IS 48051978AI Search Enabled✦ AI Generated

Guide for construction of the brick kiln
1978 Edition

The 1978 edition of IS 4805 outlines detailed instructions for designing and erecting continuous, top-fed brick kilns fueled by coal and utilizing natural draught. It specifies parameters for kiln size, chamber capacity, trench construction, flue and chimney design, and site selection to promote efficient firing and high-quality brick production. This code serves as an indispensable reference for engineering and construction experts engaged in brick kiln development across India.

14Sections
32Clauses Indexed
AI Search Ready
1978Edition
Clay and Stabilized Soil Products for ConstructionCategory
Alternative search terms: guide-for-building-top-fed-coal-fired-brick-kilns-1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 pdf free download, guide-for-building-top-fed-coal-fired-brick-kilns-1978 free download pdf, guide-for-building-top-fed-coal-fired-brick-kilns-1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978:1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978-1978 PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 (1978) PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 1978 edition PDF, guide-for-building-top-fed-coal-fired-brick-kilns-1978 edition 1978 PDF

What This Standard Covers

The 1978 edition of IS 4805 outlines detailed instructions for designing and erecting continuous, top-fed brick kilns fueled by coal and utilizing natural draught. It specifies parameters for kiln size, chamber capacity, trench construction, flue and chimney design, and site selection to promote efficient firing and high-quality brick production. This code serves as an indispensable reference for engineering and construction experts engaged in brick kiln development across India.

Who Uses This Standard

  • Structural Engineers
  • Brick Production Specialists
  • Construction Supervisors
  • Industrial Process Engineers
  • Masonry-Focused Architects
  • Quality Assurance Inspectors
  • Environmental Safety Professionals

Key Topics Covered

Chamber dimensions and kiln capacity
Construction of trench floors and side walls
Specifications for flues and chimney design
Site evaluation including subsoil water and drainage
Recommended materials for kiln walls and flooring
Operation using natural airflow principles
Provision of access doors within kiln trenches
Thermal insulation methods
Drainage and terrain slope requirements
Maintenance practices and operational efficiency
Safety protocols and environmental considerations
Standardized kiln layout and configuration

Table of Contents

1Scope and General Overview

IS 4805 - 1978 (Reaffirmed 2002): Scope Highlights

  • Chimney Shape & Accessories (Clause 4.10):

    • Must conform to the profile shown in Fig. 3.
    • Installation requires two chimneys.
  • Flue Dimensions & Construction (Clause 4.8):

    • To be built as depicted in Fig. 2.
    • Size: 1.20 m by 0.90 m.
  • Material Requirements (Clause 2.5):

    • Mild steel sheet thickness ranges from 3 to 25 mm.
    • Base plate thickness: 25 mm or two welded plates of 12 mm each.
    • Brass bush diameter: 50 mm.
    • Brass washer: diameter 100 mm, thickness 12.5 mm.
    • Pin: diameter 25 mm, length 225 mm.

Key Dimensions Summary

ComponentSize/Thickness
Flue Dimensions1.20 m × 0.90 m
Mild Steel Sheet3 to 25 mm
Base Plate25 mm or 2 × 12 mm welded
Brass Bush50 mm diameter
Brass Washer100 mm diameter, 12.5 mm thick
Pin25 mm diameter, 225 mm length

Refer to Fig. 2 and Fig. 3 in IS 4805 for detailed drawings and assembly instructions.

2Required Site and Environmental Details

Essential Information for Designing Top-Fed Coal Brick Kilns (IS 4805)

Data to be Provided (Clause 2.1)

  • Subsoil water table level at the kiln location
  • Topography slope and natural drainage characteristics
  • Soil classification, with emphasis on expansive black cotton soil
  • Climatic parameters including temperature, humidity, and wind patterns
  • Proximity to residential areas and availability of communication links

Chimney Base Plate Material Specifications (Clause 2.5)

ComponentSpecification
Mild Steel SheetThickness between 3 and 25 mm
Chimney Base Plate25 mm thick or two 12 mm plates welded
Brass Bush Tread50 mm diameter
Brass Washer Thickness12.5 mm (diameter 100 mm)
Pin25 mm diameter, 225 mm length

Dimensions are in centimeters unless otherwise noted.


