Specification for Portable Fire Extinguishers - Halon 1211 Type

IS 11108-1984 specifies the requirements for portable fire extinguishers using Halon 1211 as the extinguishing agent. It covers design, construction, materials, performance, and testing criteria for extinguishers with capacities ranging from 1.25 to 6.5 kg, ensuring safety and reliability in fire suppression. This standard is essential for manufacturers, safety engineers, and fire safety professionals involved in the production, selection, and maintenance of Halon 1211 type portable fire extinguishers in India.

12Sections
119Clauses Indexed
AI Search Ready
1984Edition
Fire FightingCategory
Alternative search terms: IS 11108 PDF, IS 11108 pdf free download, IS 11108 free download pdf, IS11108 PDF, IS-11108 PDF, IS 11108 1984 PDF, IS 11108:1984 PDF, IS 11108-1984 PDF, IS 11108 (1984) PDF, IS 11108 1984 edition PDF, IS 11108 edition 1984 PDF

What This Standard Covers

IS 11108-1984 specifies the requirements for portable fire extinguishers using Halon 1211 as the extinguishing agent. It covers design, construction, materials, performance, and testing criteria for extinguishers with capacities ranging from 1.25 to 6.5 kg, ensuring safety and reliability in fire suppression. This standard is essential for manufacturers, safety engineers, and fire safety professionals involved in the production, selection, and maintenance of Halon 1211 type portable fire extinguishers in India.

Who Uses This Standard

  • Fire Safety Engineers
  • Portable Fire Extinguisher Manufacturers
  • Safety Inspectors
  • Fire Protection System Designers
  • Quality Assurance Professionals
  • Maintenance Technicians
  • Regulatory Compliance Officers

Key Topics Covered

Material specifications for extinguisher components
Design and construction requirements
Capacity and filling ratios
Pressurization with dry nitrogen
Performance criteria including discharge duration and range
Hydrostatic and drop testing procedures
Marking and labeling requirements
Valve and discharge fittings specifications
Welding and fabrication standards
Sampling and conformity evaluation
Safety features and operational instructions
Certification and Standard Mark usage

Table of Contents

1Scope

IS 11108 - Scope: Key Specifications & Tables

Materials of Construction (Clause 4.1, Table 1)

ComponentMaterialIS Standard Reference
BodySteel (Grade D or DD)IS 513-1973
Neck ringSteelIS 6240-1976* or IS 226-1975 or others
Valve bodyLeaded tin bronzeGrade LTB-2, IS 318-1957
NozzleExtruded brassGrade I, IS 291-1977 or IS 319-1974
SpringSteel (plated)Grade I, IS 4454 (Part 1)-1975
Piercer/spindleSteel (04 Cr 13)IS 6528-1972
Siphon tubeBrass copper alloyAlloy No. 2, IS 407-1981 or IS 1545-1969
Sealing nuts, disc, discharge fittingBrassIS 291-1977 or IS 319-1974
WasherRubberIS 937-1981
Sealing discCopperIS 1972-1977

Construction (Clause 6.1)

  • Body shape: Cylindrical
  • Filling ratio: ≤ 0.75

Discharge Performance (Clause 10.5, Table)

Capacity (kg)Min. Jet Throw (s)Max. Discharge Time (s)Min. Jet Range (m)
1.258142
2.58162
410203
512244
6.514284
  • Discharge test at 27 ± 5°C, horizontal direction, still air.
  • Minimum 95% contents discharge within specified time
2Materials of Construction

IS 11108: Materials of Construction (Clause 4.1 & Table 1)

ComponentMaterialRelevant IS Standard(s)
BodySteel (Grade D or DD)IS: 513-1973
Neck ringSteelIS: 6240-1976 or IS: 226-1975 or IS: 1875-1978 or IS: 2073-1970 or IS: 4855-1969
Valve bodyLeaded tin bronze (LTB-2)IS: 318-1957
NozzleExtruded brass sectionIS: 291-1977 Grade I or IS: 319-1974 Type I
SpringSteel (plated)IS: 4454 (Part 1)-1975 Grade I
Piercer/spindleSteel (04 Cr 13)IS: 6528-1972
Siphon tubeBrass copper alloy No. 2IS: 407-1981 or IS: 1545-1969
Sealing nuts, Piercer disc, Discharge fittingExtruded brass sectionIS: 291-1977 Grade I or IS: 319-1974 Type I
WasherRubberIS: 937-1981
Sealing discCopperIS: 1972-1977

