IS 1626 Part 2:1994 specifies the requirements for asbestos cement gutters and gutter fittings used in building construction for effective rainwater disposal. It covers material composition, dimensional tolerances, physical properties, sampling, testing methods including impermeability, and marking requirements. This standard is essential for manufacturers, quality controllers, and engineers involved in the production, specification, and installation of asbestos cement rainwater drainage systems.
Overview
IS 1626 Part 2:1994 specifies the requirements for asbestos cement gutters and gutter fittings used in building construction for effective rainwater disposal. It covers material composition, dimensional tolerances, physical properties, sampling, testing methods including impermeability, and marking requirements. This standard is essential for manufacturers, quality controllers, and engineers involved in the production, specification, and installation of asbestos cement rainwater drainage systems.
Audience
Contents
Structure
IS 1626 Part 2 - Scope Summary & Key Specifications
| Gutter Type | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| Valley Gutter | 915×205×230 | 915 | 205 | 230 | 12.5 |
| 610×150×230 | 610 | 150 | 230 | 12.5 | |
| 455×125×150 | 455 | 125 | 150 | 12.5 | |
| 405×125×255 | 405 | 125 | 255 | 12.5 |
| Gutter Type | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| Boundary Wall | 510×150×255 | 510 | 150 | 255 | 12.5 |
| 455×150×305 | 455 | 150 | 305 | 12.5 | |
| 305×150×230 | 305 | 150 | 230 | 12.5 | |
| 280×125×180 | 280 | 125 | 180 | 12.5 |
| Gutter Type | Nominal Size (Diameter) | A | c | S (Thickness) |
|---|---|---|---|---|
| Half Round | 305 | 305 | 95 | 100 |
| 230 | 230 | 95 | 100 | |
| 150 | 150 | 9.5 | 70 |
| Lot Size | Sample Size |
|---|---|
IS 1626 Part 2: Key References, Tables & Specifications for Asbestos Cement Gutters
| Item | Code No. | Figure No. | Table No. |
|---|---|---|---|
| Valley gutter | V | 1 | 2 |
| Boundary wall gutter | BW | 2 | 3 |
| Half round gutter | H | 3 | 4 |
Table 2: Valley Gutter
| Nominal Size (L×W×H) | A | B | C | D |
|---|---|---|---|---|
| 915 × 205 × 230 | 915 | 205 | 230 | 12.5 |
| 610 × 150 × 230 | 610 | 150 | 230 | 12.5 |
| 455 × 125 × 150 | 455 | 125 | 150 | 12.5 |
| 405 × 125 × 255 | 405 | 125 | 255 | 12.5 |
Table 3: Boundary Wall Gutter
| Nominal Size (L×W×H) | A | B | C | D |
|---|---|---|---|---|
| 510 × 150 × 255 | 510 | 150 | 255 | 12.5 |
| 455 × 150 × 305 | 455 | 150 | 305 | 12.5 |
| 305 × 150 × 230 | 305 | 150 | 230 | 12.5 |
| 280 × 125 × 180 | 280 | 125 |
IS 1626 Part 2: Definitions & Dimensional Specifications for Asbestos Cement Gutters
| Gutter Type | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| Valley Gutter | 915×205×230 | 915 | 205 | 230 | 12.5 |
| 610×150×230 | 610 | 150 | 230 | 12.5 | |
| 455×125×150 | 455 | 125 | 150 | 12.5 | |
| 405×125×255 | 405 | 125 | 255 | 12.5 |
| Boundary Wall Gutter | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| 510×150×255 | 510 | 150 | 255 | 12.5 | |
| 455×150×305 | 455 | 150 | 305 | 12.5 | |
| 305×150×230 | 305 | 150 | 230 | 12.5 | |
| 280×125×180 | 280 | 125 | 180 | 12.5 |
| Half Round Gutter | Nominal Size (Diameter) | A | c | S (Thickness) |
|---|---|---|---|---|
| 305 | 305 | 95 | 100 | |
| 230 | 230 | 95 | 100 |
IS 1626 Part 2: General Quality and Workmanship - Key Specifications
| Gutter Type | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| Valley Gutter (Table 2) | 915×205×230 | 915 | 205 | 230 | 12.5 |
| 610×150×230 | 610 | 150 | 230 | 12.5 | |
| 455×125×150 | 455 | 125 | 150 | 12.5 | |
| 405×125×255 | 405 | 125 | 255 | 12.5 |
| Gutter Type | Nominal Size (L×W×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|---|
| Boundary Wall Gutter (Table 3) | 510×150×255 | 510 | 150 | 255 | 12.5 |
| 455×150×305 | 455 | 150 | 305 | 12.5 | |
| 305×150×230 | 305 | 150 | 230 | 12.5 | |
| 280×125×180 | 280 | 125 | 180 | 12.5 |
| Gutter Type | Nominal Size (Diameter) | A | c (Depth) | S (Thickness) |
|---|---|---|---|---|
| Half Round Gutter (Table 4) | 305 | 305 | 95 | 100 |
| 230 | 230 | 95 | 100 | |
| 150 | 150 | 95 | 70 |
IS 1626 Part 2: Dimensional and Physical Requirements for Asbestos Cement Gutters
Dimensions and tolerances for gutters per Figures 1-3 and Tables 1-4.
