IS 2556 Part 14:1995 specifies the requirements for integrated vitreous china squatting pans, covering their patterns, dimensions, construction, finish, testing, inspection, and marking. This standard ensures functional performance and compatibility with plumbing systems, focusing on the long pattern 500 design while allowing for other sizes by agreement. It applies to manufacturers, engineers, and sanitation authorities involved in the design, production, installation, and quality assurance of integrated squatting pans in sanitary installations.
Overview
IS 2556 Part 14:1995 specifies the requirements for integrated vitreous china squatting pans, covering their patterns, dimensions, construction, finish, testing, inspection, and marking. This standard ensures functional performance and compatibility with plumbing systems, focusing on the long pattern 500 design while allowing for other sizes by agreement. It applies to manufacturers, engineers, and sanitation authorities involved in the design, production, installation, and quality assurance of integrated squatting pans in sanitary installations.
Audience
Contents
Structure
Scope of IS 2556 Part 14: Integrated Vitreous Squatting Pans
This standard specifies requirements for patterns, dimensions, tolerances, construction, finish, tests, inspection, and marking for integrated vitreous squatting pans.
Functional Dimensions (Table 1, Fig. 1):
| Parameter | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100 ± 3° |
| Depth of water seal, Min | T | 50 |
Connecting Dimensions (Table 2):
| Parameter | Symbol | Value (mm) |
|---|---|---|
| Depth of flush inlet socket | a | ≥ 25 |
| Distance from flush inlet socket end to outlet | b | ≥ 70 |
| Internal dia. of outlet | d1 | ≥ 80 |
| External dia. of outlet | d2 | 102 ± 5 |
| Internal dia. of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet | m | ≥ 40 |
| Centre of outlet height from bottom | h' | 140 |
| Outlet angle with vertical | e1 | 104° |
Two-Piece Bend Dimensions (Table 3, Fig. 3):
| Parameter | Symbol | Value (mm) |
|---|---|---|
| Internal dia. of outlet | d1 | ≥ 80 |
| External dia. of outlet | d2 | 102 ± 5 |
| Internal dia. of inlet socket | d5 | 115 |
| Depth of inlet socket | f | ≥ 40 |
| Height of bend | h | 207 |
IS 2556 Part 14 - Key References, Dimensions & Specifications
| Description | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Value (mm) |
|---|---|---|
| Depth of flush inlet socket | a | ≥ 25 |
| Distance from flush inlet socket end to outlet outside | b | ≥ 70 |
| Dia of outlet, internal (ovality allowed) | d1 | ≥ 80 |
| Dia of outlet, external (ovality allowed) | d2 | 102 ± 5 |
| Internal dia of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet | m | ≥ 40 |
| Distance of outlet center from pan bottom | h | 140 |
| Angle of outlet with vertical plane | ℮1 | 104° |
| Description | Symbol | Value (mm) |
|---|---|---|
| Internal dia of outlet (ovality allowed) | d1 | ≥ 80 |
| External dia of outlet (ovality allowed) | d4 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | ≥ 40 |
| Height of bend | h | 207 |
IS 2556 Part 14 — Terminology & Key Specifications for Integrated Squatting Pans
| Description | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Value (mm) |
|---|---|---|
| Depth of flush inlet socket (Min) | a | 25 |
| Distance flush inlet socket end to outlet outside (Min) | b | 70 |
| Internal dia of outlet (Min) | d1 | 80 |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet (Min) | m | 40 |
| Distance centre of outlet from pan bottom | h | 140 |
| Angle of outlet with vertical plane | ℮1 | 104° |
| Description | Symbol | Value (mm) |
|---|---|---|
| Internal dia of outlet | d1 | 80 (Min) |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket (Min) | f | 40 |
| Height of bend | h | 207 |
IS 2556 Part 14 — Patterns and Sizes: Key Dimensions & Specifications
| Description | Symbol | Long Pattern 500 (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Long Pattern 500 (mm) |
|---|---|---|
| Depth of flush inlet socket | a | ≥ 25 |
| Distance from end of flush inlet socket to outlet outside | b | ≥ 70 |
