IS 29301980AI Search Enabled✦ AI Generated

Functional requirements for hose laying tender for fire brigade use

IS 2930:1980 specifies the functional requirements for hose laying tenders used by fire brigades to rapidly deploy long hose lines for firefighting. It covers design, construction, performance, and equipment standards to ensure reliability, safety, and operational efficiency of these specialized vehicles. This standard is essential for manufacturers, purchasers, and users involved in fire service vehicle procurement and maintenance.

9Sections
141Clauses Indexed
AI Search Ready
1980Edition
Fire FightingCategory
Alternative search terms: IS 2930 PDF, IS 2930 pdf free download, IS 2930 free download pdf, IS2930 PDF, IS-2930 PDF, IS 2930 1980 PDF, IS 2930:1980 PDF, IS 2930-1980 PDF, IS 2930 (1980) PDF, IS 2930 1980 edition PDF, IS 2930 edition 1980 PDF

What This Standard Covers

IS 2930:1980 specifies the functional requirements for hose laying tenders used by fire brigades to rapidly deploy long hose lines for firefighting. It covers design, construction, performance, and equipment standards to ensure reliability, safety, and operational efficiency of these specialized vehicles. This standard is essential for manufacturers, purchasers, and users involved in fire service vehicle procurement and maintenance.

Who Uses This Standard

  • Fire brigade vehicle manufacturers
  • Fire service procurement officers
  • Fire safety engineers
  • Municipal fire department managers
  • Vehicle maintenance supervisors
  • Firefighting equipment suppliers
  • Civil engineering consultants specializing in fire safety

Key Topics Covered

Chassis design and load capacity
Engine performance and starting systems
Brake system specifications
Electrical system requirements
Driver and crew compartment design
Hose compartment features and lighting
Vehicle stability and dimensions
Safety features including doors and locking
Ventilation and environmental controls
Accessory equipment and tools
Communication systems between crew and driver
Materials and corrosion resistance
Instruction and maintenance documentation

Table of Contents

1Scope

IS 2930: Scope & Key Specifications Summary

This standard covers the functional requirements for hose laying tenders used by fire brigades to lay long hose lines for firefighting.

Key Specifications (Clause 6.3 - Appendix A)

Item No.DescriptionQuantity
1Hose, delivery 70 mm, rubber lined (IS:636)75 Numbers
2Hose clamps (IS:5612 Part I)24 Numbers
3Hose bandages (IS:5612 Part II)24 Numbers
4Hose ramps (wooden or sand filled)12 pairs
5Electric torches4 Numbers
6Folding canvas cams, 4500 litres capacity2 Numbers

Additional Accessories (Clause 6.2)

  • Fire bells (250 mm diameter)
  • Head lamps (≥20 cm diameter), fog lamps, reversing light
  • Twin amber blinkers, trafficators with indicator lights
  • Wind screen wipers and defrosting devices
  • Tools for routine maintenance
  • Search light with tripod and ≥30 m TRS cable (≤2% voltage drop)
  • Spot light and inspection lamp with plug socket
  • Three electric swiveling fans powered by vehicle battery

Units & Definitions (SI Units)

QuantityUnitSymbolDefinition
ForcenewtonN1 N = 1 kg·m/s²
Pressure, stresspascalPa1 Pa = 1 N/m²
EnergyjouleJ1 J = 1 N·m
PowerwattW1 W = 1 J/s
FrequencyhertzHz1 Hz = 1 cycle/s

This standard ensures equipment compatibility, performance, and safety for fire brigade hose laying tenders.

flowchart LR
    A[Hose Laying Tender] --> B[Hose Delivery 70mm]
    A --> C[Hose Clamps &
2References

IS 2930 - Key References, Formulas & Specifications

1. Equipment Schedule (Appendix A, Clause 6.3)

Item No.DescriptionQuantity
1Hose, delivery 70 mm, rubber lined (IS:636-1979 Type II)75 Nos (30 m each)
2Hose Clamps (IS:5612 Part I-1977)24 Nos
3Hose Bandages (IS:5612 Part II-1977)24 Nos
4Hose Ramps (wooden or sand filled)12 pairs
5Electric Torches4 Nos
6Folding Canvas Cams (4,500 litres capacity)2 Nos

