IS 10790 Part 1 (1984) specifies the methods for sampling prestressing steel used in prestressed concrete construction. It provides detailed procedures for selecting, inspecting, and testing steel samples to ensure conformity with physical, dimensional, and visual quality requirements. This standard is essential for manufacturers, quality control engineers, and construction professionals involved in producing or using prestressing steel to maintain consistent material quality and compliance with relevant specifications.
Overview
IS 10790 Part 1 (1984) specifies the methods for sampling prestressing steel used in prestressed concrete construction. It provides detailed procedures for selecting, inspecting, and testing steel samples to ensure conformity with physical, dimensional, and visual quality requirements. This standard is essential for manufacturers, quality control engineers, and construction professionals involved in producing or using prestressing steel to maintain consistent material quality and compliance with relevant specifications.
Audience
Contents
Structure
IS 10790 Part 1 - Scope Key Points
| Stage | Frequency of Inspection/Test |
|---|---|
| Raw material | One coil per heat/cast for chemical, physical, metallurgical |
| After patenting | Two coils per patenting batch/lot |
| Before final pass in drawing | Dimensional check every 4 hours |
| After final pass in drawing | Dimensional check & UTS for each coil |
| After stress relieving | Every 5th coil: dimensions, proof stress, UTS, elongation, indentation<br>Monthly: relaxation & stress corrosion susceptibility |
| Lot Size | Visual Sample Size | Visual Acceptance No. | Dimensional & Weight Sample Size | Dimensional & Weight Acceptance No. |
|---|---|---|---|---|
| Up to 25 | 8 | 0 | 5 | 0 |
| 26 to 50 | 13 | 1 | 8 | 0 |
| 51 to 100 | 20 | 1 | 13 | 1 |
| 101 to 150 | 32 | 2 | 20 | 1 |
| 151 to 300 | 50 | 3 | 32 | 2 |
| 301 to 500 | 80 | 5 | 50 | 3 |
| 501 and above | 125 | 7 | 80 | 5 |
flowchart LR
A[Raw Material Inspection
IS 10790 Part 1: Key Definitions, Sampling & Testing Specifications
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
Summary:
flowchart TD
A[Manufactured Lot] --> B[Visual, Dimensional & Weight Inspection]
B -->|Pass| C[Prepare Test Specimens]
C --> D[Tensile & Mechanical Tests]
D --> E{Conformity?}
E -->|Yes|
IS 10790 Part 1: Process Inspection Key Points
| Stage | Inspection Frequency & Tests |
|---|---|
| Raw material | Test one coil from every heat/cast for chemical, physical, metallurgical properties |
| After patenting | Test two coils per patenting batch/lot |
| Before final pass in drawing | Dimensional check every 4 hours |
| After final pass in drawing | Dimensional check and Ultimate Tensile Strength (UTS) test for each coil |
| After stress relieving | Every 5th coil: dimensions, proof stress, UTS, elongation, ductility, indentation; monthly coil: relaxation & stress corrosion susceptibility |
flowchart TD
A[Raw Material] -->|Test 1 coil/heat| B[After Patenting]
B -->|Test 2 coils/batch| C[Before Final Pass]
C -->|Dimensional check every 4 hrs| D[After Final Pass]
D -->|Dimensional + UTS each coil| E[After Stress Relieving]
E -->|Every 5th coil: mechanical tests| F[Monthly coil: relaxation & corrosion tests]
This ensures continuous quality monitoring and conformity to IS 10790 requirements.
IS 10790 Part 1 — Lot Inspection Key Points
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
This method ensures statistical quality control and compliance with specifications.
IS 10790 Part 1: Sampling Scale & Criteria for Conformity
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
| Lot Size | Number of Items to Select |
|---|---|
| Up to 50 | 2 |
| 51 to 150 | 3 |
| 151 to 500 | 5 |
| 501 and above | 8 |
flowchart TD
A[Start: Lot Received] --> B[Visual Inspection]
B -->|Defectives ≤ Acceptance Number| C[Dimensional & Weight Sampling]
B -->|Defectives > Acceptance Number| D[Lot Rejected]
C -->|Defectives ≤ Acceptance Number| E[Lot Accepted]
C -->|Defectives > Acceptance Number| D
Use these tables and criteria for sampling and acceptance decisions per IS 10790 Part 1 Clause 4.3.
