IS 2097:2012 specifies the requirements for foam making branch pipes and foam inductors used in fire fighting, particularly for producing mechanical foam to combat flammable liquid fires and spills. It covers three types of foam branches (FB 5X, FB 10X, FB 20X) based on flow capacity and outlines performance, material, design, marking, and testing criteria. This standard is essential for manufacturers, fire safety engineers, and emergency responders involved in foam-based fire suppression systems.
Overview
IS 2097:2012 specifies the requirements for foam making branch pipes and foam inductors used in fire fighting, particularly for producing mechanical foam to combat flammable liquid fires and spills. It covers three types of foam branches (FB 5X, FB 10X, FB 20X) based on flow capacity and outlines performance, material, design, marking, and testing criteria. This standard is essential for manufacturers, fire safety engineers, and emergency responders involved in foam-based fire suppression systems.
Audience
Contents
Structure
IS 2097: Scope & Key Specifications
| Parameter | Specification/Reference |
|---|---|
| Foam Branch Pipe Type | As per IS 2097 Table 1 |
| Foam Inductor Capacity | Given in Table 1 |
| Rounding Off Rules | IS 2:1960 (Rules for rounding numerical values) |
| Related Standards | Listed in Annex A (check for latest versions) |
If you need specific formulas or detailed tables (like discharge capacities or dimensions), please specify, and I can provide those accordingly.
IS 2097 References Summary:
Referenced IS Standards (Annex A) include specifications for materials related to fire fighting equipment, e.g.:
Rounding Off Rules: As per IS 2:1960, results must be rounded to the same number of significant digits as specified values.
Certification Marking: Governed by BIS Act, 1986 (Clause 7.2.1).
| IS No. | Title |
|---|---|
| 318:1981 | Leaded tin bronze ingots and castings |
| 410:1977 | Cold rolled brass sheet, strip and foil |
| 617:1994 | Aluminium and aluminium alloy ingots and castings |
| 3444:1999 | Corrosion resistant alloy steel and nickel base castings |
| 4989:2006 | Foam concentrate for producing mechanical foam |
| 7882:1975 | Aluminium sheet and strip for aircraft purposes |
graph LR
A[IS 2097 Standard] --> B[Material Specifications (Annex A)]
B --> C[IS 318, 410, 617, 3444, 4989, 7882]
A --> D[Rounding Rules (IS 2:1960)]
A --> E[BIS Certification Marking (Clause 7.2.1)]
This ensures compliance with material quality, testing accuracy, and certification.
IS 2097: Terminology & Key Specifications
Foam Making Branch Types (by flow capacity):
Rounding Off Rules:
Follow IS 2:1960 for rounding numerical results.
Table 1 (Capacities):
Defines flow capacities for foam branches (refer to IS 2097 Table 1 for exact values).
Standards Referenced:
Annex A lists related standards; always check for the latest editions.
| Foam Branch Type | Flow Capacity (lpm) |
|---|---|
| FB 5X | 225 |
| FB 10X | 450 |
| FB 20X | 900 |
This ensures uniform terminology and performance criteria for foam making branches in firefighting systems.
IS 2097: Foam Making Branches - Key Specifications & Design
IS 2097 specifies foam making branches in three types based on flow capacity:
| Type | Flow Capacity (lpm) | Description |
|---|---|---|
| FB 5X | 225 | Low flow foam branch |
| FB 10X | 450 | Medium flow foam branch |
| FB 20X | 900 | High flow foam branch |
flowchart LR
Water --> FoamBranch[Foam Making Branch (FB 5X/10X/20X)]
FoamConcentrate --> FoamBranch
FoamBranch --> FoamDischarge[Foam Discharge]
FoamBranch --> AirAspiration[Air Aspiration Ports]
For detailed dimensional drawings and performance tables, refer to IS 2097 figures and annexures.
IS 2097 covers foam making branch pipes and foam inductors with materials specified for durability and performance in fire fighting.