2. Accessories (Clause 6.2)

  • Fire bell: 250 mm diameter, natural tone, operable from inside cab.
  • Headlamps: Two, ≥ 20 cm diameter.
  • Fog lamps, reversing light, twin amber blinkers.
  • Trafficators with illuminated indicators.
  • Defrosting device, windscreen wipers.
  • Tools for routine maintenance.
  • Trailer tail light connection (twin-wire socket/plug).
  • Search light with tripod and ≥30 m TRS cable (≤2% voltage drop).
  • Spot light, inspection lamp, electric swiveling fans (3 Nos).

3. SI Units & Definitions (Clause on Units)

QuantityUnitSymbolDefinition
ForcenewtonN1 N = 1 kg·m/s²
EnergyjouleJ1 J = 1 N·m
PowerwattW1 W = 1 J/s
Pressure/StresspascalPa1 Pa = 1 N/m²

4. Notes

  • Hose specification per IS:636-1979 (rubber lined, woven-jacketed).
  • Hose clamps and bandages per IS:5612 (Parts I & II).
  • Fire bell per IS (revised).
  • Voltage drop in searchlight cable ≤ 2%.

flowchart TB
    A[Hose Laying Tender] --> B[Hose Delivery 70 mm]
   
3Materials and Corrosion Resistance

IS 2930: Materials and Corrosion Resistance Key Points

  • Clause 3.1.1: All parts in contact with water must be made of corrosion-resistant materials or treated for corrosion resistance.
  • Clause 3.1: Materials used shall be mild steel or aluminium.

Corrosion Resistance Measures:

  • Use corrosion-resistant alloys or coatings (e.g., galvanizing mild steel).
  • Protective paints or treatments on mild steel.
  • Aluminium naturally resists corrosion but may require anodizing for enhanced durability.

Relevant Specifications for Components (Clause 6.3, Appendix A):

ItemSpecification ReferenceQuantity
Hose, delivery 70mmIS: 636-1979 (Rubber lined, Type II)75 Numbers (30m)
Hose ClampsIS: 5612 (Part I) - 197724 Numbers
Hose BandagesIS: 5612 (Part II) - 197724 Numbers

Notes:

  • Use rubber-lined hoses (IS 636) for durability and corrosion resistance.
  • Hose clamps and bandages per IS 5612 ensure secure, corrosion-resistant joints.

Summary Table: Material Selection for Water-Contact Parts

MaterialCorrosion ResistanceTreatment Required
Mild SteelModerateGalvanizing / Paint Coating
AluminiumGood (natural oxide layer)Optional anodizing

flowchart TD
    A[Water Contact Parts] --> B{Material}
    B --> C[Mild Steel]
    B --> D[Aluminium]
    C --> E[Apply corrosion protection]
    D --> F[Usually corrosion resistant]
    E --> G[Galvanize / Paint]
    F --> H[Optional anodizing]

Use IS 636 and IS 5612 for hoses and accessories to ensure compliance and corrosion resistance.

4Design and Construction

IS 2930: Design and Construction Key Points

  • Material Specifications (Clause 3.1.1):
    All parts in contact with water must be corrosion-resistant or treated for corrosion resistance.

  • Roof Construction (Clause 4.5.1.7):
    Roof must support the weight of one man without damage.

