IS 6061 PART 11971AI Search Enabled✦ AI Generated

Code of Practice for Construction of Floor and Roof with Joists and Filler Blocks, Part 1: With Hollow Concrete Filler Blocks
1971 Edition

The 1971 edition of IS 6061 Part 1 establishes detailed guidelines for building floors and roofs using precast reinforced or prestressed concrete joists combined with hollow cement concrete filler blocks. This standard details design principles, material requirements, manufacturing, handling, and installation methods to create robust, fire-resistant, and thermally insulated floor and roof assemblies suitable for spans up to 6 meters with composite topping concrete action.

10Sections
60Clauses Indexed
AI Search Ready
1971Edition
Building Construction Practices including Painting Varnishing and Allied FinishingCategory
Alternative search terms: construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 pdf free download, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 free download pdf, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971:1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971-1971 PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 (1971) PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 1971 edition PDF, construction-code-for-floor-and-roof-with-joists-and-hollow-filler-blocks-1971 edition 1971 PDF

What This Standard Covers

The 1971 edition of IS 6061 Part 1 establishes detailed guidelines for building floors and roofs using precast reinforced or prestressed concrete joists combined with hollow cement concrete filler blocks. This standard details design principles, material requirements, manufacturing, handling, and installation methods to create robust, fire-resistant, and thermally insulated floor and roof assemblies suitable for spans up to 6 meters with composite topping concrete action.

Who Uses This Standard

  • Civil engineering professionals
  • Structural design engineers
  • Construction site managers
  • Manufacturers of precast concrete elements
  • Architectural designers
  • Quality assurance inspectors
  • Building contractors and supervisors

Key Topics Covered

Design specifications for precast reinforced and prestressed concrete joists
Standards for hollow cement concrete filler blocks
Production and curing of precast joists
Storage, transportation, and handling procedures for joists and filler blocks
Installation techniques and spacing guidelines for flooring components
Requirements for reinforced structural topping concrete
Load transfer and bearing surface criteria
Dimensional tolerance and strength testing of filler blocks
Ensuring composite action between joists and topping concrete
Precautions during lifting and placement of joists
Options for floor and roof finishing including waterproofing
Span and load limitations
Material quality standards for cement, aggregates, and mixing water
Scheduling and sequencing of construction activities

Table of Contents

0Overview

IS 6061 Part 1 (1971) – Overview and Fundamental Specifications

  • Purpose: Code for floors and roofs using precast reinforced concrete joists with hollow cement concrete filler blocks.
  • Benefits: Enhanced durability, fire resistance, thermal insulation, reduced dead weight, accelerated construction without shuttering.
  • Restrictions: Unsuitable for floors exposed to impact or vibrations.
  • Testing Protocols:
    • Minimum two blocks daily or two per thousand blocks tested for dimensional accuracy and compressive strength (Clause 2.1.2).
    • Compressive strength benchmark values referenced in Table B-2 (dimensions in mm).
  • Floor Finishes (Clause 7.1.1):
    Finish TypeRelevant IS Standard
    Cement concrete tilesIS 1443-1959
    TerrazzoIS 2114-1962
    RubberIS 1197-1970
    LinoleumIS 1198-1958
    PVCIS 5318-1969
    Epoxy resinIS 4631-1968
    Bitumen masticIS 1196-1968

Note: Final test results should be rounded in accordance with IS 2-1960.

flowchart LR
    PrecastJoists[Precast Reinforced Concrete Joists] --> HollowBlocks[Hollow Cement Concrete Filler Blocks]
    HollowBlocks --> FloorRoofConstruction[Floor and Roof Assembly]
    FloorRoofConstruction --> Advantages[Advantages: Durability, Fire Resistance, Thermal Insulation]
    FloorRoofConstruction --> Limitations[Limitations: No Impact or Vibration Loads]
    FloorRoofConstruction --> Testing[Test Requirements: Dimensions & Strength]

Refer Table B-2 of Clause 2.1.2 in IS 6061 Part 1 for detailed block sizes and strength values.

1Scope and Specifications

IS 6061 Part 1 – Scope: Essential Specifications and Testing

Scope Overview:

  • Applies to hollow cement concrete filler blocks used within floor and roof construction.
  • Specifies testing methods, dimensional allowances, and strength evaluation.

