to the same significant figures as specified.
Use of Standard Mark: Governed by BIS Act 1986, ensures compliance and quality control.
| Sample Size (n) | Acceptance Number (c) |
|---|---|
| 50 | 2 |
| 100 | 5 |
| 200 | 10 |
Refer Table 1 of IS 364 for exact values.
flowchart TD
A[Sample Inspection] --> B{Defectives ≤ Acceptance Number?}
B -- Yes --> C[Lot Accepted]
B -- No --> D[Lot Rejected]
For detailed tables and exact acceptance numbers, refer to Table 1 of IS 364 and the listed IS standards in Annex A.
IS 364 – Fanlight Catches: Key Specifications & Dimensions
| Dimension (mm) | Tolerance (mm) |
|---|---|
| Up to and including 5 | ± 0.2 |
| Above 5 up to 25 | ± 0.5 |
| Above 25 | ± 1 |
graph LR
A[Fanlight Catch Types] --> B[Mild Steel (Stove Enamelled)]
A --> C[Aluminium Alloy]
A --> D[Cast Brass]
E[Design] --> F[14 mm size]
E --> G[6 coils, 12 mm ID, 20 mm length]
E --> H[CSK hole & Wood screw No.8]
I[Quality Checks] --> J[Dimensions]
I --> K[Manufacturing Defects]
I --> L[Finish]
This summarizes the key IS 364 clauses for fanlight catches.
Materials Reference Standards:
| Lot Size | Sample Size | Permissible Defectives (Acceptance Number) |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1000 | 50 | 3 |
| 1001 and above | 80 | 5 |
flowchart TD
A[Lot Size] --> B{Select Sample Size}
B -->|Up to 100| C[Sample 13]
B -->|101-300| D[Sample 20]
B -->|301-500| E[Sample 32]
B -->|501-1000| F[Sample 50]
B -->|1001+| G[Sample 80]
C --> H{Defectives ≤ 0?}
D --> I{Defectives ≤ 1?}
E --> J{Defectives ≤ 2?}
F --> K{Defectives ≤ 3?}
G --> L{Defectives ≤ 5?}
H -->|Yes| M[Accept Lot]
IS 364: Dimensions and Tolerances for Fanlight Catch
| Dimension (mm) | Tolerance (mm) |
|---|---|
| Up to and including 5 | ± 0.2 |
| Above 5 and up to 25 | ± 0.5 |
| Above 25 | ± 1.0 |
| Lot Size | Sample Size | Permissible Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| Above 1,000 | 80 | 5 |
flowchart TD
A[Lot Size] --> B[Select Sample Size]
B --> C{Count Defectives}
C -->|≤ Permissible| D[Lot Conforms]
C -->|> Permissible| E[Lot Does Not Conform]
This summary ensures compliance with IS 364 dimensional and quality standards for fanlight catches.
Clause 10.2 & 10.4: Sampling & Acceptance Criteria
| Lot Size | Sample Size | Permissible Number of Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
Rounding Off Results:
Referenced Material Standards:
flowchart TD
A[Start: Lot of Fanlight Catches] --> B{Determine Lot Size}
B --> |Up to 100| C[Sample 13 units]
B --> |101 to 300| D[Sample 20 units]
B --> |301 to 500| E[Sample 32 units]
B --> |501 to 1000| F[Sample 50 units]
B --> |1001 and above| G[Sample 80 units]
C & D & E & F & G --> H[Inspect Sample for Defects]
H --> I{Defectives ≤ Permissible Number?}
I --> |Yes| J[Lot Accepted]
I --> |No| K[Lot Rejected]
This ensures quality control by statistically verifying workmanship and manufacturing conformity per IS 364.
Finish Specifications:
| Lot Size | Sample Size | Permissible Number of Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
flowchart LR
A[Lot of Fanlight Catches] --> B[Sample Selection per Table 1]
B --> C{Defectives ≤ Permissible?}
C -- Yes --> D[Lot Accepted]
C -- No --> E[Lot Rejected]
This ensures finish quality and conformity in production.
Marking Clause (8.1.1):
| Lot Size | Sample Size | Permissible Number of Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
flowchart LR
A[Lot Size] --> B[Sample Size]
B --> C[Check Defectives]
C -->|Defectives ≤ Permissible| D[Lot Accepted]
C -->|Defectives > Permissible| E[Lot Rejected]
D --> F[Mark with BIS Standard Mark]
This summarizes marking and acceptance criteria per IS 364 for fanlight catches.
IS 364: Packing and Labelling Key Points
| Lot Size | Sample Size | Permissible Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
flowchart TD
A[Fanlight Catches] --> B{Material Type}
B -->|Mild Steel/Brass| C[Wrap in Paper]
B -->|Aluminium Alloy| D[Wrap in Tissue/Polythene]
C --> E[Pack in Cartons]
D --> E
E --> F[Label: Manufacturer, Type, Quantity]
This ensures protection, identification, and quality control per IS 364.