  • Equipment Schedule (Appendix A, Clause 6.3):

    ItemDescriptionQuantity
    1Delivery Hose, 70 mm, rubber lined (IS 636-1979)75 Nos (30 m each)
    2Hose Clamps (IS 5612 Part I-1977)24 Nos
    3Hose Bandages (IS 5612 Part II-1977)24 Nos
    4Hose Ramps (wooden/sand filled)12 pairs
    5Electric Torches4 Nos
    6Folding Canvas Cams (4,500 litres capacity each)2 Nos
  • Units & Symbols (SI Units):

    • Length: metre (m)
    • Force: newton (N = 1 kg·m/s²)
    • Pressure/Stress: pascal (Pa = 1 N/m²)
    • Power: watt (W = 1 J/s)
    • Frequency: hertz (Hz = 1 cycle/s)

Summary Diagram: Design Requirements

graph TD
A[Design & Construction] --> B[Corrosion Resistance]
A --> C[Roof Strength]
A --> D[Equipment Provision]
B --> E[Material or Treatment]
C --> F[Support 1 Man Weight]
D --> G[Hose, Clamps, Bandages, Ramps, Torches, Canvas]

This ensures durability, safety, and operational readiness per IS 2930.

5Workmanship and Finish

IS 2930: Workmanship and Finish Key Points

  • Workmanship (Clause 5.1):
    All parts of the appliance must exhibit good workmanship, ensuring durability and proper functioning.

  • Corrosion Resistance (Clause 3.1.1):
    Parts in contact with water or forming water-ways must be corrosion-resistant or suitably treated.

  • Stability (Clause 4.8):
    Appliance must not overturn when tilted up to 25° under fully equipped and loaded conditions (excluding crew).

  • Schedule of Equipment (Appendix A, Clause 6.3):
    Key equipment includes:

    ItemDescriptionQuantity
    1Hose, delivery 70 mm, rubber lined (IS 636-1979)75 Nos
    2Hose clamps (IS 5612 Part I-1977)24 Nos
    3Bandages (IS 5612 Part II-1977)24 Nos
    4Hose ramps (wooden/sand filled)12 pairs
    5Electric torches4 Nos
    6Folding canvas cams (4,500 L capacity)2 Nos

Summary Table of Key Specifications

ParameterSpecification
Stability Tilt Angle≤ 25° overturning angle
Hose Diameter70 mm rubber-lined (IS 636)
Hose Length30 m per hose
Hose Clamps & BandagesAs per IS 5612 Parts I & II
Corrosion ResistanceMandatory for water-contact parts

Practical Notes

  • Use corrosion-resistant materials (e.g., stainless steel, brass) or protective coatings for water-contact parts.
  • Ensure all fittings and hoses comply with referenced IS standards for safety and reliability.
  • Maintain high-quality finish to prevent premature wear and corrosion.
graph LR
A[Good Workmanship] --> B[Corrosion Resistance]
B --> C[Durability]
A --> D[Proper Functioning]
D --> E[Safety & Stability]
E --> F[Max Tilt 25°]

This ensures appliance reliability and safety per IS 2930 requirements.

6Accessories and Equipment

IS 2930 - Accessories & Equipment Key Points

Clause 6.2: Accessories Specifications

  • Fire Bell: 250 mm diameter, natural tone carillon, externally mounted, operable from driver's compartment.
  • Head Lamps: 2 lamps, ≥ 20 cm diameter.
  • Fog Lamps: Low mounted.
  • Reversing Light: Positioned to assist reversing.
  • Twin Amber Blinker Lights: On top of driving compartment.
  • Trafficators: Illuminated indicators visible from driver's panel.
  • De-frosting Device & Wind Screen Wipers: For clear visibility.
  • Tools: Full set for routine maintenance excluding chassis kit.
  • Trailer Tail Light Connection: Twin-wire socket/plug, minimal voltage drop (≤ 2%).
  • Search Light: Adjustable flood/beam, detachable with tripod, ≥ 30 m TRS cable.
  • Spot Light: Adjustable, near side of driving compartment.
  • Inspection Lamp: Protected, plug-in on control panel.
  • Electric Fans: 3 swiveling fans powered by vehicle battery (1 driver, 2 rear cabin).