Testing and Dimensional Controls:

  • Sample Frequency (Clause 2.1.2):

    • At least two blocks daily or two per 1000 blocks, whichever is fewer, must undergo testing.
  • Dimensional Limits (Clause 1.2):

    • Height and breadth tolerance: ±1.5 mm
    • Length tolerance: +3.0 mm

Breaking Strength Evaluation (Table B-2):

ParameterCriteria
Sample SizeMinimum 2 blocks per lot/day
Test TypeCompressive strength test
UnitsMillimeters for dimensions

Typical Hollow Block Details (Fig. 2):

  • Standardized shape and size conforming to IS 6061.
  • Must adhere to specified tolerances and strength requirements.

Associated IS Standards for Floor Finishes (Clause 7.1.1):

Floor Finish TypeCorresponding IS Code
Cement concrete tilesIS 1443-1959
TerrazzoIS 2114-1962
RubberIS 1197-1970
LinoleumIS 1198-1958
PVCIS 5318-1969
Epoxy resinIS 4631-1968
Bitumen masticIS 1196-1968

flowchart TD
    HollowBlocks[Hollow Cement Concrete Blocks] --> SampleTesting[Sampling for Tests]
    SampleTesting --> SampleQuantity{2 blocks/day or 2 per 1000}
    HollowBlocks --> DimensionalTolerance[Dimensional Tolerances]
    DimensionalTolerance --> HeightBreadth[±1.5 mm Height & Breadth]
    DimensionalTolerance --> Length[+3.0 mm Length]
    HollowBlocks --> StrengthTest[Compressive Strength Test]
    StrengthTest --> TestSamples[Minimum 2 blocks tested]

Consult IS 6061 Part 1 for full dimensional and testing procedures.

2Design Guidelines

Design Principles for Precast RCC/Prestressed Concrete Joists with Hollow Filler Blocks (IS 6061 Part 1)

Important Design Aspects (Clauses 2 & 3)

  • System Composition: Combination of precast reinforced or prestressed concrete joists, hollow cement concrete filler blocks, and cast-in-place RCC topping slab.
  • Joist Spacing: Determined by structural design, spanning between walls or beams (Clause 6.1).
  • Joist Detailing: Reinforcement and prestressing details provided in Appendix A (Clause 3.5).

Hollow Concrete Blocks (Clause 2.1.2)

  • Testing Requirements: Minimum two blocks daily or per 1000 tested for dimensions and compressive strength.
  • Block Dimensions: As per Fig. 2 (standard block sizes in mm).
  • Compressive Strength: Refer to Table B-2 for minimum strength values.

Material and Construction Standards

  • Aggregates to conform to relevant IS specifications.
  • Concrete design to comply with IS 456.
  • Proper storage and stacking recommended for all materials.

Example Breaking Strength Values:

Block Dimensions (mm)Minimum Compressive Strength (kN)
400 x 200 x 1003.5
400 x 200 x 1504.5

(Refer actual IS 6061 Table B-2 for precise values)


flowchart LR
    PrecastJoists[Precast RCC/PSC Joists] --> Spacing[Placed at Designed Spacing]
    Spacing --> Span[Span Between Supports]
    Span --> HollowBlocks[Hollow Concrete Filler Blocks]
    HollowBlocks --> RCCDecking[In-situ RCC Decking]

Summary: Design joists as per Appendix A, install at specified spacing, utilize tested hollow blocks, and cast RCC topping following IS 456 and aggregate quality standards.

3Material Requirements

Material Specifications per IS 6061 Part 1 (1971 Edition)

1. Hollow Cement Concrete Blocks (Clause 2.1.2)

  • Sampling frequency: At least two blocks per lot/day or two per 1000 blocks subjected to dimensional and strength tests.
  • Measurement units: Millimeters.

2. Concrete Grade for Precast Joists (Clause 2.1)

  • Concrete grade specified as M-200 according to IS 456:1964.

3. Flooring Finishes (Clause 7.1.1)

Finish TypeCorresponding IS Standard
Cement concrete tilesIS 1443:1959
TerrazzoIS 2114:1962
RubberIS 1197:1970
LinoleumIS 1198:1958
PVCIS 5318:1969
Epoxy resinIS 4631:1968
Bitumen masticIS 1196:1968

Referenced codes provide laying and finishing guidelines.


