Firefighting vehicles and equipment - symbols for operator controls and other display
2006 Edition

The 2006 edition of IS 15682 establishes uniform graphical symbols for controls and display interfaces found in firefighting vehicles and equipment. It standardizes symbols representing functions such as pumps, tanks, electrical circuits, aerial devices, and pressure vessels, ensuring safe and effective operation. This code is vital for manufacturers, designers, and users of firefighting machinery in India.

13Sections
33Clauses Indexed
AI Search Ready
2006Edition
Fire FightingCategory
Alternative search terms: graphical-symbols-for-firefighting-vehicle-controls-2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 pdf free download, graphical-symbols-for-firefighting-vehicle-controls-2006 free download pdf, graphical-symbols-for-firefighting-vehicle-controls-2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006:2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006-2006 PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 (2006) PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 2006 edition PDF, graphical-symbols-for-firefighting-vehicle-controls-2006 edition 2006 PDF

What This Standard Covers

The 2006 edition of IS 15682 establishes uniform graphical symbols for controls and display interfaces found in firefighting vehicles and equipment. It standardizes symbols representing functions such as pumps, tanks, electrical circuits, aerial devices, and pressure vessels, ensuring safe and effective operation. This code is vital for manufacturers, designers, and users of firefighting machinery in India.

Who Uses This Standard

  • Manufacturers of firefighting vehicles
  • Design engineers for fire protection equipment
  • Fire service technical experts
  • Safety regulation officers
  • Control panel engineers
  • Fire brigade instructors
  • Equipment maintenance personnel

Key Topics Covered

Symbols for vehicle frame, engine, and chassis controls
Graphical representations of electrical circuitry
Symbols denoting tanks and pipework
Control and indicator symbols for fire pumps
Pressure vessel symbolization and monitoring
Symbols related to aerial firefighting apparatus
Icons for foam, water, and powder extinguishing agents
Winch and hose reel operation symbols
Symbol sets for monitoring and adjusting fire monitors
Legend definitions and scaling rules for symbols
Standardized orientation and application of symbols
Safety and operational display protocols

Table of Contents

1Scope and Overview of Symbol Categories

Overview of IS 15682 Scope and Symbol Classification

Scope (Clause 2.1):
Specifies geometric shapes and symbols for the following categories:

  • Frame, Engine, and Chassis
  • Electrical Circuits
  • Tanks and Piping
  • Pressure Vessels
  • Aerial Appliances
  • Other Miscellaneous Symbols

Representative Tables of Symbols

ClauseCategoryCommon Symbols / Functionality
3.1Frame, Engine, ChassisEngine start/stop, Minimum rotational speed (N_min), Jacking devices, Axle-locking system
3.5Tank and PipingWater and foam tank filling/draining, Tank heater, Fluid level indicators
3.8MiscellaneousCircuit status (open/closed), Winch operations, Deflector positions, Hose reel controls

Sample Symbols for Frame, Engine, and Chassis (Clause 3.1)

Serial No.FunctionSymbol
1Engine start(graphical icon)
2Engine stop(graphical icon)
5Minimum rotational speed (N_min)N min
8Jacking system(graphical icon)
15Axle-lock engaged(graphical icon)

Notes:

  • Symbols visually represent operational states or components for clarity.
  • Used for standardizing diagrams and controls on firefighting apparatus.
  • Detailed symbol illustrations and instructions are given in respective clauses.

flowchart TD
    A[Scope] --> B[Frame, Engine & Chassis]
    A --> C[Tanks & Piping]
    A --> D[Electrical Circuits]
    A --> E[Pressure Vessels]
    A --> F[Aerial Appliances]
    A --> G[Miscellaneous]

    B --> B1[Engine Start/Stop]
    B --> B2[Rotational Speed (N_min)]
    B --> B3[Jacking Systems]
    B --> B4[Axle Locking Mechanism]

    C --> C1[Water Tank Fill/Drain]
    C --> C2[Foam Concentrate Fill/Drain]
2Fundamental Requirements for Symbols and Designations