Clause 6.3: Equipment Schedule (Appendix A)

Item No.DescriptionQuantity
1Hose, delivery 70 mm, rubber lined (IS:636-1979)75 Nos
2Hose Clamps (IS:5612 Part I)24 Nos
3Hose Bandages (IS:5612 Part II)24 Nos
4Hose Ramps (wooden or sand filled)12 pairs
5Electric Torches4 Nos
6Folding Canvas Cams (4,500 litres)2 Nos

Important Notes:

  • Hose, clamps, and bandages conform to relevant IS standards.
  • Electrical accessories must ensure minimal voltage drop (≤ 2%) in cables.
  • Colours and paints conform to IS specifications for ready-mixed paints.

Summary Diagram: Accessories Layout on Vehicle

graph LR
A[Driver's Compartment] -->|Fire Bell| B[Exterior Mount]
A -->|Head Lamps| C
7Testing and Performance Requirements

IS 2930: Testing and Performance Requirements - Key Points

Equipment Schedule (Appendix A, Clause 6.3)

Item No.DescriptionQuantity
1Hose, delivery 70 mm, rubber lined (IS 636-1979 Type II)75 Nos (30 m each)
2Hose clamps (IS 5612 Part I - 1977)24 Nos
3Hose bandages (IS 5612 Part II - 1977)24 Nos
4Hose ramps (wooden or sand filled)12 pairs
5Electric torches4 Nos
6Folding canvas (4,500 litres capacity)2 Nos

Performance & Testing Notes

  • Hose and accessories must conform to referenced IS specifications for durability and performance.
  • Hose length and diameter are critical for flow rate and pressure calculations.
  • Rounding off of test results must comply with IS 2-1960.
  • Units and measurements follow SI units (e.g., pressure in Pascal, force in Newton).

Important SI Units for Testing

QuantityUnitSymbol
Lengthmetrem
ForcenewtonN (1 N = 1 kg·m/s²)
PressurepascalPa (1 Pa = 1 N/m²)
PowerwattW (1 W = 1 J/s)

Typical Fire Hose Flow Formula

[ Q = A \times v = \frac{\pi d^2}{4} \times v ]

  • (Q): Flow rate (m³/s)
  • (A): Cross-sectional area (m²)
  • (d): Hose diameter (m)
  • (v): Velocity of water (m/s)

flowchart LR
    A[Water Source] --> B[Hose Laying Tender]
    B --> C[70 mm Rubber-lined Hose]
    C --> D[Fire Site]
    D --> E[Fire Fighting]

This standard ensures hose laying tenders are equipped and tested for reliable fire fighting over long distances.

8Instruction Book and Maintenance

IS 2930 - Instruction Book & Maintenance Key Points

1. Instruction Book (Clause 6.1)

  • Must include operating and normal maintenance procedures.
  • Should have an itemized, illustrated spare parts list with reference numbers for all wearing parts.

2. Accessories & Equipment (Clause 6.2)

  • Fire bell (250 mm diameter), externally mounted, operable from inside.
  • Head lamps (≥20 cm diameter), fog lamps, reversing light.
  • Twin amber blinker lights, trafficators with illuminated indicators.
  • Defrosting device, windscreen wipers.
  • Tools for routine maintenance (beyond chassis kit).
  • Trailer tail light connection (twin-wire socket/plug).
  • Search light with tripod and ≥30 m TRS cable (≤2% voltage drop).
  • Spot light, inspection lamp with plug socket.
  • Three electric swiveling fans powered by vehicle battery.

3. Schedule of Equipment (Appendix A, Clause 6.3)

Item No.DescriptionQuantity
1Hose, delivery 70 mm, rubber lined (IS:636)75 numbers
2Hose clamps (IS:5612 Part I)24 numbers
3Bandages (IS:5612 Part II)24 numbers
4Hose ramps (wooden or sand filled)12 pairs
5Electric torches4 numbers
6Folding canvas cams (4,500 litres capacity)2 numbers

4. Paint Specification (Clause 5.2)

  • Fire red color, Shade No. 536 as per IS:5-1978.
  • Paint conforms to IS:2932-1974.