Notes:

  • Soil and drainage data inform foundation design.
  • Climatic conditions impact thermal performance.
  • Close proximity to habitation demands emission controls.

flowchart TD
    Site_Inspection --> Subsoil_Water_Level
    Site_Inspection --> Ground_Slope_and_Drainage
    Site_Inspection --> Soil_Type
    Site_Inspection --> Climate_Conditions
    Site_Inspection --> Nearby_Residences
    Subsoil_Water_Level & Ground_Slope_and_Drainage & Soil_Type & Climate_Conditions & Nearby_Residences --> Design_Inputs

This information guides the design of a durable and efficient kiln foundation and chimney system.

3Selecting Site & Ground Condition Requirements

Site Selection Criteria and Ground Conditions per IS 4805

Core Guidelines:

  • Subsoil Water Table:

    • Kiln trench floors must be positioned at least 3 m above the highest water table during rainy periods (Clause 3.2).
    • Trench floor elevation should not be more than 1 m lower than the ground surface.
  • Topography and Drainage:

    • Evaluate natural ground slope to prevent water pooling near the kiln (Clause 2.1b).
  • Soil Type:

    • Particular caution with black cotton soil due to its swelling properties (Clause 2.1c).
  • Trench Dimensions:

    • Trench height fixed at 2.25 m (Clause 4.2).
    • Side walls incorporate flues for chimney integration, with two flues per chamber (Clause 4.3).

Site Selection Checklist:

  • Seasonal subsoil water levels
  • Slope and drainage patterns
  • Soil bearing capacity and type
  • Climatic influences
  • Distance from populated areas and infrastructure

Floor Level Criteria:

CriterionRequirement
Minimum height above water table≥ 3 m
Maximum depth below ground≤ 1 m

Conceptual Site Diagram:

flowchart LR
    Ground_Surface --> Trench_Floor
    Trench_Floor -->|≥ 3 m above| Water_Table
    Ground_Surface -->|≤ 1 m below| Trench_Floor
    Soil_Type --> Black_Cotton?
    Black_Cotton? -->|Yes| Special_Foundation
    Black_Cotton? -->|No| Standard_Foundation

Summary: Position trench floors safely above water tables, assess soil properties carefully, and ensure natural drainage for stable kiln construction.

4Brick Kiln Construction Guidelines

IS 4805 Construction Guidelines for Brick Kilns

Construction Details:

  • Flue Dimensions:
    • Length: 1.20 m, Width: 0.90 m (Clause 4.8).
    • Constructed as per Fig. 2 (not included here).

Important Construction Considerations (Clause 2.1):

  • Subsoil water level measurements
  • Assessment of ground slope and drainage
  • Soil characteristics, especially expansive soils
  • Climatic data
  • Distance to inhabited zones and access routes

Additional Notes:

  • Kiln type: Top-fed, coal-fired, natural draught.
  • Thorough site evaluation is crucial for structural soundness and kiln efficiency.

Flue Dimension Summary:

ParameterMeasurement (m)
Flue Length1.20
Flue Width0.90

flowchart LR
    Site_Selection --> Soil_and_Water_Analysis
    Soil_and_Water_Analysis --> Slope_and_Drainage
    Slope_and_Drainage --> Climate_Factors
    Climate_Factors --> Kiln_Build
    Kiln_Build --> Flue_Construction[Flue Size 1.20 x 0.90 m]

This design facilitates effective airflow and combustion.

4.1Kiln Dimensions and Brick Capacity

Specifications for Kiln Size and Capacity (IS 4805)

  • Kiln Configuration: See Fig. 1 for typical bull's trench kiln with earth embankments.

  • Trench Height: Fixed at 2.25 m (Clause 4.2).

  • Large Capacity Kiln (Clause 4.1.1):

    • Chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 9.0 m
    • Capacity per chamber: 28,000 standard bricks
  • Small Capacity Kiln (Clause 4.1.2):

    • Chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 4.5 m
    • Capacity per chamber: 14,000 standard bricks
  • Flues per Chamber (Clause 4.3):

    • Large kiln: 2 flues (inner and outer walls)
    • Small kiln: 1 flue (outer wall only)

Dimension Summary Table

ParameterLarge CapacitySmall Capacity
Number of Chambers3030
Chamber Length (m)5.05.0
Trench Width (m)9.04.5
Trench Height (m)2.252.25
Bricks per Chamber28,00014,000
Flues per Chamber21

flowchart LR
    Trench_Height_2_25m --> Large_Kiln
    Trench_Height_2_25m --> Small_Kiln
    Large_Kiln --> Chambers_30
    Large_Kiln --> Length_5m
    Large_Kiln --> Width_9m
    Large_Kiln --> Capacity_28000
    Large_Kiln --> Flues_2
    Small_Kiln --> Chambers_30
    Small_Kiln --> Length_5m
    Small_Kiln --> Width_4_5m
    Small_Kiln --> Capacity_14000
    Small_Kiln --> Flues_1
4.2Trench Height and Floor Specifications

Specifications for Trench Height According to IS 4805

  • Trench Height: Uniformly set to 2.25 m for both large and small kilns (Clause 4.2).