IS 15682: Essential Requirements for Symbols and Designations

This standard defines graphical symbols for various firefighting system components:

Tank and Piping Symbols (Clause 3.5)

FunctionSymbol Placeholder
Water tank filling(symbol not shown)
Foam concentrate filling(symbol not shown)
Water tank filling via pump(symbol not shown)
Foam concentrate filling via pump(symbol not shown)
Water tank draining(symbol not shown)
Foam concentrate draining(symbol not shown)
Premix tank draining(symbol not shown)
Water tank outlet(symbol not shown)
Foam concentrate outlet(symbol not shown)
Premix tank outlet(symbol not shown)
Tank heater(symbol not shown)
Fluid level indicator(symbol not shown)
Pressurized purging/piping(symbol not shown)

Fire Pump Symbols (Clause 3.4)

FunctionSymbol Placeholder
Fire pump intakeNumber 1
Fire pump delivery(symbol not shown)
Fire pump drain(symbol not shown)
Engage fire pump(symbol not shown)
Disengage fire pump(symbol not shown)
Air purge valve on fire pump(symbol not shown)
Fire pump by-pass(symbol not shown)

Miscellaneous Symbols (Clause 3.8)

FunctionSymbol Placeholder
Non-electrical circuit open(symbol not shown)
Non-electrical circuit closed(symbol not shown)
Winch operation(symbol not shown)
Winch-reel in(symbol not shown)
Winch-reel out(symbol not shown)
Deflector closed
Deflector open1

Important Notes:

  • Focus lies on symbol assignments rather than numerical formulas.
  • For structural and hydraulic calculations, refer to IS codes such as IS 456, IS 800, and other hydraulic design standards.

3Graphical Symbols for Firefighting Vehicles and Equipment Controls

IS 15682: Standardized Symbols for Firefighting Vehicle Controls and Displays

Key Highlights:

  • Consistent Symbol Scale (Clause 2.4): All graphical symbols must maintain uniform relative scaling consistent with the drawing scale, ensuring clarity.

  • Symbol Categories (Clause 3): Symbols cover controls including:

    • Water pump operations
    • Foam system valves
    • Ladder controls
    • Sirens and lighting
    • Other firefighting equipment interfaces

Example Symbol Usage:

CategoryDescriptionApplication Example
Pump ControlsStart/Stop, pressure settingsActivating water pumps
Foam SystemFoam concentrate valveManaging foam proportioning
Ladder OperationExtend, retract, rotateOperating aerial ladders
Siren & LightingSiren activation, beacon lightsEmergency signaling

Best Practices:

  • Employ standard symbols to avoid ambiguity during emergencies.
  • Ensure symbols are legible and uniformly sized across drawings.
  • Refer to annexures in IS 15682 for precise symbol designs.
flowchart LR
    A[Firefighting Vehicle] --> B[Operator Controls]
    B --> C{Control Types}
    C --> D[Water Pump]
    C --> E[Foam System]
    C --> F[Ladder]
    C --> G[Siren & Lights]

For detailed symbol shapes and dimensions, consult the complete IS 15682 standard.

3.1Symbols for Frame, Engine, and Chassis Components

IS 15682 - Frame, Engine, and Chassis Symbols (Clause 3.1)

This section specifies symbolic indicators for frame, engine, and chassis related controls and components:

Serial No.FunctionSymbol
1Engine start(symbol not shown)
2Engine stop(symbol selected)
3Continuous rotational adjustment(symbol not shown)
4Continuous linear adjustment(symbol not shown)
5Rotational speed (N_min)N_min
6Timer (clock)(symbol not shown)
7Auxiliary cooler(symbol not shown)
8Jacking system(symbol unselected)
9Vehicle stabilized on jacks(symbol not shown)
14House jacksÎ
15Axle-lock mechanism engaged(symbol not shown)
16Axle-lock mechanism disengaged(symbol not shown)

Notes:

  • Rotational speed (N_min) is a critical engine/chassis parameter.
  • Symbols for engine start/stop, jacking, and axle locking help in schematic standardization.
  • Continuous adjustments may be either rotational or linear.

