IS 13074:1991 provides a comprehensive code of practice for laying bitumen mastic flooring specifically designed for industries handling LPG and other light hydrocarbon products. It outlines procedures for base preparation, application, and maintenance to ensure durable, jointless, and moisture-impervious flooring that withstands hydrocarbon exposure and industrial loads. This standard is essential for engineers and contractors involved in flooring solutions within hazardous industrial environments.
Overview
IS 13074:1991 provides a comprehensive code of practice for laying bitumen mastic flooring specifically designed for industries handling LPG and other light hydrocarbon products. It outlines procedures for base preparation, application, and maintenance to ensure durable, jointless, and moisture-impervious flooring that withstands hydrocarbon exposure and industrial loads. This standard is essential for engineers and contractors involved in flooring solutions within hazardous industrial environments.
Audience
Contents
Structure
IS 13074: Scope & Key Specifications
Scope:
IS 13074:1991 provides guidelines for the preparation of base, laying, and maintenance of bitumen mastic flooring, specifically for industries handling LPG and light hydrocarbons. It must be read alongside:
Key Points:
Related Standards:
| Standard | Purpose |
|---|---|
| IS 13026:1990 | Bitumen mastic flooring specification |
| IS 8374:1977 | Antistatic, electrically conducting bitumen mastic |
| IS 1196:1978 | Laying practice for bitumen mastic flooring |
This standard ensures safety, durability, and quality control under BIS supervision for LPG-related industrial flooring.
Primary referenced standards:
Key points:
| IS Code | Title | Purpose |
|---|---|---|
| IS 13026 | Bitumen mastic flooring for LPG/light hydrocarbons | Material specification |
| IS 8374 | Bitumen mastic, antistatic & electrically conducting | Material specification |
| IS 1196 | Code of practice for laying bitumen mastic flooring | Installation guidelines |
| IS 2 | Rules for rounding off numerical values | Standardized rounding of test results |
Note: For detailed formulas or design tables, refer to the respective IS codes mentioned above.
flowchart LR
A[IS 13074] --> B[IS 13026]
A --> C[IS 8374]
A --> D[IS 1196]
A --> E[IS 2]
B --> F[Material Spec for Bitumen Mastic]
C --> G[Antistatic & Conducting Grades]
D --> H[Laying Practices]
E --> I[Rounding Rules]
This diagram shows the relationship of IS 13074 with its referenced standards.
IS 13074: Design Considerations for Bitumen Mastic Flooring
IS 13074 primarily references related standards for design and installation:
| Aspect | IS Code | Description |
|---|---|---|
| Bitumen Mastic Specification | IS 13026:1990 | For LPG and hydrocarbon industries |
| Laying Procedure | IS 1196:1978 | Code of practice for laying bitumen mastic |
| Bitumen Grades | IS 8374:1977 | Antistatic and electrically conducting grades |
flowchart LR
A[Substrate Preparation] --> B[Bitumen Mastic Application]
B --> C[Thickness Control (3-6 mm)]
C --> D[Surface Finishing]
D --> E[Maintenance]
E --> F[Periodic Cleaning & Spill Removal]
Note: Always verify the latest amendments and cross-reference IS 2:1960 for rounding test values.
Thickness of Bitumen Mastic Flooring (IS 13074)
Total Thickness:
As per Clause 4.1, the bitumen mastic flooring thickness should be 20 mm to 25 mm, or as mutually agreed based on site conditions.
Laying Method (Clause 7.3.2):
Design Considerations (Clause 3.1):
| Parameter | Specification |
|---|---|
| Thickness | 20 mm to 25 mm |
| Layers | One or more |
| Surface Finish Tools | Gauges, straight edges, band levels |
| Design Reference | IS 13026:1990 for hydrocarbon service |
flowchart TD
A[Start: Flooring Design] --> B{Service Conditions?}
B -->|Hydrocarbon| C[Refer IS 13026:1990]
B -->|Others| D[Standard Thickness 20-25 mm]
C --> E[Decide Thickness & Layers]
D --> E
E --> F[Lay Bitumen Mastic in Bays]
F --> G[Maintain Thickness with Tools]
G --> H[Finished Flooring - Jointless & Moisture Impervious]
This ensures compliance with IS 13074 and related standards for safe, durable bitumen mastic flooring.
IS 13074: Materials for Bitumen Mastic Flooring
Relevant Standards:
Material Specifications:
Testing and Quality Control:
Rounding Off:
| Material | Standard Code | Key Property Focus |
|---|---|---|
| Bitumen Mastic | IS 13026:1990 | Chemical composition, durability |
| Antistatic Grade | IS 8374:1977 | Electrical conductivity, safety |
| Laying Practice | IS 1196:1978 | Application procedures |
flowchart LR
A[Bitumen Mastic Flooring] --> B[Material: Bitumen Mastic]
B --> C[IS 13026:1990 Compliance]
B --> D[Antistatic/Electrical Grade per IS 8374]
A --> E[Laying Practice]
E --> F[IS 1196:1978]
A --> G[Maintenance]
G --> H[Cleaning with water & detergent]
G --> I[Immediate spill removal]
For detailed physical and chemical properties, refer directly to IS 13026:1990.