  • Trench Floor Elevation (Clause 3.2):

    • Should be at least 3 m above the water table during rainy season.
    • Must not be more than 1 m below ground level.
  • Floor Surface:

    • Must be paved with burnt bricks laid on edge to ensure durability (Clause 4.5).
  • Access:

    • Sufficient number of access wickets to be provided (Clause 4.4).

Summary Table

ParameterSpecification
Trench Height2.25 m
Floor Elevation≥ 3 m above water table; ≤ 1 m below ground
Floor MaterialBurnt bricks laid on edge
Access ProvisionsAdequate wickets for easy entry

flowchart TD
    Ground_Level -->|Max 1 m below| Trench_Floor
    Trench_Floor -->|Min 3 m above| Water_Table
    Trench_Height_2_25m --> Side_Walls_With_Flues
    Trench_Floor --> Brick_Paved_Floor
    Trench_Height_2_25m --> Access_Wickets

This configuration supports structural strength and operational ease.

4.3Side Walls and Flue Construction

IS 4805 Guidance on Side Wall and Flue Construction

  • Side Wall Thickness:

    • Minimum of 60 cm (Clause 4.6).
  • Materials:

    • Preferably constructed from ordinary burnt bricks for durability and ease of maintenance.
    • Two flues per chamber for larger kilns (inner and outer walls).
    • Smaller kilns require only one flue on the outer wall (Clause 4.3).
  • Flue Dimensions:

    • Each flue measures 1.20 m by 0.90 m (Clause 4.8).
    • Construction follows Fig. 2 (not included here).
  • Trench Height:

    • Fixed at 2.25 m (Clause 4.2).
  • Chimneys:

    • Two chimneys per kiln required (Clause 4.10).
    • Chimney shape and attachments as per Fig. 3.

Summary Table

ElementSpecificationClause
Side Wall Thickness60 cm (burnt bricks)4.6
Flue Dimensions1.20 m × 0.90 m4.8
Trench Height2.25 m4.2
Flues per Chamber2 (large kiln), 1 (small kiln)4.3
Chimneys per Kiln24.10

flowchart TB
    Side_Wall_60cm --> Flue_1_20x0_90
    Flue --> Chimney_2_per_kiln
    Side_Wall_60cm --> Inner_Flue
    Side_Wall_60cm --> Outer_Flue
4.4Provision of Access Wickets

IS 4805 Specifications for Access Wickets

  • Clause 4.4: Ensure an adequate number of access wickets for convenient entry into trench sections.

  • Material and Construction (Clause 2.5):

    • Wickets constructed from mild steel sheets, thickness ranging 3–25 mm.
    • Base plates for chimneys: either 25 mm thick or two welded plates of 12 mm each.
    • Brass bush diameter: 50 mm.
    • Brass washer: diameter 100 mm, thickness 12.5 mm.
    • Pin: diameter 25 mm, length 225 mm.
    • Base plates are equipped with wheels (3B type) to enable mobility.
  • Dimensions:

    • All dimensions in centimeters unless stated otherwise.
    • Flue size remains 1.20 m × 0.90 m (Clause 4.8).

Access Wicket Components Summary

ComponentSize/ThicknessMaterial
Mild Steel Sheet3 to 25 mm thickMild Steel
Base Plate25 mm or 2×12 mm thickMild Steel
Brass Bush50 mm diameterBrass
Brass Washer100 mm diameter, 12.5 mm thickBrass
Pin25 mm diameter, 225 mm lengthSteel

graph LR
    MS_Sheet_Door --> Base_Plate_25mm
    Base_Plate_25mm --> Brass_Bush_50mm
    Brass_Bush_50mm --> Brass_Washer_100mm
    Brass_Washer_100mm --> Pin_25mm_225mm
    Base_Plate_25mm --> Wheels_3B

Summary: Wickets must be sturdy, correctly sized for easy access, and constructed using specified materials to ensure durability and functionality.