Selection and Examination of Samples as per IS 10790 Part 1 (1984):
| Lot Size | Visual Sample Size | Visual Acceptance Number | Dimensional & Weight Sample Size | Dimensional & Weight Acceptance Number |
|---|---|---|---|---|
| Up to 25 | 8 | 0 | 5 | 0 |
| 26 to 50 | 13 | 1 | 8 | 0 |
| 51 to 100 | 20 | 1 | 13 | 1 |
| 101 to 150 | 32 | 2 | 20 | 1 |
| 151 to 300 | 50 | 3 | 32 | 2 |
| 301 to 500 | 80 | 5 | 50 | 3 |
| 501 and above | 125 | 7 | 80 | 5 |
| Number of Items in Lot | Number of Items to be Selected |
|---|---|
| Up to 50 | 2 |
| 51 to 150 | 3 |
| 151 to 500 | 5 |
| 501 and above | 8 |
This systematic sampling ensures quality control and compliance with IS standards.
IS 10790 Part 1 — Visual, Dimensional & Weight Characteristics
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
flowchart TD
A[Select Sample for Visual Inspection] --> B{Defectives ≤ Acceptance Number?}
B -- Yes --> C[Select Sample for Dimensional & Weight Inspection]
B -- No --> D[Inspect Full Lot and Remove Defectives (if agreed)]
C --> E{Defectives ≤ Acceptance Number?}
E -- Yes --> F[Lot Accepted]
E -- No --> G[Lot Rejected]
This ensures quality control by statistically verifying visual and
IS 10790 Part 1: Visual Characteristics Inspection
| Lot Size | Sample Size (Visual) | Acceptance Number (Visual) | Sample Size (Dimensional & Weight) | Acceptance Number (Dimensional & Weight) |
|---|---|---|---|---|
| Up to 25 | 8 | 0 | 5 | 0 |
| 26 to 50 | 13 | 1 | 8 | 0 |
| 51 to 100 | 20 | 1 | 13 | 1 |
| 101 to 150 | 32 | 2 | 20 | 1 |
| 151 to 300 | 50 | 3 | 32 | 2 |
| 301 to 500 | 80 | 5 | 50 | 3 |
| 501 and above | 125 | 7 | 80 | 5 |
flowchart TD
A[Start: Lot Received] --> B{Select Sample Size<br>from Table 2}
B --> C[Visual Inspection]
C --> D{Defectives ≤ Acceptance Number?}
D -- Yes --> E[Dimensional & Weight Inspection]
D -- No --> F[Reject or 100% Inspection]
E --> G{Defectives ≤ Acceptance Number?}
G -- Yes --> H[Lot Accepted]
G -- No --> F
This ensures quality
IS 10790 Part 1: Physical Characteristics Testing
| Number of Items in Lot | Number of Items to Select |
|---|---|
| Up to 50 | 2 |
| 51 to 150 | 3 |
| 151 to 500 | 5 |
| 501 and above | 8 |
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
flowchart LR
A[Lot Size] --> B{Select Number of Samples}
B -->|Up to 50| C[2 Samples]
B -->|51 to 150| D[3 Samples]
B -->|151 to 500| E[5 Samples]
B -->|501 and above| F[8 Samples]
A --> G{Visual & Dimensional Tests}
G --> H[Refer Table for Sample Size & Acceptance Number]
This concise guide ensures compliance with IS 10790 Part 1 for physical testing sampling.
IS 10790 Part 1: Statistical Evaluation & Record Keeping
Clause 3.2.2:
Clause 3.3:
Clause 4.3.1.2 - Sampling & Acceptance (Table 2):
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
flowchart LR
A[Inspection & Testing] --> B[Record Data]
B --> C[Statistical Evaluation]
C --> D{Conforms to Spec?}
D -->|Yes| E[Issue Test Certificate]
D -->|No| F[
Handling Non-Conforming Lots as per IS 10790 Part 1
| Lot Size | Visual Sample Size | Visual Acceptance No. | Dimensional & Weight Sample Size | Dimensional & Weight Acceptance No. |
|---|---|---|---|---|
| Up to 25 | 8 | 0 | 5 | 0 |
| 26 to 50 | 13 | 1 | 8 | 0 |
| 51 to 100 | 20 | 1 | 13 | 1 |
| 101 to 150 | 32 | 2 | 20 | 1 |
| 151 to 300 | 50 | 3 | 32 | 2 |
| 301 to 500 | 80 | 5 | 50 | 3 |
| 501 and above | 125 | 7 | 80 | 5 |
flowchart TD
A[Start: Lot Inspection] --> B{Visual Inspection}
B -- Pass --> C[Random Sampling for Dimensional & Weight]
B -- Fail --> D[Lot Non-Conforming]
C --> E{Number of Defectives ≤ Acceptance No.?}
E -- Yes --> F[Lot Conforming]
E -- No --> D
Note:
This method ensures statistically controlled quality assurance during production.