| Internal dia of outlet (ovality allowed) | d1 | ≥ 80 |
| External dia of outlet (ovality allowed) | d2 | 102 ± 5 |
| Internal dia of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet | m | ≥ 40 |
| Distance of outlet center from pan bottom | h' | 140 |
| Angle of outlet with vertical plane | ℮1 | 104° |
| Description | Symbol | Long Pattern 500 (mm) |
|---|---|---|
| Internal dia of outlet (ovality allowed) | d1 | ≥ 80 |
| External dia of outlet (ovality allowed) | d. | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | ≥ 40 |
| Height of the bend |
IS 2556 Part 14: Dimensions and Tolerances for Squatting Pan (Long Pattern 500)
| Description | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Value (mm) |
|---|---|---|
| Internal dia of outlet | d1 | ≥ 80 |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | ≥ 40 |
| Height of the bend | h | 207 |
flowchart LR
A[Squatting Pan] --> B[Functional Dimensions]
B --> C[Length (L) = 500 mm]
B --> D[Height (h1) = 320 ± 10 mm]
B --> E[Slope (z) = 100° ± 3°]
B --> F[Water Seal Depth (T) ≥ 50 mm]
A --> G
| Description | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Value (mm) |
|---|---|---|
| Depth of flush inlet socket | a | ≥ 25 |
| Distance from flush inlet socket end to outlet outside | b | ≥ 70 |
| Internal dia of outlet | d1 | ≥ 80 |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet | m | ≥ 40 |
| Distance of outlet center from pan bottom | h | 140 |
| Angle of outlet with vertical plane | ℮1 | 104° |
| Description | Symbol | Value (mm) |
|---|---|---|
| Internal dia of outlet | d1 | ≥ 80 |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | ≥ 40 |
| Height of the bend | h | 207 |
1. Surface Finish (Clause 1.18):
2. Glazing Requirements:
| Parameter | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
flowchart TD
A[Apply Quartz Powder] --> B[Flush Pan]
B --> C{Smudge Remaining?}
C -- No --> D[Pass Surface Finish Test]
C -- Yes --> E[Fail - Rework Required]
References:
IS 2556 Part 14: Performance Tests Key Points
| Description | Symbol | Dimension (mm) |
|---|---|---|
| Internal dia of outlet | d1 | 80 (Min) |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | 40 (Min) |
| Height of the bend | h | 207 |
| Description | Symbol | Dimension (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small) | W1 | 150 |
| Width of opening (wide) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100 ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Dimension (mm) |
|---|---|---|
| Depth of flush inlet socket | a | 25 (Min) |
| Distance from flush inlet socket end to outlet | b | 70 (Min) |
| Internal dia of outlet | d1 | 80 (Min) |
| External |
IS 2556 Part 14: Sampling, Process Inspection & Lot Inspection
| Parameter | Symbol | Value |
|---|---|---|
| Length | L | 500 mm |
| Overall length, Max | L1 | 730 mm |
| Length of opening | L2 | 430 mm |
| Width of opening (small end) | W1 | 150 mm |
| Width of opening (wide end) | W2 | 230 mm |
| Height | h1 | 320 ± 10 mm |
| Slope of bottom of pan | z | 100 ± 3° |
| Depth of water seal, Min | T | 50 mm |
| Parameter | Symbol | Value |
|---|---|---|
| Internal dia of outlet | d1 | ≥ 80 mm |
| External dia of outlet | d2 | 102 ± 5 mm |
| Internal dia of inlet socket | d5 | 115 mm |
| Depth of inlet socket | f | ≥ 40 mm |
| Height of bend | h | 207 mm |
flowchart TD
A[Sampling] --> B[Process Inspection]
B --> C[Lot Inspection]
C --> D[IS 9140:199
Clause 10.2 BIS Certification Marking:
| Aspect | Details |
|---|---|
| Governing Law | Bureau of Indian Standards Act, 1986 |
| Licensing Authority | Bureau of Indian Standards (BIS) |
| Applicability | Manufacturers/Producers of sanitary appliances |
| Marking Requirement | Each product may bear the BIS Standard Mark |
| Purpose | Ensures conformity to IS standards |
flowchart LR
A[Manufacturer] --> B[Apply for BIS License]
B --> C[Compliance Verification]
C --> D{License Granted?}
D -->|Yes| E[Use BIS Standard Mark on Product]
D -->|No| F[No Marking Allowed]
This marking system assures users of product quality and adherence to Indian standards.