4.5Paving of Trench Floor

IS 4805 Recommendations for Trench Floor Paving

  • Floor Paving (Clause 4.5):

    • Trench floors should be paved with burnt bricks laid on edge to withstand thermal and mechanical stresses.
  • Floor Elevation (Clause 3.2):

    • Must be a minimum of 3 m above the subsoil water level during rainy periods.
    • Should not be deeper than 1 m below ground surface.
  • Trench Dimensions (Clauses 4.2 & 4.1.1):

    • Height: 2.25 m
    • Width: 9.0 m
    • Chamber length: 5.0 m
    • Number of chambers for large kiln: 30
    • Chamber capacity: 28,000 standard bricks

Trench Floor Paving Details

ParameterSpecification
Paving MaterialBurnt bricks
Brick OrientationVertical (on edge)
Floor Level≥ 3 m above water table, ≤ 1 m below ground
Trench Height2.25 m
Trench Width9.0 m
flowchart TB
    Subsoil_Water_Table -->|≥ 3 m above| Brick_Paved_Floor
    Brick_Paved_Floor --> Trench_Walls_With_Flues
    Trench_Walls_With_Flues --> Chimney_Placement

This ensures a durable floor that prevents water ingress and supports kiln operation effectively.

4.6Side Wall Thickness and Construction Materials

IS 4805 Guidelines on Side Wall Thickness and Materials

  • Wall Thickness:

    • Must be at least 60 cm thick (Clause 4.6).
  • Materials:

    • Preferably built using ordinary burnt bricks for enhanced durability and easier maintenance.
    • Unburnt bricks are permitted but have lower efficiency.
    • Walls should be plastered with mud mortar (Clause 4.7).
  • Insulation Option:

    • Walls can include a 25 cm cavity filled loosely with fine ash to improve thermal insulation (Clause 4.7 Note).
  • Additional Details:

    • Trench height remains 2.25 m (Clause 4.2).
    • Flues are incorporated on inner and outer walls for chimney installation (Clause 4.3).

Summary Table

ParameterSpecificationClause
Side Wall Thickness60 cm4.6
Brick TypeOrdinary burnt bricks preferred4.6
PlasteringMud mortar4.7
Insulation Cavity25 cm, optionally filled with fine ash4.7 Note
Trench Height2.25 m4.2

flowchart TD
    Side_Wall --> Thickness_60cm
    Side_Wall --> Material_Burnt_Bricks
    Side_Wall --> Plaster_Mud_Mortar
    Side_Wall --> Insulation_Cavity_25cm
    Insulation_Cavity_25cm --> Fine_Ash_Filling

This ensures side walls are strong, thermally efficient, and durable.

4.7Plastering and Thermal Insulation of Walls

IS 4805 Recommendations for Wall Plastering and Insulation

  • Wall Thickness:

    • Side walls should be 60 cm thick, constructed primarily from ordinary burnt bricks (Clause 4.6).
    • Unburnt bricks are allowed but not preferred for efficiency.
  • Plastering:

    • Walls must be coated with mud mortar to protect and provide breathability (Clause 4.7).
  • Thermal Insulation:

    • Walls may include a 25 cm cavity filled loosely with fine ash to enhance heat retention and reduce heat loss.

Summary Table

ParameterSpecification
Wall Thickness60 cm
Wall MaterialBurnt bricks (preferred)
PlasteringMud mortar
Insulation Cavity25 cm (optional)
Cavity FillingLoose fine ash

Notes:

  • The ash-filled cavity reduces thermal conductivity, improving kiln efficiency.
  • Mud plaster allows moisture regulation.

flowchart TD
    Wall_Construction --> Thick_Burnt_Brick_Wall
    Thick_Burnt_Brick_Wall --> Mud_Mortar_Plaster
    Thick_Burnt_Brick_Wall --> Optional_25cm_Cavity
    Optional_25cm_Cavity --> Loose_Fine_Ash
    Loose_Fine_Ash --> Improved_Insulation

This method balances durability, thermal performance, and moisture control.

4.8Flue Construction Specifications

IS 4805 Details on Flue Construction for Top-Fed Coal Brick Kilns

Key Points:

  • Flue Dimensions:
    • Length: 120 cm, Width: 90 cm (Clause 4.8).
  • Spacing Between Flues:
    • Centre-to-centre distance of 5.0 m (Clause 4.9).
  • Chimneys:
    • Two chimneys are mandatory (Clause 4.10).
  • Shape and Attachments:
    • Must match the configuration shown in Fig. 3 (not included), with rectangular form and proper draft features.