Summary Diagram: Instruction Book & Maintenance Flow

flowchart TD
    A[Instruction Book] --> B[Operating Procedures]
    A --> C[Maintenance Procedures]
    A --> D[Spare Parts List]
    E[Accessories & Equipment] --> F[Fire Bell, Lamps, Fans]
    E --> G[Tools & Connections]
    H[Schedule of Equipment] --> I[Hoses, Clamps, Bandages]
    H --> J[
Appendix AList of Equipment to be Provided

IS 2930 - List of Equipment to be Provided (Clause 6.3 & Appendix A)

Item No.DescriptionQuantity
1.Hose, delivery 70 mm, rubber lined as per Type II of IS:636-1979, 30 m length75 Nos
2.Hose Clamps (IS:5612 Part I - 1977)24 Nos
3.Hose Bandages (IS:5612 Part II - 1977)24 Nos
4.Hose Ramps (wooden or sand-filled)12 pairs
5.Electric Torches4 Nos
6.Folding Canvas Cams, each 4500 litres capacity2 Nos

Additional Electrical Equipment (Clause 6.2):

  • Fire Bell (250 mm diameter, natural tone)
  • Head Lamps (2 nos, ≥ 20 cm diameter)
  • Fog Lamps (low mounted)
  • Reversing Light
  • Twin Amber Blinker Lights
  • Trafficators with indicator lights
  • Defrosting device & Wind Screen Wipers
  • Tools for routine maintenance
  • Tail Light connection socket (twin-wire)
  • Search Light with tripod & ≥ 30 m TRS cable (max 2% voltage drop)
  • Spot Light (adjustable)
  • Inspection Lamp (protected type, plug-in)
  • Three electric swiveling fans (1 driver cabin, 2 rear cabin)

Notes:

  • Hose as per IS:636-1979 (fire fighting hose, rubber lined woven-jacketed).
  • Clamps & Bandages as per IS:5612.
  • Electrical equipment ensures operational safety and visibility.

flowchart TD
    A[Fire Appliance] --> B[Hoses & Clamps]
    A --> C[Electrical Equipment]
    B --> B1[Hose Delivery 70mm]
    B --> B2[Hose Clamps & Bandages]
    C --> C1[Fire Bell]
    C --> C2[Head & Fog Lamps]
    C --> C3[Search & Spot Lights]
    C --> C4[Fans & Inspection Lamp]

This summary ensures compliance with IS 2930 equipment specifications for fire appliances.

Popular Questions About IS 2930

?What are the minimum engine power requirements for a hose laying tender under IS 2930?

IS 2930 (1980) specifies functional requirements for hose laying tenders but does not explicitly state minimum engine power requirements.

General engineering practice for hose laying tenders (fire brigade vehicles) suggests:

  • Minimum engine power typically ranges from 70 to 100 HP to ensure adequate mobility and operation under load.
  • Power must be sufficient to drive the vehicle fully loaded with equipment, hose reels, and water tanks.
  • Engine power should support rapid acceleration and maintain speed on gradients (usually up to 15%).

Recommended considerations:

  • Vehicle weight (laden)
  • Terrain and operational conditions
  • Pump and auxiliary equipment power needs

For precise power ratings, consult vehicle manufacturer specs or relevant vehicle design standards.

Loading diagram...

Summary: IS 2930 focuses on functional requirements; engine power is guided by operational needs, typically 70-100 HP.

?How does the standard specify the brake performance for fire brigade hose laying tenders?

IS 2930 specifies brake performance for fire brigade hose laying tenders under its functional and performance requirements section, focusing on safety and operational reliability.

Brake Performance Requirements (Summary):

  • The tender must have a reliable braking system capable of stopping the vehicle safely under loaded and unloaded conditions.
  • Brakes should be tested to ensure adequate stopping distance on both dry and wet surfaces.
  • The system should include service brakes and an emergency/parking brake that can hold the vehicle stationary on a slope.
  • Brake components must be durable and resistant to wear, ensuring consistent performance during firefighting operations.