IS 10790 Part 1: Reporting and Documentation Key Points
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance No. | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
flowchart TD
A[Inspection Data] --> B[Test Certificate]
B --> C[Reporting]
C --> D[Tabulation & Summarization]
C --> E[Diagrammatic Representation]
D --> F[Statistical Tests: t, F, Normal]
E --> G[Control Charts, χ² Test]
F --> H[Regression & AN
Frequently Asked
IS 10790 Part 1 (1984) prescribes standardized sampling methods for prestressing steel to ensure representative quality testing. Although the exact clause is not provided, typical IS sampling methods include:
| Batch Size (tons) | Number of Samples to be Taken |
|---|---|
| Up to 50 | 1 |
| 50 to 200 | 2 |
| Above 200 | 3 or more |
Loading diagram...
For precise sampling details, refer to the exact clauses in IS 10790-1 (1984).
Acceptable Quality Level (AQL) in IS 10790 Part 1
Definition (Clause 2.11):
AQL is the maximum percent defective considered satisfactory as a process average during sampling inspection.
Application:
Sampling and Acceptance Criteria (Table 2):
| Lot Size | Visual Characteristics | Dimensional & Weight Characteristics |
|---|---|---|
| Sample Size | Acceptance Number | |
| Up to 25 | 8 | 0 |
| 26 to 50 | 13 | 1 |
| 51 to 100 | 20 | 1 |
| 101 to 150 | 32 | 2 |
| 151 to 300 | 50 | 3 |
| 301 to 500 | 80 | 5 |
| 501 and above | 125 | 7 |
Loading diagram...
Summary:
IS 10790 Part 1 defines AQL as the max % defective acceptable, typically 2.
IS 10790 Part 1 focuses on quality control and sampling of prestressing steel but does not explicitly detail visual and dimensional inspection criteria. However, based on standard engineering practice and related IS codes (e.g., IS 1786 for high strength deformed bars), the criteria generally include:
| Parameter | Typical Tolerance/Requirement |
|---|---|
| Diameter | ±0.5 mm |
| Length | As per order, ± specified tolerance |
| Straightness | Max deviation ~1% of length |
| Surface Defects | None (no cracks, rust, seams) |
Loading diagram...
Note: For detailed criteria, refer to the relevant IS standards for prestressing steel like IS 6003 or IS 1786.
Testing and Evaluation of Physical Properties (IS 10790 Part 1):
Specimen Preparation (Clause 4.3.2.1):
Specimens for tensile strength, proof stress, elongation, etc., must represent the material and conform to relevant IS specifications ensuring uniformity.
Number of Specimens (Clause 4.3.2.2):
Number of test items is per Table 3 (not provided here). Specimens are taken from visually and dimensionally acceptable items.
Statistical Evaluation (Clause 3.2.2.1):
Use variables approach (mean, range) for tensile strength, elongation, proof stress, etc. Refer IS 7200 & IS 6200 series for detailed statistical methods.
Conformity Criteria (Clause 4.3.2.4):
| Number of Items | Criterion for Passing Lot |
|---|---|
| 2 | Both samples pass each test |
| ≥ 3 | ( X - 0.4R \geq ) minimum specification limit |
This ensures reliable, statistically sound evaluation of tensile strength, elongation, and related physical properties.
According to IS 10790 Part 1, if a lot fails to meet specified requirements:
Immediate action:
Inspection procedure (Clause 3.3.1 & Section 4):
Lot inspection steps:
This systematic approach ensures only conforming lots are accepted.
Ask AI about any clause, requirement, or provision in IS 10790 Part 1. Get instant, clause-cited responses powered by our indexed library.