Key Formula for Minimum Wall Thickness (Clause 7.1.1)

  • For cylindrical shell:

[ t = \frac{p \times D_o}{200 \times 0.8 \times J \times R_e + p} ]

  • For tori-spherical end:

[ t = \frac{p \times D_o}{200 \times 0.8 \times J \times R_e + p} ]

  • For semi-ellipsoidal end:

[ t = \frac{p \times D_o}{200 \times 0.8 \times J \times R_e + p} \times \frac{K(0

3Design and Construction

IS 11108 - Key Design & Construction Specs

1. Materials of Construction (Clause 4.1, Table 1)

ComponentMaterialRelevant IS Standard(s)
BodySteel (Grade D or DD)IS: 513-1973
Neck ringSteelIS: 6240-1976, or IS: 226-1975, 1875-1978, 2073-1970, 4855-1969
Valve bodyLeaded tin bronze (LTB-2)IS: 318-1957
NozzleExtruded brassIS: 291-1977, IS: 319-1974
SpringPlated Steel (Grade I)IS: 4454 (Part 1)-1975
Piercer/spindleSteel (04 Cr 13)IS: 6528-1972
Siphon tubeBrass copper alloy No. 2IS: 407-1981, IS: 1545-1969
Sealing nuts, disc, discharge fittingExtruded brassIS: 291-1977, IS: 319-1974
WasherRubberIS: 937-1981
Sealing discCopperIS: 1972-1977

2. Design Specifications (Clause 6.1)

  • Body shape: Cylindrical
  • Maximum filling ratio: 0.75

3. Performance Requirements (Clause 10.5, Table 10)

Capacity (kg)Min. Throw Duration (s)Max. Discharge Time for 95% Content (s)Min. Jet Range (m)
1.258142
2.58162
410203
512244
6.5
4Capacity and Filling Ratio

IS 11108 Key Points on Capacity and Filling Ratio

  • Water Capacity: Max 6.5 liters (Clause 2.1). Extinguishers covered: 1.25, 2.5, 4, 5, and 6.5 kg.

  • Filling Ratio: Shall not exceed 0.75 (Clause 6.1).
    Filling Ratio = (Mass of extinguishing agent) / (Volume of container × Density)

  • Charging Pressure:

    • For 2.5 kg: 10.5 ± 0.5 kgf/cm² with +50% tolerance (Clause 2.5b)
    • For 4 kg: Specified in Clause 2.5c (details similar to 2.5 kg)
  • Discharge Test Requirements (Clause 10.5):

Capacity (kg)Min. Jet Throw Time (s)Max. Time to Discharge 95% (s)Min. Jet Range (m)
1.258142
2.58162
410203
512244
6.514284
  • Discharge Condition: Horizontal direction, still air, at 27 ± 5°C.

Summary Formula for Filling Ratio

[ \text{Filling Ratio} = \frac{\text{Mass of extinguishing agent}}{\text{Volume of container} \times \text{Density of agent}} \leq 0.75 ]

This ensures safe and effective filling without over-pressurizing the extinguisher.


flowchart TD
    A[Extinguisher Capacity] --> B[Filling Ratio ≤ 0.75]
    B --> C[Charging Pressure]
    C --> D[Discharge Test]
    D --> E[Minimum Jet Time & Range]

This encapsulates the key design and test parameters per IS 11108.

