IS 149122001AI Search Enabled✦ AI Generated

Door Closers, Concealed Type (Hydraulically Regulated)
2001 Edition

This standard outlines the specifications for concealed hydraulic door closers designed for vertically hinged doors weighing up to 80 kg. It details the requirements related to design, materials, testing, performance, and marking to ensure efficient automatic closing with adjustable hydraulic damping. The standard is crucial for professionals involved in manufacturing, quality assurance, and installation of these door closers in various building types.

15Sections
64Clauses Indexed
AI Search Ready
2001Edition
Builder HardwareCategory
Alternative search terms: concealed-hydraulic-door-closers-requirements-and-standards-2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 pdf free download, concealed-hydraulic-door-closers-requirements-and-standards-2001 free download pdf, concealed-hydraulic-door-closers-requirements-and-standards-2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001:2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001-2001 PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 (2001) PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 2001 edition PDF, concealed-hydraulic-door-closers-requirements-and-standards-2001 edition 2001 PDF

What This Standard Covers

This standard outlines the specifications for concealed hydraulic door closers designed for vertically hinged doors weighing up to 80 kg. It details the requirements related to design, materials, testing, performance, and marking to ensure efficient automatic closing with adjustable hydraulic damping. The standard is crucial for professionals involved in manufacturing, quality assurance, and installation of these door closers in various building types.

Who Uses This Standard

  • Mechanical design engineers
  • Manufacturers of building hardware
  • Quality assurance inspectors
  • Architects and building planners
  • Civil engineering professionals
  • Facility management staff
  • Procurement managers

Key Topics Covered

Application scope and usage of concealed hydraulic door closers
Terminology for door types and closer orientations
Classification of nominal sizes based on door weight
Material specifications for principal components
Requirements for hydraulic fluids and sealing elements
Standards for construction quality and surface finishes
Installation procedures and mounting techniques
Adjustability of closing speed and timing
Performance evaluation and durability testing methods
Marking, packaging norms, and included accessories
Sampling procedures and conformity assessment
Temperature conditioning and testing protocols
Interchangeability of parts and components
Surface treatment and corrosion resistance measures
Licensing and standard marking requirements

Table of Contents

1Scope and Application
2Referenced Standards
3Terminology and Definitions
5Classification of Nominal Sizes
6Material Requirements
7Fundamental Requirements
8Surface Treatment and Finishing
9Testing Procedures for Door Closers
10Marking Specifications
11Packaging Instructions
12Accessories Provided with Door Closers
13Sampling and Conformity Evaluation
Annex AList of Referenced Indian Standards
Annex BDetailed Testing Procedures
Annex CComposition of the Technical Committee

Popular Questions About IS 14912

?Which materials are authorized for the key components of concealed hydraulic door closers as per the standard?

The standard specifies permissible materials for main parts of concealed hydraulic door closers in Table 2 (Clause 6). These include aluminium alloys for the main body, steel or cast iron for pistons and end plugs, steel for springs, neoprene rubber for valve packing, brass or steel for regulating valves, and mineral oil resistant materials for seals. Hydraulic fluid must be a high-viscosity, all-weather resistant oil conforming to IS 3098. This combination ensures durability, corrosion resistance, and optimal hydraulic performance.

?How can the closing speed of the door closer be adjusted in accordance with this standard?

The closing velocity is regulated via a speed regulating screw located on the valve assembly of the door closer. Each unit is supplied with a fitting key or spanner for this purpose. Turning this screw modifies the flow rate of the hydraulic fluid, thereby adjusting the closing speed. The standard requires that after temperature conditioning, no leakage or defects should be observed, ensuring consistent performance.

?What performance and endurance tests are mandated for conformity certification?

Conformance involves both performance and endurance assessments. Performance tests evaluate construction, finishing, dimensions, interchangeability, and functionality, with sample sizes and acceptance limits based on batch size. Endurance tests require a smaller sample subjected to prolonged operational cycles. Passing all tests is essential for batch acceptance, ensuring the door closers meet reliability and durability standards.

?Does this standard apply to door closers intended for doors heavier than 80 kg or overhead types?

No, this standard specifically applies to concealed hydraulic door closers for vertically hinged doors with a maximum weight of 80 kg. It excludes door closers designed for doors exceeding this weight and overhead types, which are covered under different standards such as IS 3564:1995.

?What are the marking and packaging requirements that manufacturers must adhere to?

Manufacturers are required to mark each door closer clearly with the producer's name or trademark, the type designation (right, left, or universal), size, and serial number. Packaging must be done individually in cardboard or wooden boxes with protective materials like reinforcing boards or straw to prevent damage and moisture ingress during storage and transport. Visual inspections ensure compliance, and use of the BIS Standard Mark necessitates licensure per the Bureau of Indian Standards regulations.

Need Detailed Clause Answers?

Ask AI about any clause, requirement, or provision in IS 14912. Get instant, clause-cited responses powered by our indexed library.

Free tier includes 150 queries (50 AI + 100 Reference) · No credit card required