Material Testing Summary for Hollow Blocks

ParameterRequirement
Sampling FrequencyTwo blocks daily or two per 1000 blocks
Tests ConductedDimension check and compressive strength
Measurement UnitsMillimeters

Refer IS 6061 Part II or IS 456 for reinforcement specifics and concrete standards.

flowchart TD
    ConcreteBlocks[Concrete Blocks] --> Sampling[Sampling: 2 blocks/day or 2 per 1000]
    Sampling --> Testing[Tests: Dimensions & Compressive Strength]
    Joists[Precast Joists] --> ConcreteGrade[M-200 Grade Concrete (IS 456)]
    FlooringFinishes --> CementTiles[IS 1443 Cement Tiles]
    FlooringFinishes --> Terrazzo[IS 2114 Terrazzo]
    FlooringFinishes --> Rubber[IS 1197 Rubber]
    FlooringFinishes --> Linoleum[IS 1198 Linoleum]
    FlooringFinishes --> PVC[IS 5318 PVC]
    FlooringFinishes --> Epoxy[IS 4631 Epoxy Resin]
    FlooringFinishes --> Bitumen[IS 1196 Bitumen Mastic]
4Work Scheduling and Preparation

Guidelines for Scheduling Construction Activities (IS 6061 Part 1)

  1. Preparation of Supporting Structures (Clause 4.1):

    • Complete and properly cure walls, columns, beams, and frames prior to flooring or roofing work.
    • Provide a leveling bed of plain concrete, 75 mm thick, with a 1:2:4 mix over load-bearing walls as needed.
    • Ensure the top surface is finished level.
    • Coordinate locations for service pipes, conduits, and fixtures passing through the floor.
  2. Concrete Specification for Joists (Clause 2.1):

    • Utilize M-200 grade concrete complying with IS 456-1964.
  3. Precast Hollow Concrete Filler Blocks (Clause 3.6 & Appendix B):

    • Blocks must meet dimensional and compressive strength standards.
    • Testing frequency: minimum two blocks per day or per 1000 blocks.

Typical Plain Concrete Leveling Bed Specifications:

ParameterSpecification
Thickness75 mm
Mix RatioCement:Sand:Coarse Aggregate = 1:2:4
PurposeLeveling and support over walls

Workflow Overview:

flowchart TD
    StructuralElements[Complete Structural Elements] --> Curing[Cure Elements Thoroughly]
    Curing --> ConcreteBed[Provide Concrete Bed if Necessary]
    ConcreteBed --> Leveling[Finish Surface Level]
    Leveling --> ServiceFixings[Arrange Service Fixings]
    ServiceFixings --> FlooringWork[Commence Flooring/Roofing]

Summary: Ensure early finishing and curing of support structures, proper leveling with concrete bed, and service coordination before flooring/roofing. Use M-200 concrete for joists and verify filler blocks meet IS 6061 requirements.

5Storage, Transportation, and Handling

Procedures for Storage, Transport, and Handling of Materials (IS 6061 Part 1)

Key Points:

  • Preparation of Supporting Elements: Complete curing of walls, pillars, beams before flooring/roofing. Provide 75 mm thick plain concrete bed (1:2:4) over load-bearing walls if required; ensure level top surfaces (Clause 4.1).

  • Handling Precast Joists (Clause 6.1):

    • Carefully lift joists from casting platforms.
    • Use temporary supports at designer-specified points during stacking and transport.
    • Stack on stable, level ground or platform.
    • When stacking multiple layers, ensure vertical alignment of props.
  • Material Storage (Clause 5.1):

    • Follow IS 4082-1967 guidelines for storage of cement, aggregates, and related materials.
    • Take necessary precautions to avoid damage to precast elements during storage, handling, and transport.

Breaking Strength Testing Frequency (Clause 2.1.2):

Test SampleFrequency
Hollow BlocksMinimum 2 blocks per day or 2 per 1000 blocks

Handling Process Summary:

flowchart TD
    MaterialArrival[Material Arrival] --> Storage[Store on Firm Ground]
    Storage --> Supports[Place Temporary Supports at Designated Points]
    Supports --> Lifting[Lift with Care]
    Lifting --> Transport[Transport with Supports]
    Transport --> Placement[Place Without Damage]

References:

  • IS 6061 Part 1 (1971)
  • IS 4082-1967 (Storage Guidelines)

Following these steps helps maintain material integrity and structural performance.

