IS 7834 PART 41987AI Search Enabled✦ AI Generated

injection moulded PVC socket fittings with solvent cement joints for water supplies, Part 4: Specific requirements for 90-degree tees
1987 Edition

This standard outlines the detailed manufacturing criteria, dimensions, tolerances, and identification markings for injection moulded PVC socket tee fittings with solvent cement joints at a 90-degree angle, specifically for water supply applications. It covers sizes ranging from 16 mm to 315 mm, ensuring consistent quality and compatibility in plumbing systems. The specification is vital for producers, engineers, and installers working with potable water piping networks.

8Sections
21Clauses Indexed
AI Search Ready
1987Edition
Plastic Piping SystemCategory
Alternative search terms: injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 pdf free download, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 free download pdf, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987:1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987-1987 PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 (1987) PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 1987 edition PDF, injection-moulded-pvc-90-degree-socket-tee-fittings-water-supply-1987 edition 1987 PDF

What This Standard Covers

This standard outlines the detailed manufacturing criteria, dimensions, tolerances, and identification markings for injection moulded PVC socket tee fittings with solvent cement joints at a 90-degree angle, specifically for water supply applications. It covers sizes ranging from 16 mm to 315 mm, ensuring consistent quality and compatibility in plumbing systems. The specification is vital for producers, engineers, and installers working with potable water piping networks.

Who Uses This Standard

  • Civil Engineering Professionals
  • Plumbing System Designers
  • PVC Fittings Manufacturers
  • Quality Assurance Inspectors
  • Water Distribution System Planners
  • Construction Industry Contractors
  • Standards and Compliance Specialists

Key Topics Covered

Production of injection moulded PVC 90-degree tee fittings
Dimensional specifications and permissible variances
Determination of laying length values
Conformance of socket internal diameter and length
Identification and marking protocols for fittings
Pressure classification and rating standards
Material and fabrication process guidelines
Compatibility with solvent cement bonded joints
Size range from 16 mm to 315 mm coverage
Reference to general requirements in IS 7834 Part 1
Testing and quality assurance procedures
Standardized marking mandates

Table of Contents

1Scope and Application
2Technical Requirements
2.1General Provisions
2.2Manufacturing Specifications
2.2.1Diagram and Dimensional Details of Tee
2.2.2Laying Length Specifications
2.2.3Socket Dimensions
3Marking and Identification

Popular Questions About IS 7834 PART 4

?What are the permissible dimensional tolerances for 90-degree PVC tee fittings as specified in IS 7834 Part 4?

The primary dimensional control parameter is the laying length (Z) of the 90-degree tee, which varies depending on the nominal pipe size from 16 mm up to 315 mm. Tolerances are asymmetric, allowing a slightly greater positive deviation than negative, to guarantee proper joint assembly. For example, a 16 mm tee has a laying length of 9 mm ±1 mm, while a 315 mm tee has a laying length of 158.5 mm with a +13/-1 mm tolerance. Socket internal diameter and length must align with IS 7834 Part 1 requirements. These measures ensure uniformity and interchangeability of fittings in water supply pipelines.

?Which nominal sizes of 90-degree tees are included in this standard?

This specification covers 90-degree injection moulded PVC socket tee fittings with solvent cement joints ranging from 16 mm to 315 mm in nominal diameter. The laying length (Z) for these sizes is defined with specific tolerances to maintain dimensional consistency. Socket dimensions conform to IS 7834 Part 1. Markings include manufacturer identification, fitting size, and pressure classification to ensure proper identification and usability within the specified range.

?How should 90-degree tees be marked according to IS 7834 Part 4?

Marking on 90-degree PVC tees must include the manufacturer's name or identification mark, the nominal size of the fitting, and the pressure class indicating the working pressure rating. This marking protocol is essential for traceability, quality assurance, and confirming that the fitting meets the appropriate pressure specifications. Additionally, laying length dimensions conform to the standard's table, ensuring fitment accuracy.

?What are the manufacturing requirements for injection moulded PVC 90-degree tees under this standard?

Injection moulded PVC 90-degree tees must be produced through injection moulding processes as prescribed in IS 7834 Part 1, which covers material selection, manufacturing methods, testing, and sampling procedures. The PVC compound used should be suitable for potable water fittings. The manufacturing process must ensure adherence to the defined dimensional tolerances, particularly the laying length, and the fittings must undergo marking and sampling in accordance with BIS standards to maintain consistent quality and compatibility.

?How does IS 7834 Part 4 relate to the general requirements outlined in IS 7834 Part 1?

IS 7834 Part 1 establishes the overarching requirements for injection moulded PVC socket fittings with solvent cement joints, including material specifications, manufacturing processes, testing methods, sampling, and general marking guidelines. Part 4 complements this by focusing specifically on 90-degree tee fittings, detailing precise dimensions, tolerances, and marking instructions unique to these fittings. Compliance with Part 1 is mandatory, with Part 4 providing additional details to ensure uniformity and compatibility within PVC piping systems.