IS 2556 Part 2: 2004 specifies the detailed requirements for washdown water closets made of vitreous china, focusing on design, dimensions, performance, and testing to ensure sanitary efficiency and durability. This standard applies to manufacturers, designers, and quality inspectors involved in producing and evaluating pedestal water closets with various trap patterns used in residential and commercial sanitation systems in India.
Overview
IS 2556 Part 2: 2004 specifies the detailed requirements for washdown water closets made of vitreous china, focusing on design, dimensions, performance, and testing to ensure sanitary efficiency and durability. This standard applies to manufacturers, designers, and quality inspectors involved in producing and evaluating pedestal water closets with various trap patterns used in residential and commercial sanitation systems in India.
Audience
Contents
Structure
IS 2556 (Part 2): 2004 — Scope & Key Specifications
This part specifies functional and connecting dimensions for vitreous china water closets with various trap patterns, ensuring interchangeability and performance.
| Parameter | Symbol | Pattern 1,2,3,4 |
|---|---|---|
| Height | A | 390 ± 10 |
| Min Water Seal Depth | H | 50 |
| Width of WC | J | 360 ± 10 |
| Seat bolt hole to front | K | 415 to 445 |
| Seat bolt hole to flush rim back (max) | L | 80 |
| Width of opening (min) | P | 240 |
| Length of opening (min) | Q | 290 |
| Overall length | S | 500-575 (Patterns 1,2), 500 Max (3), 600 Max (4) |
| Trap inlet depth (min) | T | 75 |
| Parameter | Symbol | Pattern 1,2,3,4 |
|---|---|---|
| Flush inlet center height (P-trap) | B | 345 +15/-25 |
| Outlet center height from floor (P-trap) | CI | 180 +15/-10 |
| Internal outlet diameter (min) | D1 | 80 |
| External outlet diameter | D11 | 102 ± 5 |
| Radius of free space from outlet center (min) | D21 | 75 |
| Internal inlet diameter | E2 | 50 ± 3 (P-trap), 55 +3/-1 (others) |
| Depth of inlet socket (min) |
IS 2556 Part 2 - References & Key Specifications
| IS No. | Title |
|---|---|
| 774:1984 | Specification for flushing cisterns (non-plastic) for water closets and urinals |
| 2556 (Part 1):1994 | Vitreous sanitary appliances - General requirements |
| 7231:1994 | Specification for plastic flushing cisterns for water closets and urinals |
| 9140:1996 | Methods of sampling vitreous and fire clay sanitary appliances |
flowchart LR
A[IS 2556 Part 2] --> B[References to IS 774, 2556(Part1), 7231, 9140]
B --> C[Dimension Corrections: D2 → D2/2]
B --> D[Radius of free space ≥ 40 mm from outlet]
B --> E[Rounding off as per IS 2:1960]
This ensures conformity with sanitary appliance standards and testing accuracy.
IS 2556 Part 2 – General Requirements (Clause 3)
Scope: General requirements for vitreous sanitary appliances refer to IS 2556 Part 1 (1994) for:
Key Reference Standards:
| IS No. | Title |
|---|---|
| IS 774 : 1984 | Specification for flushing cisterns (non-plastic) |
| IS 2556 (Part 1):1994 | Vitreous sanitary appliances – General requirements |
| IS 7231 : 1994 | Specification for plastic flushing cisterns |
| IS 9140 : 1996 | Sampling methods for vitreous and fire clay sanitary appliances |
graph TD
A[General Requirements] --> B[Terminology & Materials]
A --> C[Manufacture & Glazing]
A --> D[Defects & Thickness]
A --> E[Tolerances & Performance]
A --> F[Test Methods]
A --> G[Refer IS 2556 Part 1]
For detailed formulas and tables, refer to IS 2556 Part 1 as Part 2 defers to it for specifics.
