IS 2556 Part 22004AI Search Enabled✦ AI Generated

Vitreous Sanitary Appliances (Vitreous China) - - Part 2: Specific Requirements of Washdown Water Closets

IS 2556 Part 2: 2004 specifies the detailed requirements for washdown water closets made of vitreous china, focusing on design, dimensions, performance, and testing to ensure sanitary efficiency and durability. This standard applies to manufacturers, designers, and quality inspectors involved in producing and evaluating pedestal water closets with various trap patterns used in residential and commercial sanitation systems in India.

10Sections
69Clauses Indexed
AI Search Ready
2004Edition
Sanitary Appliances and Water FittingsCategory
Alternative search terms: IS 2556 Part 2 PDF, IS 2556 Part 2 pdf free download, IS 2556 Part 2 free download pdf, IS2556Part2 PDF, IS-2556-Part-2 PDF, IS 2556 Part 2 2004 PDF, IS 2556 Part 2:2004 PDF, IS 2556 Part 2-2004 PDF, IS 2556 Part 2 (2004) PDF, IS 2556 Part 2 2004 edition PDF, IS 2556 Part 2 edition 2004 PDF

What This Standard Covers

IS 2556 Part 2: 2004 specifies the detailed requirements for washdown water closets made of vitreous china, focusing on design, dimensions, performance, and testing to ensure sanitary efficiency and durability. This standard applies to manufacturers, designers, and quality inspectors involved in producing and evaluating pedestal water closets with various trap patterns used in residential and commercial sanitation systems in India.

Who Uses This Standard

  • Sanitaryware Manufacturers
  • Civil Engineers
  • Plumbing Designers
  • Quality Control Inspectors
  • Sanitation Consultants
  • Building Contractors
  • Regulatory Authorities

Key Topics Covered

Functional and connecting dimensions of washdown water closets
Design patterns and construction requirements
Water seal and flushing rim specifications
Anti-siphonage vent requirements
Load bearing and durability testing
Saw dust and splash tests for flushing efficiency
Marking and certification requirements
Sampling and inspection procedures
Material and surface finish standards
Performance tests including ball and toilet paper discharge
Installation and connection details
Water holding capacity and sealing tests

Table of Contents

1Scope

IS 2556 (Part 2): 2004 — Scope & Key Specifications

This part specifies functional and connecting dimensions for vitreous china water closets with various trap patterns, ensuring interchangeability and performance.


1. Scope Highlights:

  • Applies to vitreous china water closets with P-trap, S-trap, horizontal P-trap, and concealed S-trap.
  • Specifies dimensions for seat, outlet, inlet, water seal, and flushing connections.
  • Tests (Clause 8.6) require connection to flushing cisterns conforming to IS 774 or IS 7231.
  • Flushing pipe diameter: 40 mm normal.
  • Cistern height above WC: max 300 mm.

2. Key Functional Dimensions (Table 1, mm):

ParameterSymbolPattern 1,2,3,4
HeightA390 ± 10
Min Water Seal DepthH50
Width of WCJ360 ± 10
Seat bolt hole to frontK415 to 445
Seat bolt hole to flush rim back (max)L80
Width of opening (min)P240
Length of opening (min)Q290
Overall lengthS500-575 (Patterns 1,2), 500 Max (3), 600 Max (4)
Trap inlet depth (min)T75

3. Key Connecting Dimensions (Table 2, mm):

ParameterSymbolPattern 1,2,3,4
Flush inlet center height (P-trap)B345 +15/-25
Outlet center height from floor (P-trap)CI180 +15/-10
Internal outlet diameter (min)D180
External outlet diameterD11102 ± 5
Radius of free space from outlet center (min)D2175
Internal inlet diameterE250 ± 3 (P-trap), 55 +3/-1 (others)
Depth of inlet socket (min)
2References

IS 2556 Part 2 - References & Key Specifications

Referenced Standards (per Table 2):

IS No.Title
774:1984Specification for flushing cisterns (non-plastic) for water closets and urinals
2556 (Part 1):1994Vitreous sanitary appliances - General requirements
7231:1994Specification for plastic flushing cisterns for water closets and urinals
9140:1996Methods of sampling vitreous and fire clay sanitary appliances

Important Notes:

  • Dimension Correction:
    Replace D2 with D2/2 in Table 2, SI No. (vi).
  • Radius of Free Space:
    Measure radius from the outlet center; minimum distance = 40 mm from outlet end.
  • Rounding Off:
    Follow IS 2:1960 for rounding test results, retaining the same significant figures as specified.