Committee Composition (Annex A):
| Description | Symbol | Value (mm) |
|---|---|---|
| Length | L | 500 |
| Overall length, Max | L1 | 730 |
| Length of opening | L2 | 430 |
| Width of opening (small end) | W1 | 150 |
| Width of opening (wide end) | W2 | 230 |
| Height | h1 | 320 ± 10 |
| Slope of bottom of pan | z | 100° ± 3° |
| Depth of water seal, Min | T | 50 |
| Description | Symbol | Value (mm) |
|---|---|---|
| Internal dia of outlet | d1 | 80 (Min) |
| External dia of outlet | d2 | 102 ± 5 |
| Internal dia of inlet socket | d5 | 115 |
| Depth of inlet socket | f | 40 (Min) |
| Height of the bend | h | 207 |
graph TD
A[IS 2556 Part 14]
Frequently Asked
Under IS 2556 Part 14, the functional and connecting dimensions for integrated squatting pans are specified to ensure proper plumbing fit and performance.
| Description | Symbol | Dimension (mm) |
|---|---|---|
| Depth of flush inlet socket | a | ≥ 25 |
| Distance from end of flush inlet socket to outlet | b | ≥ 70 |
| Internal diameter of outlet (oval allowed) | d1 | ≥ 80 |
| External diameter of outlet (oval allowed) | d2 | 102 ± 5 |
| Internal diameter of flush inlet socket | d3 | 50 ± 3 |
| Length of serrated part of outlet | m | ≥ 40 |
| Distance from bottom of pan to outlet center | h | 140 |
| Angle of outlet with vertical plane | e1 | 104° |
Loading diagram...
This ensures the squatting pan fits standard plumbing connections and performs efficiently.
To comply with IS 2556 Part 14 for integrated squatting pans, the following test requirements apply:
General tests: As per IS 2556 (Part 1):1994, covering:
Specific tests for integrated squatting pans:
| Test Aspect | Reference Clause/Standard |
|---|---|
| Material & Manufacture | IS 2556 (Part 1):1994 |
| Glazing & Finish | IS 2556 (Part 1):1994 |
| Dimensional Tolerances | IS 2556 Part 14 (Clause 5) |
| Water Seal Depth | ≥ 50 mm (Clause 4.2) |
| Sampling & Inspection | IS 9140 : 1995 |
Ensure rounding off test results follows IS 2:1960 rules.
This integrated approach ensures durability, functionality, and plumbing compatibility.
IS 2556 Part 14 refers to glazing and surface finish requirements by referencing IS 2556 Part 1 (1994), which covers general requirements for vitreous china sanitary appliances.
Key points on glazing and surface finish:
| Test Aspect | Requirement |
|---|---|
| Smudge Material | Quartz powder, contrasting color |
| Particle Size | Passes 1.18 mm IS sieve |
| Smudge Depth | Up to 40 mm below flushing rim |
| Post-flush Condition | No smudge residue visible |
This ensures the pan's interior surface is properly glazed and finished for sanitary use.
According to IS 2556 Part 14:
Loading diagram...
This ensures hygienic, efficient flushing and odor prevention.
According to IS 2556 Part 14 (1995), Clause 10:
Each squatting pan must be clearly and indelibly marked at a suitable place with:
Additionally, each piece may be marked with the BIS Standard Mark (Clause 10.2.1).
| Marking Element | Requirement |
|---|---|
| Manufacturer's Name/Trade-mark | Mandatory |
| Batch/Lot Number | Mandatory |
| BIS Standard Mark | Optional but governed by BIS licence |
This ensures traceability and quality assurance of sanitary appliances under the standard.
Ask AI about any clause, requirement, or provision in IS 2556 Part 14. Get instant, clause-cited responses powered by our indexed library.
Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required