Typical Performance Criteria (based on general engineering practice):

ParameterRequirement
Stopping distanceAs per vehicle speed and load
Brake force distributionBalanced between axles
Emergency brake holdingVehicle must hold on a slope (e.g., 15%)

Loading diagram...

For exact values, refer to detailed test procedures in IS 2930 or related automotive brake standards.

?What safety features are mandated for the driver and crew compartments?

Safety Features for Driver and Crew Compartments as per IS 2930:

  • Maximum Vision: Driving compartment designed for maximum driver visibility (Clause 4.5.2).
  • Driver's Seat: Adjustable, preferably bucket type for ergonomic safety (Clause 4.5.2).
  • Doors:
    • Doors on both sides for ready access.
    • Hinged, opening outward.
    • Door locks prevent inadvertent opening from inside.
    • Toughened glass winding windows with mechanical regulators (Clause 4.5.2).
  • Lighting:
    • Minimum one light in driver’s cabin, three at rear cabin roof level.
    • Separate switches.
    • Driver's cabin light switches ON/OFF with door opening (Clause 4.5.1.5).
  • Partition:
    • Full partition between driver and rear body.
    • Made of 1.6 mm mild steel with 1.2 mm aluminium panelling.
    • Sliding glass window approx. 500 x 350 mm (Clause 4.5.2.1).
  • Enclosed Accommodation: For officer and driver in front, with partition forming hose-carrying body and space for two men behind (Clause 4.5.1.1).

These features ensure safety, accessibility, visibility, and protection for driver and crew.

?Which materials are recommended for parts in contact with water to prevent corrosion?

According to IS 2930:

  • Clause 3.1.1: All parts in contact with water must be corrosion-resistant or treated for corrosion resistance.
  • Clause 3.1: Materials used are mild steel or aluminium.
  • For water-contact parts, aluminium is preferred due to its natural corrosion resistance.
  • Mild steel parts should be properly treated (e.g., galvanizing, painting) to prevent rust.
  • Drainholes (Clause 4.5.1.2) ensure water does not accumulate, reducing corrosion risk.

Recommended materials for water-contact parts:

  • Aluminium sheets (naturally corrosion-resistant)
  • Mild steel with corrosion protection (galvanized or painted)

Summary:

MaterialCorrosion ResistanceTreatment Required
AluminiumHighNone or minimal
Mild SteelLowGalvanizing/painting/etc.
Loading diagram...

Use aluminium where possible; otherwise, protect mild steel adequately.

?What accessories and communication systems must be included on the hose laying tender?

According to IS 2930, a hose laying tender must include the following accessories and communication systems:

Accessories (Clause 6.2)

  • Fire Bell: 250 mm diameter, natural tone, externally mounted, operable from inside the cab.
  • Head Lamps: Two, minimum 20 cm diameter.
  • Fog Lamps: Low-mounted.
  • Reversing Light: Positioned to assist reversing.
  • Twin Amber Blinker Lights: On top of driving compartment.
  • Trafficators: Illuminated indicators visible on instrument panel.
  • Defrosting Device for windscreen.
  • Windscreen Wipers.
  • Tools: For routine maintenance (excluding chassis kit).
  • Trailer Tail Light Connection: Twin-wire socket and plug.
  • Search Light: Adjustable flood/beam, tripod-mounted, with ≥30 m TRS cable (max 2% voltage drop).
  • Spot Light: Adjustable, near side of driving compartment.
  • Inspection Lamp: Protected type, plug socket on control panel.
  • Electric Fans: Three swiveling fans (1 in driver cabin, 2 in rear cabin).

Communication System (Clause 4.5.3.1)

  • Internal Electric Lighting in hose compartment.
  • Signalling System: Bell-push at rear gangway + bell in driver’s cab for communication between hose supervisor and driver.
Loading diagram...

This ensures effective communication during hose deployment.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 2930. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required