Engineering Context:

  • Frame design must withstand dynamic stresses.
  • Monitoring engine rotational speed ensures operational safety.
  • Jacks and axle locks provide stability during operations or maintenance.

For detailed structural formulas, consult IS 800 (steel) or IS 456 (concrete) codes.


graph LR
  EngineStart --> EngineStop
  EngineStart --> RotationalSpeed[N_min]
  RotationalSpeed --> AuxiliaryCooler
  JackingSystems --> VehicleStabilized
  VehicleStabilized --> HouseJacks[Î]
  HouseJacks --> AxleLockOn
  HouseJacks --> AxleLockOff

This diagram illustrates the relationships among key symbols.

3.2Electrical Circuit Symbols in Firefighting Equipment

IS 15682 - Electrical Circuit Symbols (Clause 3.2 and 3.8)

Electrical Circuit Designations (Clause 3.2, Table 3.2)

Serial No.ComponentSymbol
1Locker light(symbol not shown)
2Additional hazard warning light+
3Reading light(symbol unselected)
4Beacon(symbol not shown)
5Siren(symbol not shown)
6Priority vehicle sound device(symbol not shown)
7Antenna(symbol not shown)
8Loudspeaker(symbol not shown)
9Intercom(symbol not shown)
10Adjustable working light(symbol not shown)
11Telescoping mast light(symbol not shown)

Miscellaneous Electrical Symbols (Clause 3.8, Table 3.8)

Serial No.FunctionSymbol
1Non-electrical circuit open(symbol not shown)
2Non-electrical circuit closed(symbol not shown)
3Winch(symbol not shown)
4Winch-reel in(symbol not shown)
5Winch-reel out(symbol not shown)
6Winch angle maximum(symbol not shown)
7Monitor lock(symbol not shown)
8Monitor unlock(symbol not shown)
9Water monitor(symbol not shown)
10Foam monitor(symbol not shown)
11Powder monitor(symbol not shown)
12Deflector closed
13Deflector open1
14Hose-reel(symbol not shown)

Summary:

  • Symbols provide a unified visual language for electrical and warning devices.
  • Standardization aids in quick identification and operation under emergency conditions.
3.3Symbols for Firefighting Expellants

IS 15682: Firefighting Expellant Symbols (Clause 3.3)

Expellant Types and their Symbols (Table 3.3)

Serial No.Expellant TypeSymbol Placeholder
1Water(not specified)
2Foam concentrate(not specified)
3Pre-mixed foam solution(not specified)
4Powder(not specified)

Additional Details:

  • Water serves as the primary extinguishing agent.
  • Foam concentrate and premix solutions are used for foam-based suppression.
  • Powder is commonly employed in dry chemical systems.

Typical Foam Solution Preparation Formula:

[ Q_f = C \times Q_w ] Where:

  • (Q_f): Foam concentrate flow rate
  • (C): Foam concentration ratio (e.g., 0.03 for 3%)
  • (Q_w): Water flow rate

Flow Overview:

flowchart LR
    Water -->|Mixed with| Foam_Concentrate
    Foam_Concentrate --> Pre_mix_Solution
    Pre_mix_Solution -->|Delivered to| Firefighting_System
    Powder -->|Direct Discharge| Firefighting_System

Refer to IS 15682 Tables 3.4, 3.5, and 3.6 for detailed fire pump, tank, piping, and pressure vessel symbols.