IS 2556 Part 2: Patterns of Water Closets — Key Specifications
| Parameter | Pattern 1 & 2 | Pattern 3 | Pattern 4 | Unit (mm) |
|---|---|---|---|---|
| Height (A) | 390 ± 10 | 390 ± 10 | 390 ± 10 | mm |
| Depth of water seal (H) | ≥ 50 | ≥ 50 | ≥ 50 | mm |
| Width (J) | 360 ± 10 | 360 ± 10 | 360 ± 10 | mm |
| Seat bolt hole to front (K) | 415–445 | 415–445 | 415–445 | mm |
| Seat bolt hole to flush rim back (L) | ≤ 80 | ≤ 80 | ≤ 80 | mm |
| Width of opening (P) | ≥ 240 | ≥ 240 | ≥ 240 | mm |
| Length of opening (Q) | ≥ 290 | ≥ 290 | ≥ 290 | mm |
| Overall length (S) | 500–575 | ≤ 500 | ≤ 600 | mm |
| Trap inlet depth (T) | ≥ 75 | ≥ 75 | ≥ 75 | mm |
| Water surface back to front (W) | ≥ 150 | ≥ 100 | ≥ 150 | mm |
| Parameter | Pattern 1 & 2 | Pattern 3 | Pattern 4 | Unit (mm) |
|---|---|---|---|---|
| Flush inlet center height from floor (B) | 345 +15/-25 | Same | Same | mm |
| Outlet center height from floor (CI) | 180 +15/-10 | Same | N/A |
IS 2556 (Part 2): Functional & Connecting Dimensions Summary
All dimensions in mm for Patterns 1 to 4 (see respective figures):
| Parameter | Symbol | Value (mm) | Notes |
|---|---|---|---|
| Height | A | 390 ± 10 | Uniform for all patterns |
| Min Water Seal Depth | H | 50 | Ensures trap seal |
| Width of WC | J | 360 ± 10 | Consistent width |
| Seat bolt hole to front | K | 415 to 445 | Seat fitting |
| Seat bolt hole to flush rim back | L | Max 80 | |
| Vertical line from back plate tip to flush rim | O | Max 70 | |
| Opening width (min) | P | 240 | |
| Opening length (min) | Q | 290 | |
| Overall length | S | 500-575 (Patterns 1 & 2), Max 500 (Pattern 3), Max 600 (Pattern 4) | For S-trap center vent, add 75 mm |
| Trap inlet depth (min) | T | 75 | |
| Water surface back to front | W | 100-150 min | Pattern 2 has 100 min |
| Water surface side to side | W2 | 75-110 min |
All dimensions in mm for Patterns 1 to 4:
| Parameter | Symbol | Pattern 1 & 2 | Pattern 3 | Pattern 4 | Notes |
|---|---|---|---|---|---|
| Flush inlet center height from floor (P-trap) | B | 345 +15/-25 | Same | Same | |
| Outlet center height from floor (P-trap) | CI | 180 +15/-10 | Same | - | |
| Distance end of trap to floor (S-trap) | C2 | 20 ± 5 | - | - | |
| Internal diameter of outlet (min) | D1 | 80 | 80 | 80 | Ovality allowed |
| External diameter of outlet | D11 | 102 ± 5 | Same | Same | |
| Radius of free space from outlet center | D21 |
IS 2556 Part 2: Construction & Design Requirements Summary
| Parameter | Symbol | Pattern 1-4 Typical Values |
|---|---|---|
| Height | A | 390 ±10 |
| Min Water Seal Depth | H | 50 |
| Width of Water Closet | J | 360 ±10 |
| Seat Bolt Hole to Front | K | 415 to 445 |
| Seat Bolt Hole to Flush Rim Back (Max) | L | 80 |
| Width of Opening (Min) | P | 240 |
| Length of Opening (Min) | Q | 290 |
| Overall Length | S | 500-600 (varies by pattern) |
| Trap Inlet Depth (Min) | T | 75 |
| Water Surface Back to Front (Min) | W | 100-150 |
| Water Surface Side to Side (Min) | W2 | 75-110 |
Note: For center vent in S trap, overall length = S + 75 mm.