5Pressurization and Charging

Pressurization and Charging - IS 11108 Key Points

1. Body Shape & Filling Ratio (Clause 6.1)

  • Shape: Cylindrical
  • Filling Ratio: ≤ 0.75 (i.e., max 75% of volume filled with extinguishing agent)

2. Charging Pressure (Clause 1.25)

  • Charge Weight: 1.25 kg ± 50 g (for specified agent)
  • Charging Pressure: 9.5 kgf/cm² ± 0.5 kgf/cm² (approx. 0.93 MPa ± 0.05 MPa)

3. Pressure Gauge (Clause 7.6)

  • Must be fitted (except universal types)
  • Should indicate:
    • Normal charging pressure
    • Partial/full discharge status

4. Materials for Components (Clause 4.1, Table 1)

ComponentMaterialIS Standard
BodySteel (Grade D/DD)IS: 513-1973
Neck ringSteelIS: 6240-1976 or others
Valve bodyLeaded tin bronzeIS: 318-1957 (Grade LTB-2)
NozzleBrassIS: 291-1977, IS: 319-1974
SpringSteel (plated)IS: 4454 (Part 1)-1975
Piercer/spindleSteel (04 Cr 13)IS: 6528-1972
Siphon tubeBrass copper alloyIS: 407-1981, IS: 1545-1969
Sealing nuts/discBrass/CopperIS: 291-1977, IS: 1972-1977

Formula for Charging Pressure Check

[ P_{charge} = 9.5 \pm 0.5 , \text{kgf/cm}^2 ]


Summary Diagram: Pressurization & Charging Flow

flowchart TD
    A[Extinguisher Body (Cylindrical)] --> B[Filling with Agent (≤ 
6Performance Requirements

IS 11108: Performance Requirements Summary

Key Specifications:

  • Body Shape: Cylindrical (Clause 6.1)
  • Filling Ratio: ≤ 0.75 (Clause 6.1)
  • Test Temperature: 27 ± 5°C (Clause 10.5)
  • Discharge: Continuous, horizontal stream in still air (Clause 10.5)
  • Discharge Mass: ≥ 95% of liquid content (full mass difference) (Clause 10.5)

Performance Test (Clause 10.5):

Capacity (kg)Min. Throw Duration (s)Max. Discharge Time for 95% (s)Min. Range of Jet (m)
1.258142
2.58162
410203
512244
6.514284

Notes:

  • The extinguisher must maintain the throw for the minimum period.
  • Discharge must be completed within the maximum time.
  • The jet range is the minimum horizontal distance the stream should reach.

flowchart LR
    A[Full Charged Extinguisher] --> B[Discharge Test at 27±5°C]
    B --> C{Discharge ≥ 95% of content?}
    C -- Yes --> D[Throw duration ≥ Min. Period]
    C -- No --> E[Fail Test]
    D --> F[Discharge completed ≤ Max. Time]
    F --> G[Jet Range ≥ Min. Distance]
    G --> H[Pass Performance Test]

This ensures reliable and effective extinguisher performance as per IS 11108.

7Testing Procedures

IS 11108: Testing Procedures Key Points

Sampling (Clause 1.2.1 & A-1.2.1)

  • Samples are randomly taken from a lot as per criteria in A-1.2.2.
  • One sample tested for drop test (Clause 10.3) and performance test (Clause 10.5).

Material (Clause 4.1)

  • Materials for extinguisher components specified in Table 1 (refer IS 11108 for details).

Performance Test (Clause 10.5)

Capacity (kg)Min. Throw Duration (s)Max. Discharge Time for 95% (s)Min. Jet Range (m)
1.258142
2.58162
410203
512244
6.514284
  • Extinguisher filled to marked full mass.
  • Discharge at 27 ± 5°C in normal working position.
  • At least 95% liquid content must be expelled continuously.
  • Jet discharged horizontally in still air.

Summary Formula for Discharge Test:

  • Discharge Time ≤ Max. Discharge Time for 95% content
  • Jet Range ≥ Specified minimum
flowchart LR
    A[Sample Selection] --> B[Drop Test (Clause 10.3)]
    A --> C[Performance Test (Clause 10.5)]
    C --> D{Check Discharge}
    D -->|≥95% expelled| E[Pass]
    D -->|<95% expelled| F[Fail]

This ensures extinguisher reliability and compliance with IS 11108.