3.4Fire Pump Symbol Specifications

IS 15682 - Fire Pump Symbols and Details (Clause 3.4)

Fire Pump Types (Table 3.4)

Serial No.Pump TypeSymbol Placeholder
1General fire pumps(symbol not shown)
2Water fire pump(symbol not shown)
3Foam concentrate fire pump(symbol not shown)
4Pre-mix fire pump(symbol not shown)
5Priming fire pump(symbol not shown)

Fire Pump Components

Serial No.FunctionSymbol Placeholder
6Fire pump intakeNumber 1
7Fire pump delivery(symbol not shown)
8Drain for fire pump(symbol not shown)
9Engage fire pump(symbol not shown)
10Disengage fire pump(symbol not shown)
11Air purge valve on pump(symbol not shown)
12Fire pump by-pass(symbol not shown)

Tank and Piping Symbols (Clause 3.5)

Refer to previous section for tank filling, draining, and outlet symbols.


Design Considerations:

Symbols ensure standardized depiction of fire pump operations and connectivity.

3.5Tank and Piping Symbol Details

IS 15682 - Tank and Piping Symbols (Clause 3.5)

Key Symbol Designations

Serial No.FunctionSymbol Placeholder
1Water tank filling(symbol not shown)
2Foam concentrate tank filling(symbol not shown)
3Water tank filling via fire pump(symbol not shown)
4Foam concentrate filling via fire pump(symbol not shown)
5Water tank draining(symbol not shown)
6Foam concentrate draining(symbol not shown)
7Premix tank draining(symbol not shown)
8Water tank outlet(symbol not shown)
9Foam concentrate tank outlet(symbol not shown)
10Premix tank outlet(symbol not shown)
11Tank heater(symbol not shown)
12Fluid level indicator(symbol not shown)
13Pressurized purging/piping(symbol not shown)

Engineering Formulas:

  • Tank volume for cylindrical tanks: [ V = \pi r^2 h ]

  • Pressure loss in pipes (Darcy-Weisbach): [ \Delta P = f \frac{L}{D} \frac{\rho v^2}{2} ]

  • Filling time: [ t = \frac{V}{Q} ]

  • Pressure vessel design to follow IS 2825 with safety considerations.


Notes:

  • Fire pump connections and level indicators are critical for operations.
3.6Pressure Vessel Symbols and Guidelines

IS 15682 - Pressure Vessel Symbolization (Clause 3.6)

Symbol Assignments (Table 3.6)

Serial No.ComponentSymbol Placeholder
1Pressure vessel(symbol not shown)
2Pressurizing pressure vessel(symbol not shown)
3Pressure vessel outlet(symbol not shown)
4Pressure vessel drain(symbol not shown)
5Decompression device(symbol not shown)
6Pressure regulation valve(symbol not shown)
7Fluidizing device(symbol not shown)
8Purging valve(symbol not shown)
9Pressurized gas cylinder(symbol not shown)

Design Considerations:

  • Design pressure, temperature, and material per IS standards.
  • Shell thickness calculation for cylindrical vessels: [ t = \frac{P \times D}{2 \times \sigma \times \eta + P} ]
  • Corrosion allowance and joint efficiency are included.
  • Safety valves and drain provisions are mandatory.

graph LR
A[Pressure Vessel] --> B[Inlet / Pressurizing Vessel]
A --> C[Outlet]
A --> D[Drain]
A --> E[Decompression Valve]
A --> F[Pressure Regulation Valve]
A --> G[Purging Valve]

Refer IS 2825 for detailed pressure vessel design.

3.7Symbols for Aerial Firefighting Appliances

IS 15682 - Aerial Appliance Symbols and Controls (Clause 3.7)

Categories Covered:

  • Cage load capacity indicator
  • Turntable ladder controls:
    • Rotate clockwise/anticlockwise
    • Extend/retract ladder
    • Elevate/depress ladder
    • Ladder alignment
  • Hydraulic platform controls:
    • Rotate clockwise/anticlockwise
    • Extend/retract boom
    • Elevate/depress boom
  • Cage rotation controls:
    • Rotate clockwise/anticlockwise

Symbol Usage:

  • Each function corresponds to a specific graphical symbol as per Clause 3.7.
  • Symbols enable operators to quickly identify and operate controls safely.

Design Notes:

  • Cage load capacity must comply with safety standards.
  • Control movements should be smooth and reliable.
  • Symbols must be ergonomically displayed and conform to IS 15682.