Construction Recommendations:

  • Build flues as per Fig. 2 with a rectangular cross-section.
  • Use fire-resistant bricks and mortar.
  • Internal surfaces should be smooth to reduce gas flow resistance.

Additional Notes:

  • Specified dimensions ensure sufficient natural draught.
  • Proper spacing prevents thermal interference between adjacent flues.

Summary Table:

ParameterValueUnit
Flue Size (Length × Width)120 × 90cm
Flue Spacing (C-C)5.0m
Number of Chimneys2-

flowchart LR
    Flue1 ---|5 m| Flue2
    Flue1 & Flue2 --> Chimneys
    Chimneys --> Natural_Draught

This design promotes effective combustion and heat flow in brick kiln operations.

4.9Spacing Between Flues

IS 4805 Specifications for Flue Size and Spacing

  • Flue Dimensions (Clause 4.8):

    • Width: 1.20 m
    • Height: 0.90 m
  • Flue Separation (Clause 4.9):

    • Maintain 5.0 m centre-to-centre distance between flues.
  • Chimney Requirements (Clause 4.10):

    • Two chimneys per kiln.
    • Chimney shapes and fittings follow Fig. 3 (not shown).
  • Material Specifications (Clause 2.5):

    • Mild steel sheet thickness: 3 to 25 mm.
    • Base plate: 25 mm thick or two welded plates of 12 mm.
    • Brass bush diameter: 50 mm.
    • Brass washer: 12.5 mm thickness, 100 mm diameter.
    • Pin size: 25 mm diameter, 225 mm length.

Summary Table

ParameterSpecification
Flue Size1.20 m × 0.90 m
Flue Spacing5.0 m (centre-to-centre)
Mild Steel Sheet Thickness3 to 25 mm
Base Plate Thickness25 mm or 2 × 12 mm welded
Brass Bush Diameter50 mm
Brass Washer12.5 mm thick, 100 mm dia
Pin Dimensions25 mm dia, 225 mm length
flowchart LR
    Flue_Size --> Flue_Spacing
    Flue_Spacing --> Chimneys_2
    Chimneys_2 --> Base_Plate
    Base_Plate --> Brass_Bush
    Brass_Bush --> Brass_Washer
    Brass_Washer --> Pin_Size

These parameters ensure structural soundness and proper spacing for flue and chimney systems.

4.10Chimney Configuration and Fittings

IS 4805: Chimney Shape and Fittings Overview

Chimney Shape (Clause 4.10 and Fig. 3)

  • Chimneys must adhere to the shape depicted in Fig. 3.
  • Each kiln requires two chimneys.
  • Attachments include base plates, brass bushes, washers, and pins as specified below.

Dimensions and Specifications

  • Flue size: 1.20 m × 0.90 m (Clause 4.8, Fig. 2).
  • Trench height: 2.25 m (Clause 4.2).
  • Base plate thickness: 25 mm or two welded plates of 12 mm each (Clause 2.5).
  • Mild steel sheet thickness: 3–25 mm (Clause 2.5).
  • Brass bush tread diameter: 50 mm.
  • Brass washer: 100 mm diameter, 12.5 mm thick.
  • Pin: 25 mm diameter, 225 mm length.

Attachment Summary (Clause 2.5)

ComponentSize/Thickness
Mild Steel Sheet3 to 25 mm
Base Plate25 mm or 2 × 12 mm welded
Brass Bush Tread50 mm
Brass Washer100 mm diameter, 12.5 mm thick
Pin25 mm diameter, 225 mm long

Flue and Chimney Arrangement (Clause 4.3)

  • Two flues per chamber: one on inner wall and one on outer wall.
  • Small kilns have one flue on outer wall only.

flowchart TD
    Chimney --> Base_Plate_25mm
    Base_Plate_25mm --> Brass_Bush_50mm
    Brass_Bush_50mm --> Brass_Washer_100mm_12_5mm
    Brass_Washer_100mm_12_5mm --> Pin_25mm_225mm
    Chimney --> Flue_1_20x0_90
    Flue_1_20x0_90 --> Inner_Wall_Flue
    Flue_1_20x0_90 --> Outer_Wall_Flue

This setup guarantees chimney stability and effective flue gas movement.

