IS 2556 Part 17:2001 specifies the requirements for wall mounted bidets made of vitreous china, focusing on patterns, construction, dimensions, tolerances, finish, inspection, and marking. It applies to manufacturers, designers, and quality controllers involved in producing or installing wall mounted bidets to ensure aesthetic appeal, hygienic performance, and structural reliability in sanitary installations.
Overview
IS 2556 Part 17:2001 specifies the requirements for wall mounted bidets made of vitreous china, focusing on patterns, construction, dimensions, tolerances, finish, inspection, and marking. It applies to manufacturers, designers, and quality controllers involved in producing or installing wall mounted bidets to ensure aesthetic appeal, hygienic performance, and structural reliability in sanitary installations.
Audience
Contents
Structure
IS 2556 Part 17: Scope — Key Dimensions & Specifications
| Parameter | Pattern 1 | Pattern 2 | Unit (mm) |
|---|---|---|---|
| Length, Max (L) | 600 | 600 | mm |
| Breadth (W) | 360 ± 20 | 360 ± 20 | mm |
| Height (H) | 350 ± 10 | 350 ± 10 | mm |
| Length of opening, Min (L1) | 375 | 375 | mm |
| Width of opening, Min (W1) | 220 | 220 | mm |
| Parameter | Pattern 1 | Pattern 2 | Unit (mm) |
|---|---|---|---|
| Diameter of tap hole (d1) | 35 ± 2 | 35 ± 2 | mm |
| Distance between two outer tap holes, Min (N) | 150 | 150 | mm |
| Distance centre tap hole to pop-up hole, if provided (c) | 50 (Min) | NA | mm |
| Distance centre tap hole to edge of rim/bowl, Max (b) | 80 | 80 | mm |
| Distance centre tap hole to waste hole centre, Max (8) | 170 | 170 | mm |
| Vertical distance tap platform to waste hole lower plane (p) | 250 | 250 | mm |
| Distance waste hole lower plane to bidet lower portion (m) | 100 | 100 | mm |
| Radius of free space under tap hole: | |||
| - Height 0 to 5 mm (r) | 25 | 25 | mm |
| - Height ≥ 5 mm (r) | 30 | 30 | mm |
| Wall thickness near tap hole (S), Max | 18 | 18 | mm |
IS 2556 Part 17: Key References and Specifications
Referenced Standards:
This part refers to various Indian Standards (IS) current at publication. Users should check for the latest editions for compliance.
Dimensions (Clause 6.1):
Rounding Off (IS 2:1960):
Numerical results must be rounded off as per IS 2:1960 rules, retaining the same number of significant digits as the specified value.
| Dimension Type | Parameter | Value (mm) | Tolerance (± mm) |
|---|---|---|---|
| Functional (Table 1) | Height | 500 | 2 |
| Connecting (Table 2) | Outlet Diameter | 40 | 1 |
flowchart LR
A[Start: Design/Check] --> B{Dimension Type?}
B -->|Functional| C[Refer Table 1]
B -->|Connecting| D[Refer Table 2]
C --> E[Apply Dimensions]
D --> E
E --> F[Perform Test/Analysis]
F --> G[Round off per IS 2:1960]
G --> H[Verify Compliance]
IS 2556 Part 17: General Requirements Summary
Dimensions:
Compliance with IS 2556 Part 1:
Rounding Off Values:
| Aspect | Reference/Requirement |
|---|---|
| Functional dimensions | Table 1 (IS 2556 Part 17) |
| Connecting dimensions | Table 2 (IS 2556 Part 17) |
| Materials & Manufacture | IS 2556 Part 1 |
| Rounding off values | IS 2:1960 rules, maintain significant figures |
If you need specific dimension tables or formulas, please specify which part or dimension type.