Summary Table

FunctionDescriptionSymbol Reference
Cage load capacityMaximum permissible loadClause 3.7
Turntable ladderRotate, extend, elevateClause 3.7
Hydraulic platformRotate, extend, elevate boomClause 3.7
Cage rotationRotate clockwise/anticlockwiseClause 3.7

graph TD
    A[Control Panel] --> B(Rotate Ladder CW/ACW)
    A --> C(Extend Ladder)
    A --> D(Elevate/Depress Ladder)
    A --> E(Align Ladder)
    B --> F[Turntable Mechanism]
    C --> G[Extension Mechanism]
    D --> H[Elevation Mechanism]
    E --> I[Alignment Mechanism]

Refer to Clause 3.7 for complete graphical representations.

3.8Miscellaneous Symbols for Firefighting Equipment

IS 15682 - Miscellaneous Components and Symbols (Clause 3.8)

This section specifies designations and symbols for various auxiliary and mechanical components primarily related to non-electrical circuits.

Serial No.FunctionSymbol
1Non-electrical circuit open(not specified)
2Non-electrical circuit closed(not specified)
3Winch operation(not specified)
4Winch reel winding in(not specified)
5Winch reel winding out(not specified)
6Maximum winch angle(not specified)
7Monitor lock(not specified)
8Monitor unlock(not specified)
9Water monitor(not specified)
10Foam monitor(not specified)
11Powder monitor(not specified)
12Deflector closed
13Deflector open1
14Hose reel(not specified)
15Hose reel wind out(not specified)
16Hose reel wind in(not specified)
17Flushing(not specified)

Notes:

  • Symbol definitions are primarily for schematic clarity.
  • Only a few symbols like deflector positions are explicitly given.
  • These aid in standardizing control diagrams and equipment labeling.

flowchart LR
    A[Non-electrical Circuit] --> B{Open / Closed}
    B --> C[Open]
    B --> D[Closed]
    E[Winch Controls]

Use in conjunction with other clauses for comprehensive schematics.

4Legend and Symbol Scaling Requirements

IS 15682: Guidelines on Legend and Symbol Scaling (Clauses 2.3 & 2.4)

Legend Requirements (Clause 2.3):

  • All symbols must be clearly defined in an accompanying legend.
  • The legend should be straightforward and unambiguous.

Symbol Scale Requirements (Clause 2.4):

  • Symbols on any drawing must maintain the same relative scale.
  • Symbol sizes should correspond proportionally to the drawing scale to ensure readability.

Sample Symbol Table

Serial No.Symbol DescriptionUsage Example
1Cage load capacity indicatorLoad limit symbol
2Basic turntable ladder iconLadder representation
3Rotate clockwise arrowRotation direction
4Rotate anti-clockwise arrowOpposite rotation
10Hydraulic platform iconPlatform representation
17Cage rotation clockwise arrowCage movement
18Cage rotation anti-clockwise arrowCage movement opposite

Practical Advice:

  • For a drawing at 1:100 scale, a 10 mm symbol should be 20 mm at 1:50 scale.
  • Maintain uniform symbol proportions throughout the document.

flowchart LR
    A[Drawing Scale] --> B[Determine Symbol Size]
    B --> C{Is Relative Scale Consistent?}
    C -->|Yes| D[Apply Uniform Scaling]
    C -->|No| E[Adjust Symbols]
    D --> F[Add Clear Legend]

Summary:

  • Always define symbols clearly.
  • Ensure consistent sizing relative to scale.
  • Utilize IS 15682 tables for reference.
5Guidance on Application and Usage

IS 15682: Recommendations for Symbol Use and Application

The standard supports the consistent design and operation of firefighting equipment through standardized symbols.