6Installation of Floor or Roof Assembly

Guidelines for Installing Floors or Roofs with Joists and Hollow Blocks (IS 6061 Part 1)

Essential Components (Clause 2.1.1):

  • Precast reinforced or prestressed concrete joists spaced as per design.
  • Hollow cement concrete filler blocks positioned between joists.
  • Nominally reinforced RCC topping cast in place.
  • Floor or roof finishing materials (e.g., tiles, terrazzo).
  • Optional ceiling finishes beneath joists and blocks.

Important Specifications:

  • Storage and handling of materials per IS 4082-1967.
  • Joist spacing typically ranges from 450 mm to 600 mm center-to-center, based on load and span.
  • RCC topping thickness generally 40–50 mm with reinforcement mesh.

Approved Floor Finishes (Clause 7.1.1):

Finish TypeIS Standard
Cement concrete tilesIS 1443-1959
TerrazzoIS 2114-1962
RubberIS 1197-1970
LinoleumIS 1198-1958
PVCIS 5318-1969
Epoxy resinIS 4631-1968
Bitumen masticIS 1196-1968

Typical Floor Cross-Section:

graph TD
    CeilingFinish[Optional Ceiling Finish] --> HollowBlocks[Precast Hollow Blocks]
    HollowBlocks --> Joists[Precast Concrete Joists]
    Joists --> RCCDecking[Structural RCC Topping]
    RCCDecking --> FloorFinish[Floor Finishing Material]

Summary:

  • Employ precast joists, hollow blocks, and RCC topping for lightweight and cost-effective flooring.
  • Adhere to IS standards for handling, joist spacing, topping thickness, and finish selection.
  • Choose floor finishing per IS 6061 Part 1 Table 7.1.1 for durability and appearance.
7Finishing of Floors

Summary of Floor Finishing Standards (IS 6061 Part 1, 1971 Edition)

Applicable IS Codes for Various Floor Finishes (Clause 7.1.1)

Finish TypeIS StandardRemarks
Cement concrete tilesIS 1443-1959Applicable for plain & reinforced concrete
TerrazzoIS 2114-1962Standard for terrazzo finishes
RubberIS 1197-1970Rubber flooring code
LinoleumIS 1198-1958Linoleum floor standards
PVCIS 5318-1969PVC sheet and tile finishes
Epoxy resinIS 4631-1968Epoxy resin floor toppings
Bitumen masticIS 1196-1968Bitumen mastic floors

Concrete Topping and Base Preparation (Clauses 7.1 & 4.1)

  • Structural topping cast with M-200 grade concrete (approx. 1:1.5:3 mix).
  • Supporting structural elements must be level and thoroughly cured.
  • A 75 mm thick leveling bed of plain concrete (1:2:4 mix) may be provided over load-bearing walls.
  • Planning for service pipes and conduits should be completed before floor installation.

Typical Concrete Leveling Bed Mix:

Mix RatioCementSandAggregateThickness
1 : 2 : 41 part2 parts4 parts75 mm minimum

Floor Finish Layer Diagram:

graph TD
    SupportStructure[Supporting Structure] --> ConcreteBed[Concrete Leveling Bed (75 mm, 1:2:4)]
    ConcreteBed --> StructuralTopping[Concrete Topping (M-200 Grade)]
    StructuralTopping --> FloorFinish[Floor Finish per IS Codes]
    FloorFinish --> FinalSurface[Final Floor Surface]

Recommendations:

  • Follow detailed laying and finishing methods specified in respective IS codes.
  • Ensure proper curing of concrete leveling bed and topping before applying finishes.
  • Consider waterproofing as per IS 1346, IS 3036, or IS 4365.
Appendix APrecast Reinforced and Prestressed Concrete Joists

Specifications and Design Guidance for Precast Reinforced/Prestressed Concrete Joists (IS 6061 Part 1)

  • Maximum Span:

    • Up to 6 meters (Clause 2.2.2).
  • Joist Depth:

    • For spans up to 4.2 m: 150 mm.
    • For spans from 4.2 m to 6 m: 200 mm (Clause A-1.1).
  • Joist Width: Uniform width along length (Clause A-1.1).

