IS 15834 Part B (2008) specifies the requirements for stainless steel sliding door bolts designed for use with padlocks, focusing on materials, manufacturing, dimensions, finish, and performance. This standard is essential for engineers, manufacturers, and quality controllers involved in producing or specifying rust-resistant, durable sliding door bolts suitable for high-humidity environments such as coastal areas.
Overview
IS 15834 Part B (2008) specifies the requirements for stainless steel sliding door bolts designed for use with padlocks, focusing on materials, manufacturing, dimensions, finish, and performance. This standard is essential for engineers, manufacturers, and quality controllers involved in producing or specifying rust-resistant, durable sliding door bolts suitable for high-humidity environments such as coastal areas.
Audience
Contents
Structure
IS 15834 Part B: Scope - Key Specifications & Sampling
Sizes of Stainless Steel Sliding Door Bolts:
Sampling & Conformity Criteria (Clause 10.2, Table 1):
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
Material Compliance:
Manufacturer must provide a certificate confirming compliance with material requirements per Clause 4.
Referenced Standards:
flowchart TD
A[Lot of Sliding Door Bolts] --> B{Lot Size?}
B -->|<=200| C[Sample 5 bolts]
B -->|201-300| D[Sample 8 bolts]
B -->|301-500| E[Sample 13 bolts]
B -->|501-800| F[Sample 20 bolts]
B -->|>800| G[Sample 25 bolts]
C --> H{Defective Bolts?}
D --> H
E --> H
F --> H
G --> H
H -->|<= Allowed Defects| I[Lot Accepted]
H -->|> Allowed Defects| J[Lot Rejected]
This ensures quality control by limiting defective bolts based on lot size.
IS 15834 Part B - Key References and Specifications
| IS No. | Title |
|---|---|
| IS 1608:2005 | Metallic materials - Tensile testing at ambient temperature (3rd revision) |
| IS 6527:1995 | Stainless steel wire rods - Specification (1st revision) |
| IS 6911:1972 | Stainless steel plate, sheet and strip - Specification (1st revision) |
| Lot Size | Sample Size | Permissible Defective Bolts |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart TD
A[Lot Size] --> B[Sample Size]
B --> C[Inspection]
C --> D{Defective Bolts ≤ Permissible?}
D -->|Yes| E[Lot Accepted]
D -->|No| F[Lot Rejected]
This summarizes the key references and conformity criteria for IS 15834 Part B.
IS 15834 Part B: Material Requirements for Stainless Steel Sliding Door Bolts
| IS No. | Title |
|---|---|
| 1608:2005 | Metallic materials - Tensile testing at ambient temperature |
| 6527:1995 | Stainless steel wire rods - Specification |
| 6911:1972 | Stainless steel plate, sheet, and strip - Specification |
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart TD
A[Lot of Bolts] --> B{Lot Size}
B -->|≤200| C[Sample 5 bolts]
B -->|201-300| D[Sample 8 bolts]
B -->|301-500| E[Sample 13 bolts]
B -->|501-800| F[Sample 20 bolts]
B -->|>800| G[Sample 25 bolts]
C --> H{Defective bolts ≤ 0?}
D --> I{Defective bolts ≤ 1?}
E --> J{Defective bolts ≤ 2?}
F --> K{Defective bolts ≤ 2?}
G --> L{Defective bolts ≤ 3?}
H --> M[Accept Lot]
I --> M
J --> M
K -->
Clause 10.5: Certificate of Compliance
| Lot Size | Sample Size | Max Defective Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 – 300 | 8 | 1 |
| 301 – 500 | 13 | 2 |
| 501 – 800 | 20 | 2 |
| Above 801 | 25 | 3 |
flowchart TD
A[Manufacture Sliding Door Bolts] --> B{Material Compliance}
B -->|Yes| C[Certificate of Compliance]
B -->|No| D[Reject Lot]
C --> E{Sampling Test}
E -->|Pass| F[Accept Lot]
E -->|Fail| D
C --> G{Corrosion Test Required?}
G -->|Yes| H[Salt Spray Test 48h]
G -->|No| F
This ensures quality and conformity per IS 15834 Part B.
IS 15834 Part B: Dimensions and Tolerances for Sliding Door Bolts
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
graph LR
A[Bolt Diameter (D)] -->|12, 14, 16 mm| B[Thickness (t)]
B -->|2.20 mm (12/14 mm D)| C[Length: 200, 250, 300 mm]
B -->|2.50 mm (16 mm D)| C
C --> D[Smooth edges & corners]
Note: Refer to IS 15834 Fig. 1 for exact dimensional drawings and tolerances.
IS 15834 Part B: Marking and Packaging for Stainless Steel Sliding Door Bolts
Marking:
Packaging:
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart TD
A[Manufacture Stainless Steel Bolts] --> B[Mark with BIS Standard Mark]
B --> C[Pack Bolts in Cartons]
C --> D[Label Cartons with Manufacturer Info]
D --> E[Sampling & Quality Check per IS 15834]
E --> F{Accept Lot?}
F -->|Yes| G[Dispatch]
F -->|No| H[Reject/Rectify]
This ensures compliance with IS 15834 Part B for quality and traceability.
IS 15834 Part B — Sampling and Criteria for Conformity
| Lot Size (No. of bolts) | Sample Size (No. of bolts) | Permissible Defects (Max) |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 to 300 | 8 | 1 |
| 301 to 500 | 13 | 2 |
| 501 to 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart LR
A[Lot Size] --> B[Select Sample Size]
B --> C{Count Defective Bolts}
C -->|≤ Permissible Defects| D[Lot Accepted]
C -->|> Permissible Defects| E[Lot Rejected]
This method balances inspection effort and quality assurance per IS 15834 Part B.