Summary:

  • Use latest editions of referenced IS codes for compliance.
  • Dimension corrections ensure accurate fitting and testing of sanitary appliances.
  • Rounding rules maintain consistency in reporting test results.
flowchart LR
    A[IS 2556 Part 2] --> B[References to IS 774, 2556(Part1), 7231, 9140]
    B --> C[Dimension Corrections: D2 → D2/2]
    B --> D[Radius of free space ≥ 40 mm from outlet]
    B --> E[Rounding off as per IS 2:1960]

This ensures conformity with sanitary appliance standards and testing accuracy.

3General Requirements

IS 2556 Part 2 – General Requirements (Clause 3)

  • Scope: General requirements for vitreous sanitary appliances refer to IS 2556 Part 1 (1994) for:

    • Terminology
    • Materials
    • Manufacture
    • Glazing
    • Defects
    • Minimum thickness
    • Tolerances
    • Performance
    • Test methods
  • Key Reference Standards:

IS No.Title
IS 774 : 1984Specification for flushing cisterns (non-plastic)
IS 2556 (Part 1):1994Vitreous sanitary appliances – General requirements
IS 7231 : 1994Specification for plastic flushing cisterns
IS 9140 : 1996Sampling methods for vitreous and fire clay sanitary appliances
  • Rounding off: Follow IS 2:1960 for rounding numerical results, retaining significant figures equal to those in the specified values.

Summary Diagram:

graph TD
A[General Requirements] --> B[Terminology & Materials]
A --> C[Manufacture & Glazing]
A --> D[Defects & Thickness]
A --> E[Tolerances & Performance]
A --> F[Test Methods]
A --> G[Refer IS 2556 Part 1]

For detailed formulas and tables, refer to IS 2556 Part 1 as Part 2 defers to it for specifics.

4Patterns of Water Closets

IS 2556 Part 2: Patterns of Water Closets — Key Specifications

1. Patterns of Water Closets (Clause 4.1)

  • Pattern 1: Pedestal WC with independent cistern (Fig. 1)
  • Pattern 2: (Not explicitly detailed but similar to Pattern 1)
  • Pattern 3: Pedestal WC with independent cistern and horizontal outlet (Fig. 2)
  • Pattern 4: Pedestal WC with independent cistern and concealed S-trap (Fig. 3)

2. Functional Dimensions (Table 1, Clause 5)

ParameterPattern 1 & 2Pattern 3Pattern 4Unit (mm)
Height (A)390 ± 10390 ± 10390 ± 10mm
Depth of water seal (H)≥ 50≥ 50≥ 50mm
Width (J)360 ± 10360 ± 10360 ± 10mm
Seat bolt hole to front (K)415–445415–445415–445mm
Seat bolt hole to flush rim back (L)≤ 80≤ 80≤ 80mm
Width of opening (P)≥ 240≥ 240≥ 240mm
Length of opening (Q)≥ 290≥ 290≥ 290mm
Overall length (S)500–575≤ 500≤ 600mm
Trap inlet depth (T)≥ 75≥ 75≥ 75mm
Water surface back to front (W)≥ 150≥ 100≥ 150mm

3. Connecting Dimensions (Table 2, Clause 5)

ParameterPattern 1 & 2Pattern 3Pattern 4Unit (mm)
Flush inlet center height from floor (B)345 +15/-25SameSamemm
Outlet center height from floor (CI)180 +15/-10SameN/A
5Functional and Connecting Dimensions