Key Tables Include:

Miscellaneous Controls (Clause 3.8)

Serial No.FunctionSymbol
1Non-electrical circuit open(symbol not shown)
2Non-electrical circuit closed(symbol not shown)
3Winch(symbol not shown)
6Maximum winch angle(symbol not shown)
9Water monitor(symbol not shown)
10Foam monitor(symbol not shown)
12Deflector closed
13Deflector open1

Tank and Piping (Clause 3.5)

Serial No.FunctionSymbol
1Water tank fill(symbol not shown)
2Foam concentrate fill(symbol not shown)
5Water tank drain(symbol not shown)
12Fluid level indicator(symbol not shown)

Aerial Appliances (Clause 3.7)

Serial No.FunctionSymbol
2Turntable ladder(symbol not shown)
3Rotate clockwise(symbol not shown)
5Extend ladder(symbol not shown)
10Hydraulic platform(symbol not shown)
17Cage rotation clockwise4

Frame, Engine, and Chassis (Clause 3.1)

Serial No.FunctionSymbol
1Engine start(symbol not shown)
2Engine stop(symbol selected)
5Rotational speed (N_min)N_min
15Axle-lock engaged(symbol not shown)

Usage Suggestions:

  • Employ standardized symbols for clear communication in design and operation.
  • Ensure symbols are used consistently across documentation and equipment interfaces.

Popular Questions About IS 15682

?What are the standardized symbols for different types of fire pumps under IS 15682?

Clause 3.4 of IS 15682 (2006) defines uniform symbols for various fire pump types used in firefighting vehicles and apparatus. These include general fire pumps, water pumps, foam concentrate pumps, pre-mix pumps, and priming pumps. Specific symbols also represent pump functions such as intake (noted as '1'), delivery, drainage, engagement, disengagement, air purge valves, and by-pass lines. These standardized icons facilitate clear recognition and safe control panel operation. For precise graphical symbols, refer to the official IS 15682 documentation.

?How does IS 15682 define symbols for tanks and piping in firefighting vehicles?

IS 15682 specifies graphical symbols to represent tanks and piping components within firefighting vehicles. Tanks, such as water and foam concentrate reservoirs, are depicted with simple geometric shapes—rectangles or cylinders—labeled by content type. Piping is illustrated using lines with directional arrows to indicate flow. Valves and pumps have distinct standard icons to ensure clear and unambiguous understanding on schematics and control panels. This standardization promotes uniformity, aiding operators in emergency situations. Detailed symbol shapes are available within the IS 15682 standard.

?Are there specific symbols for electrical circuits and warning lights in firefighting equipment?

Yes, IS 15682 includes designated symbols for electrical circuits and warning lights within firefighting vehicle controls. Examples cover locker lights, additional hazard warning lights (symbolized by a plus sign), reading lights, beacons, sirens, priority vehicle sound devices, antennas, loudspeakers, intercoms, adjustable working lights, and telescoping mast lights. These symbols are standardized to ensure consistent identification and operation across firefighting equipment, enhancing safety and ease of use. Exact graphical representations can be found in the detailed tables of IS 15682.

?How should symbols be scaled and oriented according to this standard?

IS 15682 mandates that all symbols on a given drawing must maintain the same relative scaling consistent with the overall drawing scale, ensuring proportionality and clarity (Clause 2.4). Symbols should be reproducible by hand or machine, featuring simple, clear designs (Clause 2.2). Each symbol's meaning must be explicitly explained in a legend (Clause 2.3) to avoid ambiguity. While the standard does not explicitly prescribe orientation, symbols should be presented in a way that preserves clarity and conforms to established firefighting equipment conventions.

?What symbols are used for aerial appliances like ladders and hydraulic platforms?

IS 15682 Clause 3.7 defines graphical symbols for aerial firefighting equipment controls, including turntable ladders and hydraulic platforms. Symbols represent operations such as clockwise and anticlockwise rotation, extension and retraction, elevation and depression, and alignment for ladders and booms. Cage carrying capacity is also indicated with a specific symbol. These symbols help operators identify and manage aerial appliance functions safely and efficiently. The standard ensures all symbols are scaled uniformly for consistency on control panels.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 15682. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required