8Marking and Labeling

IS 11108: Key Marking & Labeling Specifications

1. Fire Class Marking (Clause 9.3)

  • Letters: B and C (fire classes)
  • Letter size: 2.5 cm height, black color
  • Enclosure:
    • B: inside a green square (4 cm size)
    • C: inside a green circle (2 cm radius)
  • Green color: Shade No. 284 as per IS 5-1978
  • Paint: Conforming to IS 2932-1974 (electroplated coating thickness test methods)

2. Mandatory Markings on Extinguishers (Clause 11.1)

  • Manufacturer’s name & trademark
  • Method of operation (prominent)
  • Words: "Halon 1211"
  • Capacity & charged pressure; radiographed status
  • Warning: "Send for re-charging immediately after use"
  • Year of manufacture
  • Test pressure & capacity (kg)
  • Tare weight and full weight (gas + liquid)
  • Warning: "WARNING: Ventilate the area after use"

3. BIS Certification Mark (Clause 11.2)

  • Optional Standard Mark usage governed by BIS Act 1986
  • License conditions available from BIS

graph TD
A[Extinguisher] --> B[Marking]
B --> C[Fire Class Letters (B & C)]
B --> D[Manufacturer Info]
B --> E[Operational Instructions]
B --> F[Capacity & Pressure]
B --> G[Warnings]

This ensures clear identification, safe use, and regulatory compliance.

9Safety Features

IS 11108: Safety Features - Key Specifications & Tables


1. Body Shape & Filling Ratio (Clause 6.1)

  • Shape: Cylindrical
  • Filling Ratio: ≤ 0.75 (to ensure safe vapor space)

2. Materials of Construction (Clause 4.1, Table 1)

ComponentMaterialIS Standard Reference
BodySteel (Grade D or DD)IS 513-1973
Neck RingSteelIS 6240-1976 or IS 226/1875/2073/4855
Valve BodyLeaded Tin Bronze (LTB-2)IS 318-1957
NozzleExtruded Brass SectionIS 291-1977 or IS 319-1974
SpringSteel (Plated)IS 4454 (Part 1)-1975
Piercer/SpindleSteel (04 Cr 13)IS 6528-1972
Siphon TubeBrass Copper Alloy No. 2IS 407-1981 / IS 1545-1969
Sealing Nuts/DiscsExtruded Brass SectionIS 291-1977 / IS 319-1974
WasherRubberIS 937-1981
Sealing DiscCopperIS 1972-1977

3. Discharge Performance (Clause 10.5, Table 10)

Capacity (kg)Min. Throw Duration (s)Max. Discharge Time for 95% Content (s)Min. Jet Range (m)
1.258142
2.58162
410203
512244
6.51428
10Sampling and Conformity Criteria

IS 11108: Sampling and Conformity Criteria

Sampling Plan (Clause 1.2.2, Appendix A)

Number of Items in LotSample Size (Number of Samples)
Up to 253
26 to 505
51 to 1008
101 to 2008% of lot size
  • Samples must be selected randomly from the lot.

Key Points (Appendix A-0.1)

  • Fire extinguishers require high reliability due to critical safety function.
  • Quality control involves:
    • Design adequacy
    • Raw materials and components control
    • Process control during manufacture and assembly

Conformity Criteria

  • The lot is accepted or rejected based on test results of the sampled items.
  • The risk of failure is minimized by strict adherence to sampling sizes and quality control.

Summary:
Use the above sampling sizes for testing fire extinguisher lots. Ensure random sampling and rigorous quality control to guarantee reliability.

flowchart TD
    A[Lot of Fire Extinguishers] --> B{Lot Size?}
    B -->|Up to 25| C[Take 3 Samples]
    B -->|26 to 50| D[Take 5 Samples]
    B -->|51 to 100| E[Take 8 Samples]
    B -->|101 to 200| F[Take 8% Samples]
    C --> G[Test Samples]
    D --> G
    E --> G
    F --> G
    G --> H{Conformity?}
    H -->|Yes| I[Accept Lot]
    H -->|No| J[Reject Lot]

This ensures reliability and safety compliance per IS 11108.

11Certification and Standard Mark

IS 11108 - Certification and Standard Mark Key Points

1. BIS Certification Marking (Clause 11.2)

  • The product may be marked with the BIS Standard Mark.
  • Use of the Standard Mark is governed by the Bureau of Indian Standards Act, 1986.
  • Licence conditions for using the Standard Mark are available from BIS.

2. Sampling and Conformity Criteria (Clause 12 & 1.2.7)

  • In absence of manufacturer's test certificate, sample fire extinguisher components are individually tested for compliance.
  • Charge quality must meet the specification requirements.