IS 2556 (Part 2): Functional & Connecting Dimensions Summary


1. Functional Dimensions (Table 1, Clause 5)

All dimensions in mm for Patterns 1 to 4 (see respective figures):

ParameterSymbolValue (mm)Notes
HeightA390 ± 10Uniform for all patterns
Min Water Seal DepthH50Ensures trap seal
Width of WCJ360 ± 10Consistent width
Seat bolt hole to frontK415 to 445Seat fitting
Seat bolt hole to flush rim backLMax 80
Vertical line from back plate tip to flush rimOMax 70
Opening width (min)P240
Opening length (min)Q290
Overall lengthS500-575 (Patterns 1 & 2), Max 500 (Pattern 3), Max 600 (Pattern 4)For S-trap center vent, add 75 mm
Trap inlet depth (min)T75
Water surface back to frontW100-150 minPattern 2 has 100 min
Water surface side to sideW275-110 min

2. Connecting Dimensions (Table 2, Clause 5)

All dimensions in mm for Patterns 1 to 4:

ParameterSymbolPattern 1 & 2Pattern 3Pattern 4Notes
Flush inlet center height from floor (P-trap)B345 +15/-25SameSame
Outlet center height from floor (P-trap)CI180 +15/-10Same-
Distance end of trap to floor (S-trap)C220 ± 5--
Internal diameter of outlet (min)D1808080Ovality allowed
External diameter of outletD11102 ± 5SameSame
Radius of free space from outlet centerD21
6Construction and Design Requirements

IS 2556 Part 2: Construction & Design Requirements Summary

1. General Requirements

  • Conform to IS 2556 Part 1 for terminology, materials, manufacture, glazing, defects, minimum thickness, tolerances, performance, and test methods.

2. Functional Dimensions (Table 1, Clause 5) [All in mm]

ParameterSymbolPattern 1-4 Typical Values
HeightA390 ±10
Min Water Seal DepthH50
Width of Water ClosetJ360 ±10
Seat Bolt Hole to FrontK415 to 445
Seat Bolt Hole to Flush Rim Back (Max)L80
Width of Opening (Min)P240
Length of Opening (Min)Q290
Overall LengthS500-600 (varies by pattern)
Trap Inlet Depth (Min)T75
Water Surface Back to Front (Min)W100-150
Water Surface Side to Side (Min)W275-110

Note: For center vent in S trap, overall length = S + 75 mm.

3. Connecting Dimensions (Table 2, Clause 5) [All in mm]

ParameterSymbolPattern 1-4 Typical Values
Flush Inlet Center Height from Floor (P-trap)B345 +15/-25
Outlet Center Height from Floor (P-trap)CI180 +15/-10
Trap End to Floor (S-trap)C220 ±5
Internal Diameter of Outlet (Min)D180
External Diameter of OutletD11102 ±5
Radius of Free Space from Outlet Center (Min)D2175
Internal Diameter of InletE250 ±3 (Patterns 1 & 2), 55 +3/-1 (Patterns 3 & 4)
Depth of Inlet Socket (Min)F25
Seat Bolt Hole DiameterM15 ±2
Distance Between Seat Bolt HolesN
7Anti-Siphonage Vent and Connectors

IS 2556 (Part 2): Anti-Siphonage Vent and Connectors Key Points

1. Anti-Siphonage Vent (Clause 6.3 & 6.4.1)

  • Location: On outlet side of trap (water closet), at 45° angle (Fig. 4).
  • Dimension: Vent hole invert not below outlet centerline.
  • Pattern 3 (horizontal outlet): Vent provided in special connector.