Popular Questions About IS 4805

?What are the recommended dimensions for large and small capacity brick kilns?

Recommended Dimensions for Brick Kilns (IS 4805):

  • Large Capacity Kiln:

    • Number of chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 9.0 m
    • Chamber capacity: 28,000 standard bricks
    • Trench height: 2.25 m
    • Flues: Two per chamber (one inner, one outer wall)
  • Small Capacity Kiln:

    • Number of chambers: 30
    • Chamber length: 5.0 m
    • Trench width: 4.5 m
    • Chamber capacity: 14,000 standard bricks
    • Trench height: 2.25 m
    • Flues: One per chamber (outer wall only)

These measurements are designed to optimize firing efficiency and structural integrity. The kiln shape and earth embankment details are illustrated in Fig. 1 of IS 4805.

Loading diagram...
?How should the kiln site be selected considering sub-soil water and drainage?

Site Selection Guidelines from IS 4805 (Clauses 2.1, 3.1 & 3.2):

  • Choose elevated terrain so that rainwater naturally drains away from the kiln, preventing waterlogging (Clause 3.1).

  • Determine the subsoil water table during rainy seasons.

    • The kiln trench floor must be at least 3 m above this water table to avoid seepage and foundation issues (Clause 3.2).
    • The floor should not be more than 1 m below ground surface to maintain stability.
  • Ensure the natural slope and drainage direct water away from the kiln area (Clause 2.1b).

  • Avoid black cotton soil or apply special foundation treatment because of its expansive nature (Clause 2.1c).


Summary Table:

ParameterRequirement
Ground ElevationHigh with natural drainage
Trench Floor Level≥ 3 m above subsoil water table
Maximum Floor Depth≤ 1 m below ground level
Soil TypeAvoid or treat expansive soils

Loading diagram...

This ensures stable foundations and effective kiln operation.

?What materials are specified for constructing the kiln walls and floors?

According to IS 4805, the materials specified for kiln construction are:

  • Side Walls:

    • Minimum thickness of 60 cm.
    • Built preferably with ordinary burnt bricks for enhanced durability and reduced maintenance.
    • Unburnt bricks are permitted but are less efficient.
  • Trench Floors:

    • No specific material mandated, but floors must be above the water table (minimum 3 m above subsoil water during rainy season) and not more than 1 m below ground level.

Summary Table

ComponentThicknessMaterialRemarks
Side Walls60 cmBurnt bricksPreferred for strength
Trench FloorN/ANot specifiedMust be above water table

This selection supports kiln stability and operational efficiency.

?How are the flues and chimneys designed to optimize natural draught?

Flue and Chimney Design for Enhanced Natural Draught (IS 4805)

  • Flues are rectangular, measuring 120 cm × 90 cm (Clause 4.8).
  • Constructed according to Fig. 2 specifications to ensure smooth internal surfaces for minimal airflow resistance.
  • Flues are spaced 5.0 m apart center-to-center (Clause 4.9) to prevent thermal interference.
  • Chimneys have shapes and attachments as per Fig. 3 (Clause 4.10) designed to enhance stack effect and draught.
  • Two chimneys are installed to maintain adequate ventilation.

Natural Draught Principle:

The pressure difference driving airflow is influenced by chimney height and temperature difference between flue gases and ambient air, mathematically expressed as:

[\Delta P = C \times h \times \frac{T_i - T_o}{T_o}]

Where:

  • (\Delta P) = draught pressure
  • (h) = chimney height
  • (T_i), (T_o) = absolute temperatures inside and outside the chimney
  • (C) = constant related to air density

Summary: IS 4805 ensures efficient natural draught by specifying flue size, spacing, chimney shape, and quantity to optimize airflow and combustion.

?What provisions are made for access within the kiln trenches?

Access Features in Brick Kiln Trenches (IS 4805)

  • Trenches have a height of 2.25 m (Clause 4.2).
  • Adequate numbers of access wickets (doors) are provided to allow workers convenient entry and exit at various trench locations (Clause 4.4).
  • The trench floor is elevated at least 3 m above the water table during rainy seasons, and not more than 1 m below ground level (Clause 3.2).
  • Floors are paved with burnt bricks laid on edge to facilitate movement and durability (Clause 4.5).

Summary: Kiln trenches are constructed to be 2.25 m tall, equipped with multiple access wickets for operational ease. Floors are brick-paved and properly elevated to maintain structural integrity and worker safety.