IS 15834 Part B: Testing Requirements Summary
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart TD
A[Lot Size] --> B[Sample Size]
B --> C[Inspect bolts]
C --> D{Defective bolts ≤ Permissible?}
D -- Yes --> E[Lot Accepted]
D -- No --> F[Lot Rejected]
Use this sampling plan and testing protocol to ensure compliance with IS 15834 Part B.
1. Material Grades (Clause 4.1):
2. Corrosion Test (Clause 10.3.3):
3. Reference Standards (Clause 2.1):
| Parameter | Specification |
|---|---|
| Duration | 48 hours |
| Test Medium | Neutral Salt Spray (NSS) |
| Salt Concentration | 5% NaCl solution |
| Temperature | 35 ± 2 °C |
| Evaluation | No visible corrosion or pitting |
flowchart TD
A[Material Selection] --> B{Grade per IS 6911}
B -->|X07Cr18Ni9 or X10Cr17Mn6Ni4N20| C[Manufacture]
C --> D{Corrosion Test Required?}
D -->|Yes| E[Salt Spray Test - 48h]
D -->|No| F[Certificate of Compliance]
E --> G{Pass/Fail}
G -->|Pass| F
G -->|Fail| H[Review Material or Process]
Note: Always refer to purchaser agreements for specific test methods or criteria beyond IS defaults.
IS 15834 Part B: Quality Control & Inspection Key Points
| Lot Size | Sample Size | Max Defective Bolts Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 to 300 | 8 | 1 |
| 301 to 500 | 13 | 2 |
| 501 to 800 | 20 | 2 |
| 801 and above | 25 | 3 |
flowchart TD
A[Lot Size] --> B[Select Sample Size]
B --> C{Count Defective Bolts}
C -->|≤ Permissible| D[Lot Accepted]
C -->|> Permissible| E[Lot Rejected]
D --> F[Certificate of Compliance]
Use this table and criteria for quality control inspection of sliding door bolts as per IS 15834 Part B.
1. BIS Certification Marking (Clause 8.1.1 & 8.1.1.1):
2. Packaging and Labelling:
3. Conformity (Clause 10.5):
| Size (mm) |
|---|
| 200 |
| 250 |
| 300 |
flowchart LR
A[BIS Certification Mark] --> B[Manufacturer License]
B --> C[Marking on Product]
C --> D[Packaging with Label]
D --> E[Certificate of Compliance]
E --> F[Conformity to IS 15834]
Contact BIS for licensing:
This ensures standardized quality and traceability of stainless steel tower bolts.
Annex A lists the Builder's Hardware Sectional Committee (CED 15) members responsible for the standard formulation.
Committee Composition:
Representative Organizations:
Purpose:
Ensures balanced inputs from industry, research, government, and testing agencies for standard development.
| Lot Size | Sample Size | Max Defective Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 - 300 | 8 | 1 |
| 301 - 500 | 13 | 2 |
| 501 - 800 | 20 | 2 |
| 801 and above | 25 | 3 |
This committee composition ensures comprehensive stakeholder involvement in the standardization process.
Frequently Asked
IS 15834 Part B does not explicitly list stainless steel grades for sliding door bolts. However, it references related standards for stainless steel materials:
Common stainless steel grades used for sliding door bolts (based on these references and typical practice):
| Material Form | Typical Stainless Steel Grades |
|---|---|
| Wire Rods | SS 304, SS 316 |
| Plates/Sheets | SS 304, SS 316, SS 410 |
Recommendation: Use SS 304 or SS 316 for better corrosion resistance in sliding door bolts under IS 15834 Part B.
Loading diagram...
IS 15834 Part B ensures corrosion resistance for sliding door bolts primarily by:
| Aspect | Requirement |
|---|---|
| Material | Stainless steel (suitable grade) |
| Surface Finish | Polished bright, smooth surface |
| Quality Control | Defect-free, dimensionally accurate |
| Application | Suitable for humid/coastal areas |
This approach ensures durability, rust-proofing, and aesthetic quality for sliding door bolts in corrosive environments.
Dimensional Tolerances for Stainless Steel Sliding Door Bolts (IS 15834 Part B)
| Parameter | Tolerance (typical as per Fig. 1) |
|---|---|
| Bolt length | ±0.5 mm |
| Bolt diameter | ±0.2 mm |
| Sliding action fit | Smooth, no binding |
Note: Refer to Fig. 1 in IS 15834 Part B for exact dimensional values and tolerances. Quality control requires random sampling (minimum 10% packets, min 3 bolts per packet).
Loading diagram...
Conformity Assessment per IS 15834 Part b (Clauses 10.2, 10.4, 10.5):
| Lot Size | Sample Size | Max Defective Allowed |
|---|---|---|
| Up to 200 | 5 | 0 |
| 201 to 300 | 8 | 1 |
| 301 to 500 | 13 | 2 |
| 501 to 800 | 20 | 2 |
| Above 800 | 25 | 3 |
Summary:
Loading diagram...
This ensures systematic quality control aligned with IS 15834 Part b.
According to IS 15834 Part B, the marking and packaging requirements for stainless steel sliding door bolts are:
Marking:
Packaging:
Corrosion resistance testing:
This ensures traceability, quality assurance, and protection during transport.
Ask AI about any clause, requirement, or provision in IS 15834 Part b. Get instant, clause-cited responses powered by our indexed library.
Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required