| Item | Code | Figure No. | Table No. |
|---|---|---|---|
| Valley gutter | V | 1 | 2 |
| Boundary wall gutter | BW | 2 | 3 |
| Half round gutter | H | 3 | 4 |
| Nominal Size (L×B×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|
| 915×205×230 | 915 | 205 | 230 | 12.5 |
| 610×150×230 | 610 | 150 | 230 | 12.5 |
| 455×125×150 | 455 | 125 | 150 | 12.5 |
| 405×125×255 | 405 | 125 | 255 | 12.5 |
| Nominal Size (L×B×H) | A | B | C | D (Thickness) |
|---|---|---|---|---|
| 510×150×255 | 510 | 150 | 255 | 12.5 |
| 455×150×305 | 455 | 150 | 305 | 12.5 |
| 305×150×230 | 305 | 150 | 230 | 12.5 |
| 280×125×180 | 280 | 125 | 180 | 12.5 |
| Nominal Size (Diameter) | A | C (Radius) | S (Thickness) |
|---|---|---|---|
| 305 | 305 | 95 | 100 |
| 230 |
IS 1626 Part 2: Sampling and Number of Tests
Sampling is done by selecting gutters randomly from a lot based on lot size:
| Lot Size | Sample Size |
|---|---|
| Up to 500 | 3 |
| 501 to 1,000 | 5 |
| 1,001 to 1,500 | 7 |
| 1,501 and above | 10 |
This ensures statistically valid sampling and reliable quality control for gutters under IS 1626 Part 2.
Manufacturer's Certificate - IS 1626 (Part 2):1994
| Gutter Type | Nominal Size (mm) | A | B | C | D |
|---|---|---|---|---|---|
| Valley Gutter | 915 × 205 × 230 | 915 | 205 | 230 | 12.5 |
| Boundary Wall Gutter | 510 × 150 × 255 | 510 | 150 | 255 | 12.5 |
| Half Round Gutter | 305 | 305 | 95 | 100 | - |
flowchart TD
A[Manufacturing] --> B[Dimensional Checks]
B --> C[Visual & Impermeability Tests]
C --> D{Conforms to IS 1626?}
D -- Yes --> E[Issue Manufacturer's Certificate]
D -- No --> F[Reject/Rectify Product]
E --> G[Supply with Safety Rules Sheet]
This ensures traceability and quality assurance per IS 1626 (Part 2).
IS 1626 Part 2: Marking and Labeling Key Points
8.1 Gutter & Fittings Marking:
8.2 BIS Certification Mark:
| Item | Code | Figure No. | Table No. |
|---|---|---|---|
| Valley Gutter | V | 1 | 2 |
| Boundary Wall Gutter | BW | 2 | 3 |
| Half Round Gutter | H | 3 | 4 |
Table 2: Valley Gutter
| Nominal Size (L×B×H) | A | B | C | D |
|---|---|---|---|---|
| 915×205×230 | 915 | 205 | 230 | 12.5 |
| 610×150×230 | 610 | 150 | 230 | 12.5 |
| 455×125×150 | 455 | 125 | 150 | 12.5 |
| 405×125×255 | 405 | 125 | 255 | 12.5 |
Table 3: Boundary Wall Gutter
| Nominal Size (L×B×H) | A | B | C | D |
|---|---|---|---|---|
| 510×150×255 | 510 | 150 | 255 | 12.5 |
| 455×150×305 | 455 | 150 | 305 | 12.5 |
| 305×150×230 | 305 | 150 | 230 | 12.5 |
| 280×125×180 | 280 | 125 | 180 | 12.5 |
Table 4: Half Round Gutter
| Nominal Size (Diameter
IS 1626 Part 2: Safety Rules Sheet - Key Specifications & Tables
| Item Type | Code | Figure No. | Table No. |
|---|---|---|---|
| Valley gutter | V | 1 | 2 |
| Boundary wall gutter | BW | 2 | 3 |
| Half round gutter | H | 3 | 4 |
| Valley Gutter (Table 2) | A | B | C | D |
|---|---|---|---|---|
| 915 × 205 × 230 | 915 | 205 | 230 | 12.5 |
| 610 × 150 × 230 | 610 | 150 | 230 | 12.5 |
| 455 × 125 × 150 | 455 | 125 | 150 | 12.5 |
| 405 × 125 × 255 | 405 | 125 | 255 | 12.5 |
| Boundary Wall Gutter (Table 3) | A | B | C | D |
|---|---|---|---|---|