2. Functional Dimensions (Table 1, Clause 5)

ParameterSymbolValue (mm)Notes
Depth of water seal (min)H50Ensures trap seal
Internal diameter of outlet (min)D180Standard outlet size
External diameter of outletD11102 ± 5For connectors
Trap inlet depth (min)T75Ensures proper trap function
Width of opening (min)P240For water closet seat
Length of opening (min)Q290For water closet seat

3. Connecting Dimensions (Table 2, Clause 5)

ParameterSymbolValue (mm)Notes
Height of outlet center from floor (P-trap)CI180 +15/-10Installation height
Length of grooved outlet (min)R40For secure pipe connection
Diameter of seat bolt holeM15 ± 2For seat fixing bolts
Distance between seat bolt holesN155-165Seat fitting

4. Testing (Clause 8.6)

  • Connect water closet to low-level cistern (IS 774 or IS 7231).
  • Height between closet top and cistern bottom ≤ 300 mm.
  • Use 40 mm diameter flushing pipe.
  • Test with cistern capacity as per appliance design.

Summary Diagram of Anti-Siphonage Vent Location

flowchart LR
    WC[Water Closet Trap Outlet]
    Vent[Anti-Siphonage Vent Hole]
    WC -->|45° angle| Vent
    Vent -->|Invert not below outlet centerline| WC

Note: Always refer

8Performance and Testing Procedures

IS 2556 Part 2: Performance & Testing Procedures Summary

Testing Procedure (Clause 8.6)

  • Connect water closet (WC) to a low-level cistern conforming to IS 774 or IS 7231.
  • Height between top of WC and bottom of cistern ≤ 300 mm.
  • Use a 40 mm diameter flushing pipe.
  • Use cistern capacity as per appliance design.
  • Tests per Clauses 8.1 to 8.7.

Key Functional Dimensions (Table 1, Clause 5) [mm]

ParameterPattern 1-4 (Typical)Notes
Height (A)390 ± 10Seat height
Water Seal Depth (H)≥ 50Minimum trap seal
Width of WC (J)360 ± 10Overall width
Seat bolt hole to front (K)415 to 445Seat fixing
Trap inlet depth (T)≥ 75Minimum depth
Overall length (S)500-575 (Patterns 1 & 2), up to 600 (Pattern 4)Length of WC

Connecting Dimensions (Table 2, Clause 5) [mm]

ParameterPattern 1-4 (Typical)Notes
Flush inlet height (B)345 +15/-25From floor (P-trap only)
Outlet centre height (CI)180 +15/-10From floor (P-trap only)
Internal outlet diameter (D1)≥ 80Minimum outlet size
Internal inlet diameter (E2)50 ± 3 (P-trap), 55 +3/-1 (others)Inlet socket size
Seat bolt hole diameter (M)15 ± 2For seat fixing bolts

Notes:

  • Ovality tolerances apply to inlet/outlet diameters.
  • Overall length for center vent in S-trap = S + 75 mm.
  • Rounding off results per IS 2:1960.

Diagram Concept (Simplified Flushing Setup)

flowchart TD
    Cistern[Low-level Cistern (IS 774 / IS 7231
9Sampling, Inspection and Lot Inspection

IS 2556 Part 2: Sampling, Inspection, and Lot Inspection

Key Points:

  • Sampling & Inspection:
    The standard refers to IS 9140 for detailed procedures on sampling, process inspection, and lot inspection of vitreous china sanitary appliances.

  • Flush Test Procedure (Clause 8.7.1):

    • Set up WC or cistern as per manufacturer instructions.
    • Fill with coloured water to design water seal level.
    • Clean and dry floor area for splash test.
    • Activate flush valve/cistern and observe splash over rim onto floor.
    • Repeat 5 times; isolated droplets ≤10 are acceptable and not grounds for rejection.
  • Rounding Off (IS 2:1960):
    Final test values must be rounded off as per IS 2 rules, matching the significant digits of the specified values.


Summary Table: Flush Splash Acceptance Criteria

Test RepetitionsSplash Droplets AllowedAcceptance Criteria
5≤ 10 isolated dropletsPass (No rejection)
> 10 droplets-Fail (Reject the lot)

Reference for Sampling & Inspection:

AspectStandard Reference
Sampling & Lot InspectionIS 9140
Rounding Off ValuesIS 2 : 1960

flowchart TD
    A[Start: Sample Selection] --> B[Process Inspection per IS 9140]
    B --> C{Flush Test (5 times)}
    C -->|Splash ≤10 droplets| D[Accept Sample]
    C -->|Splash >10 droplets| E[Reject Sample]
    D --> F[Lot Acceptance]
    E --> G[Lot Rejection]

Use IS 9140 for detailed sampling tables and acceptance criteria beyond flush testing.

