Code of practice for installation and maintenance of internal fire hydrants and hose reels on premises
1989 Edition

The 1989 edition of IS 3844 outlines detailed procedures for setting up and maintaining internal fire hydrants and hose reels in buildings. It addresses system design, water storage needs, pump setups, component specifications, and routine inspections to guarantee effective fire defense inside structures. This code is vital for professionals managing fire safety infrastructure in residential, commercial, and industrial facilities.

10Sections
117Clauses Indexed
AI Search Ready
1989Edition
Fire FightingCategory
Alternative search terms: installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 pdf free download, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 free download pdf, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989:1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989-1989 PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 (1989) PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 1989 edition PDF, installation-and-upkeep-of-internal-fire-hydrants-and-hose-reels-1989 edition 1989 PDF

What This Standard Covers

The 1989 edition of IS 3844 outlines detailed procedures for setting up and maintaining internal fire hydrants and hose reels in buildings. It addresses system design, water storage needs, pump setups, component specifications, and routine inspections to guarantee effective fire defense inside structures. This code is vital for professionals managing fire safety infrastructure in residential, commercial, and industrial facilities.

Who Uses This Standard

  • Fire Protection Specialists
  • Building Systems Engineers
  • Facility Operations Managers
  • Fire Safety Inspectors
  • Civil Engineering Professionals
  • Maintenance Coordinators
  • Fire Safety Design Consultants

Key Topics Covered

Varieties of internal hydrant configurations such as wet-riser, dry-riser, and down-comer systems
Design parameters and storage capacity for static water reservoirs
Placement and specifications of pump houses and pumps
Requirements for fire service inlets and their arrangement
Methods for installing hose reels and landing valves
Water supply volume and pressure standards
Automation of pump operation and backup power provisions
Placement and intervals of rising mains and hydrants
System testing methods and acceptance standards
Maintenance timetables and inspection routines
Drainage systems and air vessel considerations
Coordination with sprinkler systems
Provision of access routes for firefighting vehicles
Specifications for materials and fittings
Safety signage and operational instructions

Table of Contents

1Scope of Application
2Referenced Indian Standards
3Terminology and Definitions
4Water Supply and Pumping System Requirements
5Internal Hydrant System Types and Components
6Specifications for Hose Reels
7Fire Pump Installation and Pump House Norms
8Initial System Testing Procedures
9Routine Maintenance and Inspection
Annex AList of Referenced Indian Standards

Popular Questions About IS 3844

?What are the specified water tank capacities for various building categories?

IS 3844 outlines the capacities for underground and terrace tanks based on factors such as building usage, height, and floor area. For residential buildings, tanks range from no underground storage with 20,000 L terrace tanks for structures up to 15 m, to 150,000 L underground tanks and no terrace tanks for buildings between 45 to 60 m. For apartments and private homes, tanks are generally omitted below 15 m but required above that height up to 24 m. Hotels have specified volumes starting at 50,000 L underground and 20,000 L terrace for buildings up to 15 m. Tank depths should not exceed 3.5 m plus a sump, and compartments should include gate valves for maintenance. Access routes for firefighting vehicles must be at least 6 meters wide, and terrace tanks must be robustly supported.

?How should fire pumps be installed and what are their power supply requirements?

Fire pumps must have an automatic backup power supply to guarantee operation during power outages, typically via a diesel generator set with automatic transfer or a dedicated emergency sub-station. Wet-riser installations require two pumps — a primary and a standby — each powered by separate sources with automatic activation triggered by pressure drops. Pumps should be mounted on a concrete foundation at least 75 mm thick with vibration dampening and sized appropriately to accommodate the pump, motor, and couplings. Horizontal split-case centrifugal pumps made from corrosion-resistant materials are preferred for reliability and durability.

?What are the required spacing and positioning guidelines for hydrants and rising mains?

Hydrants in wet-riser systems must be positioned so that no point in the protected area is more than 30 meters from a hydrant, with hydrants installed between 0.75 m and 1 m above the floor. Horizontal spacing between rising mains should not exceed 50 meters. Dry-riser systems for buildings 15 to 24 meters tall feature a two-way fire service inlet about 1 meter above ground level, with air release valves at the top and drain valves at the bottom. External hydrant piping is buried at least 1 meter underground, supported every 3 meters, and constructed from cast iron or treated steel pipes with protective measures at vehicle crossings.

?How frequently should internal fire hydrants and hose reels be inspected and tested?

Internal fire hydrants and associated valves require inspection every six months to assess inlets, landing valves, drain valves, hinges, locking mechanisms, and valve components for readiness. Hose reels should be regularly checked for leaks and damage, while an annual full hose run-out test under operating pressure ensures integrity and flow rates meet or exceed 0.5 liters per second. If testing all reels is impractical, at minimum, the highest hose reel on each rising main should be tested to verify performance.

?Is it permissible to use the wet-riser pump to supply a partial sprinkler system in some buildings?

Yes, under IS 3844 Clause 7.12, a wet-riser pump can feed a partial sprinkler system if the basement area protected is under 500 m² and the shop or departmental store area is less than 1000 m². The pump must have a minimum capacity of 2850 liters per minute and be paired with a stand-by pump of equal capacity powered by a diesel engine or generator. Both pumps should be automatic and operate from separate power supplies to ensure continuous fire protection.