| 510 × 150 × 255 | 510 | 150 | 255 | 12.5 |
| 455 × 150 × 305 | 455 | 150 | 305 | 12.5 |
| 305 × 150 × 230 | 305 | 150 | 230 | 12.5 |
| 280 × 125 × 180 | 280 | 125 | 180 | 12.5 |
| Half Round Gutter (Table 4) | A | C | S |
|---|
IS 1626 Part 2: Key Tables & Specifications Summary
| SI No. | Item Description | Code | Figure No. | Table No. |
|---|---|---|---|---|
| i) | Valley gutter | V | 1 | 2 |
| ii) | Boundary wall gutter | BW | 2 | 3 |
| iii) | Half round gutter | H | 3 | 4 |
| Nominal Size (L×W×H) | A | B | C | D |
|---|---|---|---|---|
| 915 × 205 × 230 | 915 | 205 | 230 | 12.5 |
| 610 × 150 × 230 | 610 | 150 | 230 | 12.5 |
| 455 × 125 × 150 | 455 | 125 | 150 | 12.5 |
| 405 × 125 × 255 | 405 | 125 | 255 | 12.5 |
| Nominal Size (L×W×H) | A | B | C | D |
|---|---|---|---|---|
| 510 × 150 × 255 | 510 | 150 | 255 | 12.5 |
| 455 × 150 × 305 | 455 | 150 | 305 | 12.5 |
| 305 × 150 × 230 | 305 | 150 | 230 | 12.5 |
| 280 × 125 × 180 | 280 | 125 | 180 | 12.5 |
| Nominal Size (Diameter) | A | c | S
| Role | Representative Organizations |
|---|---|
| Chairman | Dr. H. C. Visvesvaraya |
| Members | Cement companies, Research institutes, Govt. bodies, Industry associations |
| Member Secretary | Director General, BIS |
graph LR
A[Chairman: Dr. H.C. Visvesvaraya] --> B[Members]
B --> C[Cement Manufacturers]
B --> D[Research Institutes]
B --> E[Government Departments]
B --> F[Industry Associations]
B --> G[Engineering Consultants]
B --> H[Testing & Standards Bodies]
A --> I[Member Secretary: Shri Y.R. Taneja]
This structure ensures balanced inputs for the development of IS 1626 standards.
Frequently Asked
Materials and Cement Types for Asbestos Cement Gutters (IS 1626 Part 2):
Aggregate: Clean, inert asbestos fibers and suitable other fibers.
Cement: One of the following types conforming to respective IS codes:
Additives: Pozzolanic materials, fillers, and pigments compatible with asbestos cement may be added.
Additional Requirements:
This ensures durability, lightness, and suitability for rainwater disposal in buildings.
Dimensional Tolerances for Gutters and Gutter Fittings as per IS 1626 Part 2:
Additional Notes:
Loading diagram...
These tolerances ensure proper fit and function of gutters and fittings in construction.
Impermeability Test for Asbestos Cement Gutters (IS 1626 Part 2)
| Parameter | Requirement |
|---|---|
| Test Duration | 24 hours |
| Test Method | IS 5913:1989 Method 1 |
| Specimen | Any suitable place on the gutter |
| Impermeability Criteria | No water drops; only traces of moisture allowed |
Loading diagram...
This ensures gutters are watertight and durable in service.
According to IS 1626 Part 2, Clause 8.1, all gutters and gutter fittings must be clearly and indelibly marked with:
Additional notes:
This marking ensures traceability, compatibility, and safety compliance.
To ensure lot conformity as per IS 1626 Part 2, follow these steps:
| Lot Size | Sample Size |
|---|---|
| Up to 500 | 3 |
| 501 to 1,000 | 5 |
| 1,001 to 1,500 | 7 |
| 1,501 and above | 10 |
Loading diagram...
This ensures reliable quality control for gutter lots.