10Marking and Certification

IS 2556 Part 2: Marking and Certification Key Points

  • BIS Certification Marking (Clause 10.2):
    Products may carry the BIS Standard Mark, indicating compliance with Indian Standards.

  • Use of Standard Mark (Clause 10.2.1):
    Governed by the Bureau of Indian Standards Act, 1986.

    • Licence for use granted by BIS under specific conditions.
    • Details available from BIS regional offices or official website.
  • BIS Contact and Regional Offices:
    Useful for certification queries and licensing:

    • Central (New Delhi), Eastern (Kolkata), Northern (Chandigarh), Southern (Chennai), Western (Mumbai)
    • Multiple branch offices across India.
  • Important Notes:

    • BIS owns copyright of publications; reproduction requires permission.
    • Free use allowed for implementation (symbols, sizes, type/grade designations).

Summary Table: BIS Certification Marking

ClauseDescriptionReference/Action
10.2BIS Standard Mark usageProduct marking allowed with BIS mark
10.2.1Licensing conditionsGoverned by BIS Act 1986, contact BIS

BIS Regional Offices (Sample)

RegionAddressPhone Numbers
CentralManak Bhavan, New Delhi2323 7617, 2323 3841
Eastern1/14 C.I.T. Scheme VII M, Kolkata2337 8499, 2337 8561, 2337 8626
NorthernSCO 335-336, Sector 34-A, Chandigarh260 3843, 260 9285
SouthernC.I.T. Campus, Chennai2254 1216, 2254 1442, 2254 2519
WesternManakalaya, Mumbai2832 9295, 2832 7858, 2832 7891

For detailed licensing terms and marking specifications, contact BIS directly or visit www.bis.gov.in.

Popular Questions About IS 2556 Part 2

?What are the specified dimensions for different patterns of washdown water closets?

IS 2556 Part 2 specifies the functional and connecting dimensions for four patterns of washdown water closets. Key points:

  • Patterns Covered:

    • Pattern 1: Pedestal WC with independent cistern (vertical outlet)
    • Pattern 3: Pedestal WC with independent cistern and horizontal outlet
    • Pattern 4: Pedestal WC with independent cistern and concealed S-trap
    • (Pattern 2 is also referenced but less detailed here)
  • Dimensions:

    • Functional and connecting dimensions are given in Tables 1 & 2 of the standard.
    • Dimensions are in millimeters.
    • Figures 1, 2, and 3 illustrate the patterns and dimension layouts.
  • Important Notes on Outlets:

    • Patterns 1 & 2: Outlet serrated externally, not glazed.
    • Pattern 3: Outlet without serration, glazed.
    • Pattern 4: Outlet not glazed.
  • Special Provision:

    • For Pattern 3 (horizontal outlet), an anti-siphonage vent is required in the special connector (Clause 6.4.1).

Typical Functional Dimensions (Example for Pattern 1 & 3)

ParameterPattern 1 (Vertical)Pattern 3 (Horizontal)
Height to Rim (H)~400 mm~400 mm
Outlet Diameter (D)100 mm100 mm
Trap Seal Depth (T)75 mm75 mm
Distance to Floor (F)As per installationAs per installation

(Exact dimensions should be verified from IS 2556 Part 2 Table 1 & 2)


Loading diagram...

Summary: Refer to IS 2556 Part 2 Tables 1 & 2 and Figures 1-3 for precise dimensions and tolerances for

?What performance tests are required to ensure flushing efficiency?