| Parameter | Symbol | Pattern 1-4 Typical Values |
|---|---|---|
| Flush Inlet Center Height from Floor (P-trap) | B | 345 +15/-25 |
| Outlet Center Height from Floor (P-trap) | CI | 180 +15/-10 |
| Trap End to Floor (S-trap) | C2 | 20 ±5 |
| Internal Diameter of Outlet (Min) | D1 | 80 |
| External Diameter of Outlet | D11 | 102 ±5 |
| Radius of Free Space from Outlet Center (Min) | D21 | 75 |
| Internal Diameter of Inlet | E2 | 50 ±3 (Patterns 1 & 2), 55 +3/-1 (Patterns 3 & 4) |
| Depth of Inlet Socket (Min) | F | 25 |
| Seat Bolt Hole Diameter | M | 15 ±2 |
| Distance Between Seat Bolt Holes | N |
IS 2556 (Part 2): Anti-Siphonage Vent and Connectors Key Points
| Parameter | Symbol | Value (mm) | Notes |
|---|---|---|---|
| Depth of water seal (min) | H | 50 | Ensures trap seal |
| Internal diameter of outlet (min) | D1 | 80 | Standard outlet size |
| External diameter of outlet | D11 | 102 ± 5 | For connectors |
| Trap inlet depth (min) | T | 75 | Ensures proper trap function |
| Width of opening (min) | P | 240 | For water closet seat |
| Length of opening (min) | Q | 290 | For water closet seat |
| Parameter | Symbol | Value (mm) | Notes |
|---|---|---|---|
| Height of outlet center from floor (P-trap) | CI | 180 +15/-10 | Installation height |
| Length of grooved outlet (min) | R | 40 | For secure pipe connection |
| Diameter of seat bolt hole | M | 15 ± 2 | For seat fixing bolts |
| Distance between seat bolt holes | N | 155-165 | Seat fitting |
flowchart LR
WC[Water Closet Trap Outlet]
Vent[Anti-Siphonage Vent Hole]
WC -->|45° angle| Vent
Vent -->|Invert not below outlet centerline| WC
Note: Always refer
IS 2556 Part 2: Performance & Testing Procedures Summary
| Parameter | Pattern 1-4 (Typical) | Notes |
|---|---|---|
| Height (A) | 390 ± 10 | Seat height |
| Water Seal Depth (H) | ≥ 50 | Minimum trap seal |
| Width of WC (J) | 360 ± 10 | Overall width |
| Seat bolt hole to front (K) | 415 to 445 | Seat fixing |
| Trap inlet depth (T) | ≥ 75 | Minimum depth |
| Overall length (S) | 500-575 (Patterns 1 & 2), up to 600 (Pattern 4) | Length of WC |
| Parameter | Pattern 1-4 (Typical) | Notes |
|---|---|---|
| Flush inlet height (B) | 345 +15/-25 | From floor (P-trap only) |
| Outlet centre height (CI) | 180 +15/-10 | From floor (P-trap only) |
| Internal outlet diameter (D1) | ≥ 80 | Minimum outlet size |
| Internal inlet diameter (E2) | 50 ± 3 (P-trap), 55 +3/-1 (others) | Inlet socket size |
| Seat bolt hole diameter (M) | 15 ± 2 | For seat fixing bolts |
flowchart TD
Cistern[Low-level Cistern (IS 774 / IS 7231
IS 2556 Part 2: Sampling, Inspection, and Lot Inspection
Sampling & Inspection:
The standard refers to IS 9140 for detailed procedures on sampling, process inspection, and lot inspection of vitreous china sanitary appliances.
Flush Test Procedure (Clause 8.7.1):
Rounding Off (IS 2:1960):
Final test values must be rounded off as per IS 2 rules, matching the significant digits of the specified values.
| Test Repetitions | Splash Droplets Allowed | Acceptance Criteria |
|---|---|---|
| 5 | ≤ 10 isolated droplets | Pass (No rejection) |
| > 10 droplets | - | Fail (Reject the lot) |
| Aspect | Standard Reference |
|---|---|
| Sampling & Lot Inspection | IS 9140 |
| Rounding Off Values | IS 2 : 1960 |
flowchart TD
A[Start: Sample Selection] --> B[Process Inspection per IS 9140]
B --> C{Flush Test (5 times)}
C -->|Splash ≤10 droplets| D[Accept Sample]
C -->|Splash >10 droplets| E[Reject Sample]
D --> F[Lot Acceptance]
E --> G[Lot Rejection]
Use IS 9140 for detailed sampling tables and acceptance criteria beyond flush testing.