3. Materials of Construction (Table 1, Clause 4.1)

ComponentMaterialIS Standard Reference
BodySteel (Grade D or DD)IS: 513-1973
Neck ringSteelIS: 6240-1976 or IS: 226/1875/2073/4855
Valve bodyLeaded tin bronze (LTB-2)IS: 318-1957
NozzleExtruded brassIS: 291-1977 / IS: 319-1974
SpringSteel (plated)IS: 4454 (Part 1)-1975
Piercer/spindleSteel (04 Cr 13)IS: 6528-1972
Siphon tubeBrass copper alloyIS: 407-1981 / IS: 1545-1969
Sealing nuts, discExtruded brassIS: 291-1977 / IS: 319-1974
WasherRubberIS: 937-1981
Sealing discCopperIS: 1972-1977

Summary Diagram: Certification Process Flow

flowchart TD
    A[Manufacturer] --> B[Apply for BIS Licence]
    B --> C[BIS Review & Testing]
    C --> D{Compliance?}
    D -- Yes --> E[Grant Licence & Standard Mark Use]
    D -- No --> F[Reject Application]
    E --> G[Mark Product with
12Annexures and References

IS 11108 Annexures & References – Key Specifications and Tables

Table 1: Materials of Construction (Clause 4.1)

ComponentMaterialRelevant IS Standard(s)
BodySteel (Grade D or DD)IS: 513-1986
Neck ringSteelIS: 6240-1976, IS: 226-1975, IS: 1875-1978, IS: 2073-1974, IS: 9550-1980
Valve bodyLeaded tin bronzeGrade LTB-2, IS: 318-1957
NozzleExtruded brassGrade I IS: 291-1977, Type I IS: 319-1974
SpringSteel (plated)Grade I, IS: 454 (Part 1)-1981
Piercer/spindleSteelIS: 6528-1972
Siphon tubeBrass copperAlloy No. 2 IS: 407-1981, IS: 1545-1982
Sealing nuts, disc, discharge fittingExtruded brassGrade I IS: 291-1977, Type I IS: 319-1974
WasherRubberIS: 937-1981
Sealing discCopperIS: 1972-1977

Important Amendments & Notes:

  • Steel body material updated to IS: 513-1986.
  • Neck ring steel standards include IS: 6240-1976 and IS: 9550-1980.
  • Spring steel standard updated to IS: 454 (Part 1)-1981.
  • Siphon tube brass standard updated to IS: 1545-1982.
  • Mechanical failure test added to clause 10.1.
  • Finish requirements for extinguisher body clarified (Clause 9.1).

References for Material Standards:

  • IS: 513 – Cold-rolled low carbon steel sheets.
  • IS: 6240 – Hot-rolled steel plates for low-pressure gas cylinders.
  • IS: 318 – Leaded tin bronze ingots and casting.
  • IS:

Popular Questions About IS 11108

?What materials are specified for the construction of Halon 1211 extinguishers?

IS 11108 specifies materials for Halon 1211 portable fire extinguishers focusing on durability, corrosion resistance, and safety.

Key Material Requirements:

  • Cylinder Body: Typically made of mild steel or stainless steel with anti-corrosive treatment (e.g., painting or galvanizing).
  • Valve and Operating Mechanism: Made from brass, stainless steel, or corrosion-resistant alloys to withstand chemical exposure.
  • Seals and Gaskets: Use synthetic rubber or elastomeric materials compatible with Halon 1211.
  • External Coating: Anti-corrosive paint or powder coating to prevent rust and degradation.

Summary Table:

ComponentMaterial Specification
CylinderMild steel / Stainless steel + anti-corrosive treatment
Valve & MechanismBrass / Stainless steel / Corrosion-resistant alloys
Seals & GasketsSynthetic rubber / Elastomers compatible with Halon 1211
External CoatingAnti-corrosive paint or powder coating

This ensures structural integrity and chemical compatibility for safe and effective extinguisher performance.

?What are the performance requirements for discharge duration and range?

