IS 2690 PART 21992AI Search Enabled✦ AI Generated

Burnt clay flat terracing tiles- Specification, Part 2: Hand made
1992 Edition

The 1992 edition of IS 2690 Part 2 outlines the technical criteria for hand-crafted burnt clay flat tiles designed for flat roof terracing. It details specifications including tile dimensions, physical characteristics such as water absorption and bending strength, sampling and testing procedures, as well as marking protocols to guarantee product reliability and performance. This code is primarily utilized by manufacturers, quality assurance personnel, and engineers engaged in tile production, inspection, and application within the Indian construction sector.

11Sections
56Clauses Indexed
AI Search Ready
1992Edition
Clay and Stabilized Soil Products for ConstructionCategory
Alternative search terms: handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 pdf free download, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 free download pdf, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992:1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992-1992 PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 (1992) PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 1992 edition PDF, handmade-burnt-clay-flat-roof-terracing-tiles-specifications-1992 edition 1992 PDF

What This Standard Covers

The 1992 edition of IS 2690 Part 2 outlines the technical criteria for hand-crafted burnt clay flat tiles designed for flat roof terracing. It details specifications including tile dimensions, physical characteristics such as water absorption and bending strength, sampling and testing procedures, as well as marking protocols to guarantee product reliability and performance. This code is primarily utilized by manufacturers, quality assurance personnel, and engineers engaged in tile production, inspection, and application within the Indian construction sector.

Who Uses This Standard

  • Structural and civil engineering professionals
  • Producers of construction materials
  • Quality assurance inspectors
  • Roof installation specialists
  • Building designers and architects
  • Distributors of construction supplies
  • Laboratory technicians for material testing

Key Topics Covered

Soil and raw material quality specifications
Tile size, shape uniformity, and allowable deviations
Permissible limits for tile warpage
Standards and methods for water absorption testing
Criteria and methods for measuring flexural strength
Sampling techniques for quality verification
Tile marking and identification standards
Specifications for testing equipment
Procedures for calculating and documenting test outcomes
Correlation with associated Indian Standards
Production considerations for handmade tiles
Certification and standard marking requirements

Table of Contents

1Scope and Application
2Referenced Standards and Technical Specifications
3Terminology and Definitions
4General Quality Requirements
5Dimensional Properties, Shape, Tolerances, and Warpage Limits
6Water Absorption Limits and Testing Procedures
7Flexural Strength Evaluation
8Sampling Procedures and Suitability Criteria
9Marking and Identification Requirements
Annex AList of Applicable Indian Standards
Annex BMethodology for Determining Flexural Strength

Popular Questions About IS 2690 PART 2

?What is the maximum allowable water absorption for hand-made burnt clay terracing tiles as per the standard?

According to IS 2690 Part 2, the water absorption by weight for hand-made burnt clay flat terracing tiles must not exceed 20%. This limit ensures that the tiles maintain durability and resist weathering effects. Testing for water absorption is conducted following IS 3495 (Part 2): 1992 procedures.

?How is the flexural strength of these terracing tiles measured and what is the minimum acceptable value?

The flexural strength test involves placing the tile on supports spaced at three-quarters of its length and applying a load perpendicular to this span at a controlled rate of 450 to 550 N per minute until the tile fails. The flexural strength is calculated using the formula: (15 × W × S) / (b × t²) in N/mm², where W is the breaking load in kilograms, S is the span in millimeters, b is the tile width, and t is the thickness. The minimum required flexural strength specified is 1.5 N/mm².

?What are the dimensional tolerance and warpage limits specified for hand-made terracing tiles?

Hand-made burnt clay terracing tiles must have uniform shapes and sizes with tolerances typically around ±3% of the nominal dimensions, although minor variations ranging from ±3 mm to ±5 mm can be acceptable given the manual manufacturing process. The maximum allowable warpage is limited to 2% of the tile dimension, ensuring tiles lie flat without twists, bends, or cracks.

?Which sampling methods are recommended under IS 2690 Part 2 to evaluate tile quality?

The sampling protocol for assessing the quality of hand-made terracing tiles follows the guidelines of IS 5454:1978, which covers sampling procedures for clay building bricks. Samples are randomly selected from production lots in quantities proportional to batch size to ensure representativeness. This method supports accurate quality assessment through physical and mechanical testing.

?How must hand-made burnt clay terracing tiles be marked to comply with the standard?

Each hand-made terracing tile must bear a clear and permanent marking that includes the manufacturer's identification or trademark and the symbol 'Il' to indicate it is handmade. The marking should cover no more than 5% of the tile's surface area. Optionally, tiles may display the BIS Standard Mark to signify adherence to the Indian Standards and quality control regulations.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 2690 PART 2. Get instant, clause-cited responses powered by our indexed library.