IS 364 - Sampling and Criteria for Acceptance
| Lot Size | Sample Size | Permissible Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
flowchart TD
A[Lot Size] --> B{Select Sample Size}
B -->|Up to 100| C[Sample = 13, Max Defectives = 0]
B -->|101-300| D[Sample = 20, Max Defectives = 1]
B -->|301-500| E[Sample = 32, Max Defectives = 2]
B -->|501-1000| F[Sample = 50, Max Defectives = 3]
B -->|>1000| G[Sample = 80, Max Defectives = 5]
C & D & E & F & G --> H{Count Defectives}
H -->|≤ Max| I[Accept Lot]
H -->|> Max| J[Reject Lot]
Summary: Use Table 1 for sample size and acceptance number, select randomly, and accept/reject lot based on defectives count.
IS 364 - List of Referenced Indian Standards (Annex A)
This standard references essential Indian Standards related to materials used in engineering and construction. Key referenced IS codes include:
| IS No. | Title |
|---|---|
| IS 280:1978 | Mild steel wire for general engineering purposes (3rd revision) |
| IS 292:1983 | Leaded brass ingots and castings (2nd revision) |
| IS 617:1975 | Aluminium and aluminium alloys ingots and castings (2nd revision) |
| IS 733:1983 | Wrought aluminium and aluminium alloy bars, rods, and sections (3rd revision) |
| IS 739:1992 | Wrought aluminium and aluminium alloy wire for general engineering purposes (3rd revision) |
| IS 1079:1988 | Hot rolled carbon steel sheet and strip (4th revision) |
| IS 4454 (Part 1):1981 | Steel wires for cold formed springs: Part 1 - Patented and cold drawn steel wires - unalloyed (2nd revision) |
| IS 4905:1968 | Methods for random sampling |
graph LR
A[IS 364] --> B[IS 280: Mild Steel Wire]
A --> C[IS 292: Leaded Brass]
A --> D[IS 617: Aluminium Ingots]
A --> E[IS 733: Aluminium Bars & Rods]
A --> F[IS 739: Aluminium Wire]
A --> G[IS 1079: Hot Rolled Steel Sheets]
A --> H[IS 4454: Steel Wires for Springs]
A --> I[IS 4905: Sampling Methods]
For detailed material properties and testing, consult each referenced IS document directly.
The Builders Hardware Sectional Committee, CED 15 is responsible for preparing the standard. Key members include:
Member Secretary: Hemant Kumar, Joint Director (Civil Engg), BIS
| Role | Representative Organization | Name(s) |
|---|---|---|
| Chairman | CPWD, New Delhi | Shri P. Krishnan |
| Members | Various Govt. & Industry Bodies | Multiple (see Annex B) |
| Member Secretary | BIS | Hemant Kumar |
If you need detailed acceptance criteria or sampling tables, refer to Clause 10.4 and Table 1 of IS 364.
Frequently Asked
Materials for Fanlight Catches as per IS 364:
| Material | IS Code Reference | Specification Detail |
|---|---|---|
| Cast Brass | IS 292:1983 (LCB-2) | Cast brass grade LCB-2 |
| Aluminium Alloy | IS 617:1975 (5230-M) | Aluminium alloy designation |
| Mild Steel | Not specifically detailed | General mild steel |
This ensures durability and compatibility for fanlight catches in building hardware.
According to IS 364, Clause 5.1, the dimensional tolerances for fanlight catches are as follows:
| Dimension (mm) | Tolerance (± mm) |
|---|---|
| Up to and including 5 | 0.2 |
| Above 5 and up to including 25 | 0.5 |
| Above 25 | 1.0 |
This ensures proper fit and function in ventilator installations.
Evaluation of Quality and Workmanship of Fanlight Catches as per IS 364
Dimensional Check (Clause 10.2 & 5):
Manufacturing Defects (Clause 6.1 & 10.2):
Finish (Clause 7 & 10.2):
Packaging (Clause 9.1):
If any characteristic fails, the fanlight catch is deemed defective.
Loading diagram...
Recommended Finishes for Fanlight Catches (IS 364):
Aluminium Alloy Fanlight Catches (Clause 7.1):
Brass Fanlight Catches (Clause 7.2):
Summary Table:
| Material | Finish Type | Coating Thickness | Notes |
|---|---|---|---|
| Aluminium Alloy | Anodized | ≥ 0.015 mm (normal) <br> ≥ 0.025 mm (exterior) | Light fast colors for exterior |
| Brass | Satin or as specified | N/A | As per purchaser’s choice |
This ensures durability, corrosion resistance, and aesthetic quality suitable for the intended environment.
Sampling and Acceptance Criteria for Fanlight Catches (IS 364 - Clause 10.2 & Table 1):
| Lot Size | Sample Size | Permissible Defectives |
|---|---|---|
| Up to 100 | 13 | 0 |
| 101 to 300 | 20 | 1 |
| 301 to 500 | 32 | 2 |
| 501 to 1,000 | 50 | 3 |
| 1,001 and above | 80 | 5 |
If defects exceed permissible limits, the lot is rejected.
Dimensional Tolerances (Clause 5.1):
| Dimension (mm) | Tolerance (mm) |
|---|---|
| Up to and including 5 | ± 0.2 |
| Above 5 up to 25 | ± 0.5 |
| Above 25 | ± 1 |
This ensures quality control by statistically sampling and setting strict defect limits per lot size.
Ask AI about any clause, requirement, or provision in IS 364. Get instant, clause-cited responses powered by our indexed library.