IS 2556 Part 17: Patterns and Construction of Wall Mounted Bidets
| Description | Pattern 1 | Pattern 2 |
|---|---|---|
| Length, Max (L) | 600 | 600 |
| Breadth (W) | 360 ± 20 | 360 ± 20 |
| Height (H) | 350 ± 10 | 350 ± 10 |
| Length of opening, Min (L1) | 375 | 375 |
| Width of opening, Min (W1) | 220 | 220 |
| Description | Pattern 1 | Pattern 2 |
|---|---|---|
| Diameter of tap hole (d1) | 35 ± 2 | 35 ± 2 |
| Distance between outer tap holes, Min (N) | 150 | 150 |
| Centre tap hole to pop-up hole, Min (c) | 50 | NA |
| Centre tap hole to rim edge, Max (b) | 80 | 80 |
| Centre tap hole to waste hole, Max (8) | 170 | 170 |
| Vertical tap platform to waste hole, Max (p) | 250 | 250 |
| Waste hole bottom to bidet bottom, Min (m) | 100 | 100 |
| Radius of free space below tap fitting hole (r): | ||
| - 0 to 5 mm height | 25 | 25 |
| - Above 5 mm height | 30 | 30 |
| Wall thickness at tap hole (S), Max | 18 | 18 |
| Distance between fixing holes (N) | 230 ± 5 | 230 ± 5 |
| Fixing hole dimension ( |
IS 2556 (Part 17): Materials and Finish - Key Specifications
| Description | Pattern 1 | Pattern 2 |
|---|---|---|
| Length, Max (L) | 600 mm | 600 mm |
| Breadth (W) | 360 ± 20 mm | 360 ± 20 mm |
| Height (H) | 350 ± 10 mm | 350 ± 10 mm |
| Length of opening, Min (L1) | 375 mm | 375 mm |
| Width of opening, Min (W1) | 220 mm | 220 mm |
| Description | Pattern 1 | Pattern 2 |
|---|---|---|
| Diameter of tap hole (d1) | 35 ± 2 mm | 35 ± 2 mm |
| Distance between two outer tap holes, Min (N) | 150 mm | 150 mm |
| Distance centre tap hole to pop-up hole (c) | ≥ 50 mm | N/A |
| Distance centre tap hole to edge of rim/bowl, Max (b) | 80 mm | 80 mm |
| Distance centre tap hole to centre waste hole, Max (δ) | 170 mm | 170 mm |
| Vertical distance tap platform to lower plane waste hole (p) | 250 mm | 250 mm |
| Distance lower plane waste hole to lower bidet portion (m) | ≥ 100 mm | ≥ 100 mm |
| Radius of free space below tap fitting hole (r) | 25 mm (0-5 mm height), 30 mm (≥5 mm height) | Same |
| Wall thickness at tap fitting hole (S), Max | 18 mm | 18 mm |
| Distance between fixing holes (N) | 230 ± 5 mm | 230 ± 5 mm |
IS 2556 Part 17: Dimensions & Tolerances for Bidets
| Parameter | Symbol | Pattern 1 | Pattern 2 |
|---|---|---|---|
| Length, Max | L | 600 mm | 600 mm |
| Breadth | W | 360 ± 20 mm | 360 ± 20 mm |
| Height | H | 350 ± 10 mm | 350 ± 10 mm |
| Length of opening, Min | L1 | 375 mm | 375 mm |
| Width of opening, Min | W1 | 220 mm | 220 mm |
| Parameter | Symbol | Pattern 1 | Pattern 2 |
|---|---|---|---|
| Diameter of tap hole | d1 | 35 ± 2 mm | 35 ± 2 mm |
| Distance between two outer tap holes, Min | N | 150 mm | 150 mm |
| Distance centre tap hole to pop-up hole | c | ≥ 50 mm | NA |
| Distance centre tap hole to rim edge, Max | b | 80 mm | 80 mm |
| Distance tap hole to waste hole centre, Max | 8 | 170 mm | 170 mm |
| Vertical distance tap platform to waste hole | p | 250 mm | 250 mm |
| Distance waste hole lower plane to bidet bottom, Min | m | 100 mm | 100 mm |
| Radius of cylinder below tap hole edge (0–5 mm height) | r | 25 mm | 25 mm |
| Radius of cylinder below tap hole edge (≥5 mm height) | r | 30 mm | 30 mm |
| Wall thickness near tap hole, Max | S | 18 mm | 18 mm |
| Distance between fixing holes | N | 230 ± 5 mm | 230 ± 5 mm |
| Fixing hole dimension (elliptical) | d4 | (30×25 |
IS 2556 Part 17: Marking (Clause 10.2 BIS Certification Marking)
| Marking Element | Description |
|---|---|
| Manufacturer’s ID | Name or trademark |
| Standard Number | IS 2556 (Part 17): 2001 |
| BIS Standard Mark | Optional, indicates certification |
flowchart LR
A[Bidet] --> B{Marking}
B --> C[Manufacturer's Name/Trademark]
B --> D[IS 2556 (Part 17): 2001]
B --> E[BIS Standard Mark (Optional)]
This ensures traceability and quality assurance per IS 2556 Part 17.