To ensure flushing efficiency per IS 2556 Part 2, the following performance tests are required:

1. Toilet Paper Test (Clause 8.1)

  • Fill WC to normal water seal level.
  • Place 6 pieces of usual toilet paper (150 mm × 115 mm, 0.05 mm thick) loosely crumpled.
  • Flush 4 times; at least 3 out of 4 flushes must discharge all paper completely.

2. Ball Test (Clause 3.7)

  • Drop 50 non-absorbent balls (mass 3.7 ± 0.1 g, diameter 20 ± 0.1 mm) into WC.
  • Flush 5 times.
  • Minimum 85% of balls must be flushed out over 5 tests.

3. Splash Test (Clause 8.7.1)

  • Use colored water to design water seal level.
  • Flush 5 times.
  • Observe splash over rim; up to 10 isolated droplets allowed without rejection.

4. Sawdust Test (Clause 8.6.2)

  • Sprinkle 20 g fine dry sawdust inside WC between water level and rim.
  • Flush once.
  • Sawdust must be cleaned below 40 mm of WC rim.

These tests collectively verify discharge capacity, blockage resistance, splash control, and flushing cleanliness.

?How is the anti-siphonage vent implemented and when is it mandatory?

Anti-siphonage Vent Implementation and Mandate (IS 2556 Part 2:2004)

  • When Mandatory:
    Per Clause 6.3, the anti-siphonage vent horn is required where mandated by the local sanitation authority. It is especially relevant for water closets to prevent siphoning of the trap seal.

  • Location & Orientation:

    • On the outlet side of the trap.
    • Positioned at a 45° angle (either right, left, or center as specified).
    • The invert (bottom) of the vent hole must not be below the central line of the outlet (see Fig. 4 of the standard).
  • For Pattern 3 Water Closets (Horizontal Outlet):
    Clause 6.4.1 states the anti-siphonage vent is incorporated in the special connector.

  • Dimensions:
    Refer to Fig. 4 in IS 2556 Part 2 for exact vent hole dimensions and placement details.


Summary Table

AspectDetails
MandatoryIf required by sanitation authority
LocationOutlet side of trap
Orientation45° angle (right/left/center)
Vent hole invert lineNot below outlet centerline
Pattern 3 WCVent in special connector

Loading diagram...

This vent prevents trap water seal loss due to siphoning, ensuring hygiene and odor control. Always confirm local authority requirements before installation.

?What load bearing capacity must the water closet withstand?

According to IS 2556 Part 2, Clause 8.5 (Load Bearing Test):

  • The water closet (WC) must withstand a load of 400 ± 5 kg or a force of 4 ± 0.05 kN.
  • This load is applied for 1 hour via a wooden beam of 100 mm × 100 mm cross-section placed across the center of the WC's top opening.
  • After the test, the WC shall show no damage or defects.

Summary:

ParameterValue
Load magnitude400 ± 5 kg (≈4 kN)
Load application1 hour
Load application methodWooden beam 100 × 100 mm
Acceptance criteriaNo damage or defect

This ensures the WC's structural integrity under typical user load conditions.

?What marking and certification requirements must manufacturers comply with?

Marking and Certification Requirements as per IS 2556 Part 2:

  • Manufacturer's Marking (Clause 10.1):
    Each water closet must be clearly and indelibly marked with:

    • Name or trade-mark of the manufacturer
    • Batch or lot number
  • BIS Certification Mark (Clause 10.2):

    • Products may bear the Standard Mark (BIS Mark) indicating conformity with the Indian Standard.
    • Use of the Standard Mark is regulated under the Bureau of Indian Standards Act, 1986.
    • Manufacturers must obtain a licence from BIS to use this mark.
    • Conditions and permissions for the Standard Mark are governed by BIS rules and can be obtained from BIS offices.

Summary:

RequirementDetails
Manufacturer MarkingName/trade-mark + Batch/lot number
BIS Standard MarkOptional, requires BIS licence under BIS Act

For licensing and further details, contact the nearest BIS regional office.

Loading diagram...

This ensures traceability and quality certification compliance.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 2556 Part 2. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required