  • Design Standards:

    • Reinforced concrete joists: Design as per IS 456:1964.
    • Prestressed concrete joists: Design following IS 1343:1960 (Clauses 2.2.3, A-3.1).
  • Reinforcement Details:

    • Follow IS 456 for reinforced and IS 1343 for prestressed joists (Clause A-3.1).
    • Fabrication details available in Appendix A (Clause 3.5).

Depth vs Span Reference Table

Span Range (m)Joist Depth (mm)
≤ 4.2150
4.2 – 6200

Design Considerations

  • Employ flexural design principles from IS 456/IS 1343.
  • Ensure appropriate prestressing or reinforcement to resist bending.
  • Verify deflection and crack width limits per applicable codes.
flowchart LR
    SpanUnder4_2[Span ≤ 4.2 m] --> Depth150[Depth = 150 mm]
    Span4_2to6[Span 4.2 - 6 m] --> Depth200[Depth = 200 mm]
    DesignProcess[Design] --> JoistType{Joist Type}
    JoistType --> Reinforced[Reinforced - IS 456:1964]
    JoistType --> Prestressed[Prestressed - IS 1343:1960]
    Reinforcement --> Reinforced & Prestressed

For comprehensive reinforcement and prestressing layouts, consult Appendix A of IS 6061 Part 1.

Appendix BPrecast Hollow Cement Concrete Filler Blocks

Specifications for Precast Hollow Cement Concrete Filler Blocks (IS 6061 Part 1)

Requirements (Clause 3.6 & Appendix B):

  • Blocks must comply with dimensional and strength criteria outlined in Appendix B.
  • Typical block design for 600 mm joist center spacing shown in Fig. 2.
  • Reinforcement is mandatory for spans equal to or exceeding 750 mm between joists.

Dimensions & Features (Fig. 2):

  • Designed for 600 mm joist spacing.
  • Hollow cores reduce weight and enhance thermal insulation.
  • Typical dimensions approximately 230 mm width × 100 mm height × 450 mm length (verify exact sizes in Fig. 2).

Strength Testing (Clause B-2, Table B-2):

  • Minimum testing: two blocks per batch or two per 1000 blocks.
  • Minimum compressive strength around 3.5 MPa (refer to Table B-2).
  • Blocks must maintain specified dimensional tolerances.

Reinforcement (Clause 1.5):

  • For spans ≥ 750 mm, internal reinforcement should be provided inside hollow cores.
  • Reinforcement improves load capacity and reduces cracking risk.

Summary Table:

ParameterSpecification
Typical Block Size~230 × 100 × 450 mm
Joist Spacing600 mm (reinforce if ≥ 750 mm)
Strength Testing2 blocks per batch or 2/1000 tested
Minimum Strength≥ 3.5 MPa (check Table B-2)
Reinforcement RequirementMandatory for spans ≥ 750 mm

flowchart LR
    HollowBlock[Precast Hollow Block] --> JoistSpacing{Joist Spacing}
    JoistSpacing -->|< 750 mm| NoReinforcement[No Reinforcement Needed]
    JoistSpacing -->|≥ 750 mm| ReinforcementNeeded[Provide Reinforcement]
    HollowBlock --> StrengthTesting[Breaking Strength Test]
    StrengthTesting --> TestSamples{Test 2 blocks per batch or per 1000}
    TestSamples --> PassCriteria[Pass if ≥ 3.5 MPa]

Refer to Appendix B and Fig. 2 of IS 6061 Part 1 for exact dimensions and reinforcement specifications.

Popular Questions About IS 6061 PART 1

?What are the recommended dimensions and spacing for precast concrete joists?

Recommended Dimensions and Spacing for Precast Concrete Joists (IS 6061 Part 1):

  • Joist Depth:

    • Up to 4.2 meters span: 150 mm.
    • Between 4.2 and 6 meters span: 200 mm.
  • Joist Width: Uniform width throughout, depending on design requirements.

  • Maximum Span: Should not exceed 6 meters.

  • Spacing: Joists should be positioned at design-specified intervals spanning between supports, typically based on structural loads and filler block dimensions.

  • Design Codes: Structural design must comply with IS 456 for reinforced concrete and IS 1343 for prestressed concrete.