IS 2556 (Part 17): 2001 - Load Test for Wall Mounted Bidets
graph TB
A[Wooden Beam 100x100 mm] -->|Load 400 ± 5 kg| B[Bidet Top Opening]
B --> C[Wall with Mortar Layer]
C --> D[Fastening]
This load test ensures structural integrity and fastening reliability under specified load conditions.
IS 2556 Part 17: Sampling, Process Inspection & Lot Inspection
Reference Standard:
Sampling, process inspection, and lot inspection methods are as per IS 9140 (Sampling Procedures for Inspection by Attributes).
Key Points from IS 9140:
Process Inspection:
Continuous monitoring during manufacturing to ensure conformity with specifications.
Lot Inspection:
Final inspection of a batch (lot) before acceptance or rejection.
Rounding off Results:
Follow IS 2:1960 rules for rounding numerical values—maintain the same number of significant digits as specified.
| Lot Size (N) | Sample Size (n) | Acceptance Number (Ac) | Rejection Number (Re) |
|---|---|---|---|
| 2 to 8 | 2 | 0 | 1 |
| 9 to 15 | 3 | 0 | 1 |
| 16 to 25 | 5 | 0 | 1 |
| 26 to 50 | 8 | 1 | 2 |
| 51 to 90 | 13 | 1 | 2 |
| 91 to 150 | 20 | 2 | 3 |
| 151 to 280 | 32 | 3 | 4 |
Note: Actual sample size and acceptance criteria depend on the AQL and inspection level.
flowchart TD
A[Start: Lot Produced] --> B[Process Inspection]
B --> C{Conforms?}
C -- Yes --> D[Continue Production]
C -- No --> E[Correct Process]
D --> F[Lot Inspection]
F --> G{Accept Lot?}
G -- Yes --> H[Dispatch Lot]
G -- No --> I[Reject Lot / Rework]
In brief: Use IS 9140 for sampling
IS 2556 Part 17 (2001) - BIS Certification Marking
| Aspect | Specification |
|---|---|
| Marking Type | BIS Standard Mark (optional) |
| Required Information | BIS logo, License No., IS number |
| Location | On bidet, visible & permanent |
| Purpose | Indicates compliance to IS 2556 |
flowchart LR
A[Bidet] --> B{Marking}
B -->|Optional| C[BIS Standard Mark]
C --> D[Includes BIS logo]
C --> E[License Number]
C --> F[IS Number - 2556 Part 17]
D & E & F --> G[Visible & Permanent on Product]
For detailed marking style, refer to BIS guidelines on certification marks.