IS 13074: Equipment Specifications for Bitumen Mastic Flooring
| Equipment | Purpose | Key Requirement |
|---|---|---|
| Bitumen Boiler | Heat bitumen to molten state | Maintain temperature near site |
| Mechanically Agitated Cooker | Mix bitumen and fillers uniformly | Continuous agitation |
| Accessories | Application & maintenance | Suitable for site conditions |
flowchart LR
A[Bitumen Boiler] --> B[Molten Bitumen]
B --> C[Agitated Mastic Cooker]
C --> D[Uniform Bitumen Mastic]
D --> E[Application Near Site]
Note: Always consult IS 13026 for detailed material and equipment specifications related to bitumen mastic flooring.
IS 13074: Laying Procedure for Bitumen Mastic Flooring
Spreading:
Bubble Handling:
| Layer Type | Typical Thickness (mm) |
|---|---|
| Single Layer | 3 to 5 |
| Multiple Layers | Total as per design |
Use suitable gauges and straight edges to maintain uniform thickness.
flowchart TD
A[Start Laying] --> B[Spread Bitumen Mastic in Bays]
B --> C[Maintain Thickness using Gauges]
C --> D{Bubbles Formed?}
D -- Yes --> E[Puncture Bubbles While Hot]
D -- No --> F[Continue Spreading]
E --> F
F --> G[Finish Layer]
Summary: Maintain specified thickness, puncture bubbles immediately while hot, and refer IS 13026 for detailed specs in LPG-related industries.
IS 13074: Repair of Damaged Bitumen Mastic Flooring
Damaged Area Preparation (Clause 8.1):
Bubble Handling during Laying (Clause 7.3.2.1):
Maintenance (Clause 9.1):
| Step | Description |
|---|---|
| Cut damaged area | Rectangular cut-out |
| Remove damaged layer | Blow lamp technique preferred |
| Replace | Use fresh bitumen mastic |
| Bubble management | Puncture and repair hot mastic |
| Cleaning & maintenance | Regular cleaning; immediate spill removal |
flowchart TD
A[Damaged Area Identified] --> B[Cut Rectangular Section]
B --> C[Remove Damaged Layer (Blow Lamp)]
C --> D[Apply New Bitumen Mastic]
D --> E{Bubbles Formed?}
E -- Yes --> F[Puncture Bubbles While Hot]
E -- No --> G[Allow to Set]
F --> G
G --> H[Periodic Cleaning & Spill Removal]
This concise approach ensures durability and integrity of bitumen mastic flooring per IS 13074.
IS 13074 - Maintenance of Bitumen Mastic Flooring (Clause 9.1)
Maintenance Requirements:
Additional Notes:
| Maintenance Activity | Frequency | Method |
|---|---|---|
| Dirt and dust removal | Periodic | Lukewarm water + detergent |
| Oil, grease, fat spills | Immediate | Prompt cleaning with suitable agents |
flowchart LR
A[Flooring Usage] --> B{Spill Occurs?}
B -- Yes --> C[Immediate Cleaning]
B -- No --> D[Periodic Cleaning]
C --> E[Use detergent + lukewarm water]
D --> E
E --> F[Maintain flooring integrity]
This ensures the flooring remains safe and functional with minimal upkeep.
Frequently Asked
According to IS 13074, the recommended thickness for bitumen mastic flooring is:
| Parameter | Value |
|---|---|
| Thickness of flooring | 20 mm to 25 mm |
| Special conditions | As mutually agreed |
This thickness ensures durability and impermeability, especially for hydrocarbon service environments.
Loading diagram...
This diagram shows the flow from base to final flooring with thickness control and service considerations.
Preparation of Base Surface before Laying Bitumen Mastic (IS 13074)
This preparation ensures a uniform thickness and strong adhesion of bitumen mastic, which is jointless and impervious to moisture (Clauses 7.3.2 & 3.1).
Loading diagram...
Equipment necessary for heating and applying bitumen mastic as per IS 13074:
Key points:
Loading diagram...
This setup ensures uniform heating, ease of application, and quality flooring with impervious, jointless bitumen mastic.
To ensure durability of multi-layer bitumen mastic flooring as per IS 13074:
Summary Table:
| Aspect | Requirement |
|---|---|
| Total Thickness | 20–25 mm |
| Layers | One or more, uniform thickness |
| Surface | Jointless, moisture impervious |
| Tools for Control | Hand tools, gauges, straight edges |
| Reference Standard | IS 13026:1990 for hydrocarbon use |
This approach ensures a durable, impervious, and service-specific flooring system.
Maintenance of Bitumen Mastic Flooring in Hydrocarbon Handling Industries (IS 13074)
According to Clause 9.1 of IS 13074:
| Maintenance Activity | Frequency/Action |
|---|---|
| Dirt and dust removal | Periodic with lukewarm water and detergent |
| Oil, fat, grease spills | Immediate cleaning |
| Inspection for damage | Regular (as per service conditions) |