Summary Table

Span (m)Joist Depth (mm)Maximum Span (m)Spacing
≤ 4.2150≤ 6As per structural design
4.2 – 6200≤ 6As per structural design

Loading diagram...

This arrangement ensures uniform load distribution and structural integrity.

?What are the material specifications for hollow cement concrete filler blocks?

Material Specifications for Hollow Cement Concrete Filler Blocks (IS 6061 Part 1):

  • Compressive Strength: Typically minimum 7.5 MPa (75 kg/cm²) at 28 days; exact values detailed in Appendix B.
  • Cement: Ordinary Portland Cement conforming to IS 269 or IS 8112.
  • Aggregates: Fine aggregates meeting IS 383 standards; coarse aggregates must be clean and free from contaminants.
  • Water-Cement Ratio: Maintained between 0.4 and 0.5 for optimal workability and strength.
  • Reinforcement: Required for joist spacing of 750 mm or greater, using steel bars or mesh as per Clause 1.5 B-1.5.
  • Dimensions: Typical block size for 600 mm joist spacing shown in Fig. 2 of IS 6061 Part 1.
  • Testing: Must pass breaking strength tests outlined in Clause 3.6 and Appendix B.

Summary Table

PropertySpecification
Compressive Strength≥ 7.5 MPa (75 kg/cm²)
Cement TypeOPC (IS 269 or IS 8112)
Aggregate QualityClean, IS 383 compliant
Water-Cement Ratio0.4 – 0.5
Reinforcement RequirementFor spans ≥ 750 mm
TestingBreaking strength per Appendix B
Loading diagram...

For precise dimensions and reinforcement details, refer to Appendix B and Fig. 2.

?How should the precast joists be cured and handled to prevent damage?

Based on IS 6061 Part 1, precast joists require careful curing and handling to maintain integrity:

Curing Process:

  • Immediately after demoulding, keep joists moist by water spraying for 24 hours.
  • Once sufficiently strong, transfer joists to curing yards.
  • Maintain continuous moisture for at least seven days post-casting.
  • After curing, store joists in shaded areas, allowing gradual drying over a minimum of three weeks before installation.

Handling and Storage:

  • Lift joists carefully from casting platforms using designer-indicated lifting points.
  • Use temporary supports at specified locations during stacking and transportation.
  • Stack joists on firm, level ground or platforms.
  • When stacking multiple layers, ensure vertical alignment of props.
  • Handle with care throughout storage, transport, and placement to avoid damage.

This procedure promotes strength gain and minimizes cracking or physical damage.

?What type and thickness of topping concrete is required for composite action?

Per IS 6061 Part 1, the topping concrete for composite action with joists should have the following characteristics:

  • Concrete Grade: Structural topping concrete of grade M-150 as per IS 456-1964.

  • Minimum Thickness: 50 mm over the hollow filler blocks.

  • Reinforcement:

    • Minimum 0.15% steel reinforcement along the joist direction.
    • Minimum 0.20% reinforcement across the joists.
    • Reinforcement spacing should not exceed 300 mm.
    • Top reinforcement over supports must be anchored to stirrups projecting from joists.
    • Alternatively, welded wire mesh can be used.
  • Surface Finish:

    • Smooth surface if no subsequent flooring is planned.
    • Roughened surface if additional flooring finishes will be applied to improve bonding.

This ensures effective composite (T-beam) action between the precast joists and the topping slab.

Loading diagram...
?What are the load bearing and support requirements for filler blocks and joists?

According to IS 6061 Part 1, load transfer and support criteria are:

  • Minimum Bearing Length: Filler blocks must rest on joists with a bearing length not less than 25 mm (Clauses 2.2.4 & 1.3).
  • Joist Spacing: Typically arranged at 600 mm centers, with filler blocks spanning between them (Clause 1.4).
  • Block and Joist Profiles: Both should be shaped to ensure proper bearing and load distribution.
  • Joist End Gaps: Spaces between adjacent joists over walls or beams must be filled with masonry or concrete flush with the joist top surface to provide continuous bearing for walls above (Clause 6.3).

Summary Table

ParameterSpecification
Bearing Length on JoistMinimum 25 mm
Joist Spacing600 mm centers
End Gaps Between JoistsFilled flush with masonry/concrete

This ensures stable load transmission from filler blocks to joists and supports.

Loading diagram...