IS 2556 Part 17 — Committee Composition Summary
The composition of the Committee responsible for this standard is detailed in Annex A of IS 2556 Part 17:2001. It includes representatives from:
Key points:
| Organization | Representative(s) |
|---|---|
| Delhi Jal Board, New Delhi | Hydraulic Engineer, Deputy Hydraulic Engineer (Alternate) |
| Central Building Research Institute, Roorkee | Shri Suresh Kumar Sharma, Shri Ajay Singh (Alternate) |
| Hindustan Sanitaryware and Industries Ltd | Shri R.K. Somany (Convener) |
| Kirloskar Brothers Ltd, Pune | Shri R.D. Kulkarni, Shri S.V. Jadav (Alternate) |
| BIS Directorate General | Shri S.K. Jain (Director & Head CED) |
If you need specific formulas or tables, they are not provided under Committee Composition but focus on product dimensions and certification marking elsewhere in the standard.
graph TD
A[IS 2556 Part 17 Committee] --> B[Government Bodies]
A --> C[Research Institutes]
A --> D[Industry Representatives]
A --> E[BIS Officials]
B --> B1[Delhi Jal Board]
B --> B2[Kerala Water Authority]
Frequently Asked
IS 2556 Part 17: Wall Mounted Bidets Dimensions & Tolerances
| Parameter | Pattern 1 | Pattern 2 |
|---|---|---|
| Length, Max (L) | 600 mm | 600 mm |
| Breadth (W) | 360 ± 20 mm | 360 ± 20 mm |
| Height (H) | 350 ± 10 mm | 350 ± 10 mm |
| Length of opening, Min (L1) | 375 mm | 375 mm |
| Width of opening, Min (W1) | 220 mm | 220 mm |
| Parameter | Pattern 1 | Pattern 2 |
|---|---|---|
| Diameter of tap hole (d1) | 35 ± 2 mm | 35 ± 2 mm |
| Distance between two outer tap holes, Min (N) | 150 mm | 150 mm |
| Distance centre tap hole to pop-up hole (c) | ≥ 50 mm | NA |
| Distance centre tap hole to rim edge, Max (b) | 80 mm | 80 mm |
| Distance centre tap hole to waste hole, Max (8) | 170 mm | 170 mm |
| Vertical distance tap platform to waste hole, Max (p) | 250 mm | 250 mm |
| Distance waste hole lower plane to bidet bottom, Min (m) | 100 mm | 100 mm |
| Radius of free space below tap fitting hole (r) | 25 mm (0-5 mm height), 30 mm (≥5 mm height) | Same |
| Wall thickness near tap hole (S), Max | 18 mm | 18 mm |
| Distance between fixing holes (N) | 230 ± 5 mm | 230 ± 5 mm |
| Fixing hole dimension (elliptical d4) | (30 × 25) ± 3 mm | (30 × 25) ± 3 mm |
According to IS 2556 Part 17 for wall mounted bidets:
This ensures durability, hygiene, and proper installation.
Loading diagram...
Fixing and Supporting Wall Mounted Bidets as per IS 2556 Part 17
Loading diagram...
This ensures stable, durable, and strain-free installation of wall mounted bidets.
Load Testing Requirements for Wall Mounted Bidets (IS 2556 Part 17)
This ensures structural stability and durability under expected service loads.
Loading diagram...
Marking and Certification Requirements as per IS 2556 Part 17:
Clause 10.1:
Each bidet must be clearly and indelibly marked at a suitable place with:
Clause 10.2:
Manufacturers may also mark the bidet with the BIS Standard Mark to indicate certification.
Additional:
Compliance with general requirements in IS 2556 Part 1 is mandatory, covering terminology, materials, manufacture, glazing, defects, minimum thickness, performance, and test methods.
| Requirement | Details |
|---|---|
| Manufacturer's Marking | Name or trade-mark, Batch/Lot no. |
| BIS Certification Mark | Optional marking with BIS Standard Mark |
| Compliance | IS 2556 Part 1 general requirements |
Loading diagram...
Ask AI about any clause, requirement, or provision in IS 2556 Part 17. Get instant, clause-cited responses powered by our indexed library.