| Material Type | IS Code | Description |
|---|---|---|
| Leaded Tin Bronze Ingots & Castings | IS 318:1981 | For corrosion-resistant bronze components |
| Cold Rolled Brass Sheet, Strip & Foil | IS 410:1977 | For brass components requiring formability |
| Aluminium & Aluminium Alloy Ingots & Castings | IS 617:1994 | For lightweight, corrosion-resistant parts |
| Corrosion Resistant Alloy Steel & Nickel Base Castings | IS 3444:1999 | For high-strength, corrosion-resistant parts |
| Aluminium Sheet & Strip for Aircraft Purposes | IS 7882:1975 | High-grade aluminium alloys (Alloy 19000) |
| Material | Density (kg/m³) | Corrosion Resistance | Typical Use |
|---|---|---|---|
| Leaded Tin Bronze | ~8800 | Excellent | Branch pipe bodies, fittings |
| Brass (Cold Rolled) | ~8500 | Good | Thin sheets, foils |
| Aluminium Alloy | ~2700 | Very Good | Lightweight components |
| Alloy Steel Castings | ~7800 | Excellent | Structural parts |
flowchart LR
A[Materials of Construction] --> B[Bronze (IS 318)]
A --> C[Brass (IS 410)]
A --> D[Aluminium Alloy (IS 617)]
A --> E[Alloy Steel (IS 3444)]
B --> F[Corrosion Resistant Components]
C --> G[Formed Parts]
D --> H[Lightweight Components]
E --> I[High Strength Parts]
**Use these IS codes and material guidelines for selecting construction materials for foam making branch pipes and
IS 2097: Performance Requirements Summary
Foam Quality Testing (Clause 6.2):
Rounding Off (General Clause):
Capacities (Table 1):
| Parameter | Specification |
|---|---|
| Foam Drainage Time | Tested at 25% drainage (IS 4989) |
| Foam Stability | Within limits of Fig. 2 (IS 2097) |
| Rounding Off | As per IS 2:1960 rules |
| Capacities | As per Table 1 (refer IS 2097) |
flowchart LR
A[Foam Production] --> B[25% Drainage Time Test (IS 4989)]
B --> C{Meets Limits in Fig. 2?}
C -->|Yes| D[Pass Performance Requirements]
C -->|No| E[Fail - Adjust Foam Parameters]
For exact values and detailed limits, please refer to IS 2097 Table 1 and Fig. 2.
Clause 7.1: Mandatory Marking
Foam making branches shall be permanently marked with:
Clause 7.2: BIS Certification Marking
| Marking Item | Description |
|---|---|
| Manufacturer's Name | Clear, permanent identification |
| Type of Branch | Specify foam branch type |
| Flow Capacity | At rated pressure (e.g., L/min) |
| Year of Manufacture | Four-digit year |
| BIS Standard Mark | Optional, subject to BIS license |
flowchart TD
A[Foam Making Branch] --> B[Marking]
B --> C[Manufacturer Name/Trade Mark]
B --> D[Type of Branch]
B --> E[Flow Capacity at Rated Pressure]
B --> F[Year of Manufacture]
B --> G{BIS Certification Mark?}
G -->|Yes| H[Standard Mark with License]
G -->|No| I[No Standard Mark]
This ensures traceability, quality assurance, and compliance with IS 2097.
IS 2097 - Testing Methods Summary
Rounding Off (IS 2:1960):
Final test results must be rounded to the same number of significant figures as the specified values in IS 2097.
Foam Testing (Clause 6.2):
Capacities:
Refer to Table 1 in IS 2097 for standard capacities (e.g., load, pressure ratings).
Referenced Standards:
Annex A lists related standards (e.g., IS 4989 for foam testing) which are integral to compliance.
[ \text{Drainage Time} = \text{Time taken for 25% liquid to drain from foam} ]
Measured by collecting drained liquid volume over time until 25% volume is reached.
| Parameter | Acceptable Range |
|---|---|
| 25% Drainage Time | e.g., 90 - 150 sec |
| Foam Density | Specified per foam type |
| Stability Index | As per IS 4989 |
flowchart TD
A[Foam Production] --> B[Test for 25% Drainage Time (IS 4989)]
B --> C{Drainage Time within limits?}
C -- Yes --> D[Accept Foam Quality]
C -- No --> E[Reject/Adjust Foam]
Note: Always consult the latest edition of IS 2097 and referenced standards for precise values.
Clause 7.2 - BIS Certification Marking:
| IS No. | Title |
|---|---|
| 7882:75 | Foam concentrate for producing mechanical foam |
| 4989:06 | Specification for foam concentrate for firefighting |
| 410:77 | Cold rolled brass sheet, strip, and foil |
| 318:81 | Leaded tin bronze ingots and castings |
flowchart TD
A[Manufacturer Applies for License] --> B[BIS Evaluation]
B --> C{Compliance with IS 2097?}
C -- Yes --> D[License Granted]
C -- No --> E[Rectify & Reapply]
D --> F[Use of BIS Standard Mark]
For detailed licensing conditions, contact Bureau of Indian Standards (BIS), Manak Bhavan, New Delhi.
IS 2097: Operation and Handling - Key Points
Rounding Off Values:
Follow IS 2:1960 for rounding numerical results in tests or analysis.
Design Flexibility:
Various designs (see Fig. 1B) are indicative only.
Capacities:
Refer to Table 1 for capacities of different types (not provided here).
| Parameter | FB 10X | FB 20X |
|---|---|---|
| Operation Type | Single operator | Two operators |
| Capacity Range | As per Table 1 | As per Table 1 |
| Holding Arrangement | Standard | Facilitates two operators |
flowchart LR
A[Start Operation] --> B{Design Type}
B -->|FB 10X| C[Single Operator Handling]
B -->|FB 20X| D[Two Operator Handling]
C --> E[Check Capacity from Table 1]
D --> E
E --> F[Apply Force F = P × A]
F --> G[Operation Successful]
Note: For exact values and detailed capacities, always refer to Table 1 and Fig. 1B in IS 2097.
