IS 9471985AI Search Enabled✦ AI Generated

Functional Requirements for Towing Tender for Trailer Fire Pump for Fire Brigade Use
1985 Edition

The 1985 standard delineates the operational criteria for towing tenders tasked with transporting sizable trailer fire pumps utilized by fire brigades. It encompasses crucial factors such as design parameters, materials, craftsmanship, accessories, and safety provisions to guarantee dependable and efficient firefighting performance. This specification serves manufacturers, fire department officials, and engineers engaged in the design, acquisition, and upkeep of firefighting towing tenders.

8Sections
118Clauses Indexed
AI Search Ready
1985Edition
Fire FightingCategory
Alternative search terms: functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 pdf free download, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 free download pdf, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985:1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985-1985 PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 (1985) PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 1985 edition PDF, functional-specifications-for-towing-tenders-of-trailer-fire-pumps-1985 edition 1985 PDF

What This Standard Covers

The 1985 standard delineates the operational criteria for towing tenders tasked with transporting sizable trailer fire pumps utilized by fire brigades. It encompasses crucial factors such as design parameters, materials, craftsmanship, accessories, and safety provisions to guarantee dependable and efficient firefighting performance. This specification serves manufacturers, fire department officials, and engineers engaged in the design, acquisition, and upkeep of firefighting towing tenders.

Who Uses This Standard

  • Manufacturers of firefighting vehicles
  • Procurement personnel in fire services
  • Engineers specializing in fire safety systems
  • Automotive design engineers for emergency vehicles
  • Technicians maintaining firefighting apparatus
  • Managers overseeing fire service vehicle fleets
  • Officials ensuring regulatory compliance

Key Topics Covered

Design and structural construction criteria
Selection and treatment of materials
Standards for workmanship and surface finish
Stability metrics and dimensional constraints
Electrical equipment and system requirements
Necessary accessories and fire equipment
Marking, labeling, and identification protocols
Safety components including handrails and slip-resistant steps
Provisioning for portable pump transport
Lighting and signaling device specifications
Design of storage lockers and compartments
Guidelines for operation manuals and maintenance

Table of Contents

1Scope and Overview

This section defines the range and primary specifications for fire brigade towing tenders, detailing required equipment, dimensions, and relevant Indian Standards for individual components like hoses, ladders, and extinguishers. It includes typical quantities of equipment supplied and references IS codes governing each item to ensure uniformity and compliance.

2Fundamental Requirements

General criteria concerning materials, design, workmanship, finishing, and outfitting of towing tenders for large trailer fire pumps. It includes tables listing essential equipment quantities and their corresponding IS references to ensure readiness and standardization.

3Materials: Selection and Treatment

Specifies the selection criteria for materials used in the construction of towing tenders and their treatment processes to enhance durability and resistance. Emphasizes compliance with IS materials standards and outlines protective coatings, corrosion resistance, and mechanical strength requirements.

4Design and Fabrication

Details design parameters and construction methods including equipment specifications, necessary fittings, and operational tools. Highlights design features such as lubrication points and structural elements crucial for functionality and safety.

5Craftsmanship and Surface Treatment

Addresses quality of workmanship ensuring smooth finishes and absence of defects. Specifies painting standards including color codes and durability requirements. Also covers stability requirements ensuring the tender remains secure on inclined surfaces.

6Accessories and Firefighting Equipment

Lists mandatory electrical accessories such as lighting, signaling devices, sirens, and safety equipment including breathing apparatus and hand tools. Details quantity, type, and IS code references for all items.

7Identification and Marking

Outlines the requirements for labeling all equipment with manufacturer details, IS code numbers, capacity, and manufacturing date. Marks must be legible and durable to maintain traceability and safety compliance.

Appendix ARecommended Tools and Firefighting Apparatus Inventory

A comprehensive list of tools, hoses, strainers, extinguishers, and other equipment with specified quantities and corresponding IS standards to aid procurement and maintenance.

Popular Questions About IS 947

?What are the maximum allowed dimensions for towing tenders as per the standard?

The standard specifies that towing tenders should not exceed a wheelbase of 3600 mm, have a turning circle no greater than 16 meters, and maintain a minimum ground clearance of 230 mm. These size limits ensure maneuverability and operational effectiveness during firefighting missions.

?Which materials are recommended for constructing towing tenders?

The towing tenders should be built using metal constructions, particularly pressed steel sections, to provide adequate strength and stiffness. The cab and storage lockers are to be made of metal and designed to be lightweight yet robust enough to withstand operational stresses, including towing loads and braking forces on slopes.

?What electrical components and safety features must be included according to the regulation?

Mandatory electrical accessories include a 250 mm diameter hand-operated fire bell mounted externally, headlamps, fog lamps, reversing lights, amber blinkers, illuminated trafficators, windshield wipers and washers, battery-operated siren, adjustable search and spotlights, inspection lamps, tail lamps, and instrument panel illumination. Safety features require independent fuses for key circuits, accessible fuse boxes with spares, single-pole wiring protected against exposure, and use of conduits where necessary.

?How does the standard ensure stability for towing tenders when carrying full load?

Though not explicitly specifying detailed stability criteria, the standard enforces stability through constraints such as a maximum payload of 5,000 kg, minimum engine power of 65 kW, capability to start on a 1 in 4 slope, effective braking within prescribed distances and gradients, and dimensional limits on wheelbase and turning radius. These collectively assure safe handling and stability under operational conditions.

?What provisions does the standard make for storage compartments and carrying portable pumps?

The towing tender must have a dedicated compartment at the rear for carrying a portable pump conforming to IS 942-1982 with a capacity of 275 liters per minute. This compartment should feature a hinged door opening outward for easy access. Additionally, the appliance should carry a 7.5-meter extension ladder and be capable of towing the trailer fire pump, with driver cab instrumentation including cooling water gauges and lubrication system indicators.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 947. Get instant, clause-cited responses powered by our indexed library.