IS 2556 Part 2: Marking and Certification Key Points
BIS Certification Marking (Clause 10.2):
Products may carry the BIS Standard Mark, indicating compliance with Indian Standards.
Use of Standard Mark (Clause 10.2.1):
Governed by the Bureau of Indian Standards Act, 1986.
BIS Contact and Regional Offices:
Useful for certification queries and licensing:
Important Notes:
| Clause | Description | Reference/Action |
|---|---|---|
| 10.2 | BIS Standard Mark usage | Product marking allowed with BIS mark |
| 10.2.1 | Licensing conditions | Governed by BIS Act 1986, contact BIS |
| Region | Address | Phone Numbers |
|---|---|---|
| Central | Manak Bhavan, New Delhi | 2323 7617, 2323 3841 |
| Eastern | 1/14 C.I.T. Scheme VII M, Kolkata | 2337 8499, 2337 8561, 2337 8626 |
| Northern | SCO 335-336, Sector 34-A, Chandigarh | 260 3843, 260 9285 |
| Southern | C.I.T. Campus, Chennai | 2254 1216, 2254 1442, 2254 2519 |
| Western | Manakalaya, Mumbai | 2832 9295, 2832 7858, 2832 7891 |
For detailed licensing terms and marking specifications, contact BIS directly or visit www.bis.gov.in.
Frequently Asked
IS 2556 Part 2 specifies the functional and connecting dimensions for four patterns of washdown water closets. Key points:
Patterns Covered:
Dimensions:
Important Notes on Outlets:
Special Provision:
| Parameter | Pattern 1 (Vertical) | Pattern 3 (Horizontal) |
|---|---|---|
| Height to Rim (H) | ~400 mm | ~400 mm |
| Outlet Diameter (D) | 100 mm | 100 mm |
| Trap Seal Depth (T) | 75 mm | 75 mm |
| Distance to Floor (F) | As per installation | As per installation |
(Exact dimensions should be verified from IS 2556 Part 2 Table 1 & 2)
Loading diagram...
Summary: Refer to IS 2556 Part 2 Tables 1 & 2 and Figures 1-3 for precise dimensions and tolerances for
To ensure flushing efficiency per IS 2556 Part 2, the following performance tests are required:
These tests collectively verify discharge capacity, blockage resistance, splash control, and flushing cleanliness.
Anti-siphonage Vent Implementation and Mandate (IS 2556 Part 2:2004)
When Mandatory:
Per Clause 6.3, the anti-siphonage vent horn is required where mandated by the local sanitation authority. It is especially relevant for water closets to prevent siphoning of the trap seal.
Location & Orientation:
For Pattern 3 Water Closets (Horizontal Outlet):
Clause 6.4.1 states the anti-siphonage vent is incorporated in the special connector.
Dimensions:
Refer to Fig. 4 in IS 2556 Part 2 for exact vent hole dimensions and placement details.
| Aspect | Details |
|---|---|
| Mandatory | If required by sanitation authority |
| Location | Outlet side of trap |
| Orientation | 45° angle (right/left/center) |
| Vent hole invert line | Not below outlet centerline |
| Pattern 3 WC | Vent in special connector |
Loading diagram...
This vent prevents trap water seal loss due to siphoning, ensuring hygiene and odor control. Always confirm local authority requirements before installation.
According to IS 2556 Part 2, Clause 8.5 (Load Bearing Test):
Summary:
| Parameter | Value |
|---|---|
| Load magnitude | 400 ± 5 kg (≈4 kN) |
| Load application | 1 hour |
| Load application method | Wooden beam 100 × 100 mm |
| Acceptance criteria | No damage or defect |
This ensures the WC's structural integrity under typical user load conditions.
Marking and Certification Requirements as per IS 2556 Part 2:
Manufacturer's Marking (Clause 10.1):
Each water closet must be clearly and indelibly marked with:
BIS Certification Mark (Clause 10.2):
Summary:
| Requirement | Details |
|---|---|
| Manufacturer Marking | Name/trade-mark + Batch/lot number |
| BIS Standard Mark | Optional, requires BIS licence under BIS Act |
For licensing and further details, contact the nearest BIS regional office.