According to IS 11108 Clause 10.5, the performance requirements for discharge duration and range of fire extinguishers are:

  • The extinguisher must discharge at least 95% of its liquid contents continuously at 27 ± 5°C in its normal working position.
  • The discharge stream should be horizontal in still air.
Capacity (kg)Min. Jet Throw Duration (s)Max. Discharge Time for 95% Content (s)Min. Range of Jet Throw (m)
1.258142
2.58162
410203
512244
6.514284

Key points:

  • The nozzle design must ensure these performance criteria (Clause 7.5.1).
  • Tests are conducted at 27 ± 5°C.
  • The throw must be continuous and meet the minimum range specified.

This ensures effective and sustained discharge during firefighting.

?How is the extinguisher pressurized and what pressure levels are required?

Pressurization of Extinguishers (IS 11108):

  • Gas Used: Extinguishers are pressurized with dry nitrogen (Clause 5.11, IS:1747-1972).

  • Pressure Levels:

    • For 1.25 kg capacity, hydrostatic test pressure = 2.5 MN/m² (25 kgf/cm²) for 30 seconds (Clause 10.1).
    • For capacities >1.25 kg, test pressure = 3 MN/m² (30 kgf/cm²) for 30 seconds.
  • Pressure Gauge:

    • Except for universal types, extinguishers must have a pressure gauge indicating:
      • Normal charging pressure
      • When pressure is partially or fully released (Clause 7.6).

Summary Table:

CapacityHydrostatic Test PressureDurationPressurizing Gas
1.25 kg2.5 MN/m² (25 kgf/cm²)30 secondsDry Nitrogen
Above 1.25 kg3 MN/m² (30 kgf/cm²)30 secondsDry Nitrogen

Operation Note:

  • 1.25 kg inverted type: Pressurized and discharged by inverting and piercing valve.
  • All capacities upright type: Use squeeze grip valve with spring-loaded spindle for controlled discharge.
Loading diagram...

This ensures safe operation and reliable pressure maintenance in fire extinguishers per IS 11108.

?What tests must the extinguisher pass to ensure safety and reliability?

According to IS 11108, fire extinguishers must pass the following key tests to ensure safety and reliability:

1. Hydrostatic Test (Clause 10.1)

  • 1.25 kg capacity: Withstand 2.5 MN/m² (25 kgf/cm²) for 30 seconds.
  • Higher capacities: Withstand 3 MN/m² (30 kgf/cm²) for 30 seconds.
  • No leakage or visible distortion allowed.
  • Test done before painting and after heat treatment.

2. Drop Test (Clause 10.3)

  • Temperature: 27 ± 5°C.
  • Filled with water to 90% volume, pressurized to charged pressure.
  • Dropped from 3 m height on concrete twice:
    • Cylinder axis horizontal.
    • Cylinder axis vertical (head up).
  • No leakage or pressure loss after test (checked by immersion in water).

3. Bursting Pressure Test (Clause 1.2.6)

  • Manufacturer must provide a test certificate or test one sample per lot.
  • Sample must pass bursting pressure requirements.

4. Discharge Performance Test (Clause 10.5)

  • Discharge ≥95% of liquid contents at 27 ± 5°C.
  • Continuous jet discharge with minimum throw duration and range as per capacity:
Capacity (kg)Min Throw Duration (s)Max Discharge Time (s)Min Range (m)
1.258142
2.58162
410203
512244
6.514284

These tests ensure structural integrity, leak tightness, and effective discharge performance under normal conditions.

?What markings and labels are mandatory on the extinguisher?

According to IS 11108, the mandatory markings and labels on a Halon 1211 fire extinguisher are:

  • Manufacturer's name and trade-mark
  • Method of operation in prominent letters and a pictorial diagram
  • The words "Halon 1211" prominently displayed
  • Capacity and charged pressure, including whether the cylinder is radiographed
  • The phrase "Send for re-charging immediately after use"
  • Year of manufacture
  • Test pressure and capacity (kg)
  • Tare weight and full weight (gas + liquid)
  • The warning "WARNING: Ventilate the area after use"
  • Markings for fire class suitability: letters B and C in 2.5 cm black font, inside a green square (4 cm) and green circle (2 cm radius) respectively, per IS 2190-1979
  • The extinguisher body must be painted fire red (IS shade No. 536)

These ensure clear identification, safe handling, and compliance with fire safety standards.

Loading diagram...

This labeling ensures compliance and user safety.