IS 2097 references essential Indian Standards related to materials and fire-fighting foam concentrates:
| IS No. | Title |
|---|---|
| IS 318:1981 | Specification for leaded tin bronze ingots and castings (2nd revision) |
| IS 410:1977 | Specification for cold rolled brass sheet, strip and foil (3rd revision) |
| IS 617:1994 | Aluminium and aluminium alloy ingots and castings for general engineering purposes (3rd) |
| IS 3444:1999 | Corrosion resistant alloy steel and nickel base castings for general application (3rd) |
| IS 4989:2006 | Foam concentrate for producing mechanical foam for fire fighting (3rd revision) |
| IS 7882:1975 | Specification for aluminium sheet and strip for aircraft purposes (Alloy 19000) |
This table aids in cross-referencing materials and foam concentrate standards critical for fire-fighting equipment design and testing per IS 2097.
Reference:
| Organization | Representative(s) |
|---|---|
| Ministry of Home Affairs, New Delhi | Shri Om Prakash (Chairman), Shri D. K. Shami (Alternate) |
| Agni Controls, Chennai | Shri D. Balachandran |
| Airport Authority of India, New Delhi | Shri Subhash Kumar, Shri R. Banerjee (Alternate) |
| Bhabha Atomic Research Centre, Mumbai | Chief Fire Officer |
| Bombay Fire Brigade, Mumbai | Chief Fire Officer, Deputy Chief Fire Officer (Alternate) |
| Central Building Research Institute, Roorkee | Dr. M. P. Singh, Shri Suvir Singh (Alternate) |
| Defence Research Development Organization, Ministry of Defence, Delhi | Shrimati Meenakshi Gupta, Shri B. C. Sharma (Alternate) |
| Fire Protection Association of India, Mumbai | President |
...and many other government, industry, and research representatives.
graph TD
A[Fire Fighting Sectional Committee, CED 22]
A --> B[Government Ministries]
A --> C[Research Institutes]
A --> D[Industry Representatives]
A --> E[Fire Services]
A --> F[Safety & Standards Bodies]
B --> B1[Ministry of Home Affairs]
C --> C1[CBRI Roorkee]
D --> D1[Agni Controls]
E --> E1[Bombay Fire Brigade]
F --> F1[Fire Protection Association of India]
For full details, refer to Annex B of IS 2097.
Frequently Asked
IS 2097: Flow Capacities for Foam Making Branches
According to IS 2097, foam making branches are classified by their flow capacities as follows:
| Type of Foam Branch | Flow Capacity (liters per minute, lpm) |
|---|---|
| FB 5X | 225 lpm |
| FB 10X | 450 lpm |
| FB 20X | 900 lpm |
Foam making branches are essential for producing mechanical foam to fight flammable liquid fires and cover spills.
Loading diagram...
This ensures proper foam generation for effective fire control.
IS 2097 does not explicitly list the permitted materials for foam making branches and foam inductors in the provided context. However, based on standard fire-fighting equipment practices and IS norms:
For exact material grades and specifications, refer to the detailed clauses in IS 2097 or related standards on firefighting equipment materials.
According to IS 2097 (2012), the performance of foam making branches is evaluated primarily by the foam quality and drainage time:
Foam production is tested for 25% drainage time as per IS 4989. This measures how long it takes for 25% of the liquid in the foam to drain out, indicating foam stability.
The mechanical foam qualities (like expansion ratio and drainage time) must fall within limits specified in Fig. 2 of IS 2097, ensuring effective foam generation.
Foam making branches are classified by flow capacity:
Summary:
| Parameter | Requirement |
|---|---|
| Foam drainage time | 25% drainage time per IS 4989 |
| Foam quality limits | Within Fig. 2 limits of IS 2097 |
| Flow capacities | FB 5X (225 lpm), FB 10X (450 lpm), FB 20X (900 lpm) |
This ensures foam branches produce stable, high-quality foam suitable for firefighting.
According to IS 2097 Clause 7.1, foam making branches must be clearly and permanently marked with:
Additionally, per Clause 7.2, the foam making branches may bear the BIS Standard Mark indicating certification compliance.
| Marking Information | Details |
|---|---|
| Manufacturer/Trade-mark | Name or logo |
| Branch Type | FB 5X / FB 10X / FB 20X |
| Flow Capacity | 225 / 450 / 900 liters per min |
| Year of Manufacture | Four-digit year |
| BIS Certification Mark | Optional Standard Mark |
This ensures traceability, performance identification, and quality assurance for firefighting equipment.
IS 2097 ensures compatibility with various foam concentrates primarily through performance-oriented design and material specifications:
This approach ensures that foam branches and inductors perform reliably with various foam concentrates used in firefighting operations.
Loading diagram...
Ask AI about any clause, requirement, or provision in IS 2097. Get instant, clause-cited responses powered by our indexed library.
Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required